REVISIONS
<br /> DESCRIPTION DATE:
<br /> V LAYER OF INSULATI❑N HOOD CORNER Al
<br /> FACTORY INSTALLED IN 3TPI HANGING ANGLE
<br /> 3,00" END STANDOFF MEETS GRADE 5 (M(MINIMUM) (HARDWARE BY INSTALLER)
<br /> 55 9/16" 28 3/8" 55 9/16" 55 9/16" 28 3/8" 55 9/16" 0" REQUIREMENTS CLEARANCE STEEL HEX NUTS. Q
<br /> T❑ COMBUSTIBLE SURFACES,
<br /> 1/2' GRADE 5
<br /> (MINIMUM) STEEL Q
<br /> FLAT WASHER.
<br /> 3' 4 3/16" 4 3/16" 4 3/16" 4 3/16" 3"
<br /> O o O O O
<br /> 12" I STEEL ALL—THREAD,12"
<br /> 2 1/4" i 2 1/4" 2 1/4" i 2 1/4" GRADE 5 (MINIMUM)
<br /> a
<br /> I�
<br /> 018" 018"
<br /> 1/2' — 13 TPI
<br /> GRADE 5 (MINIMUM)
<br /> STEEL HEX NUT. U
<br /> U
<br /> 1/2' GRADE 5 HOOD CORNER
<br /> (MINIMUM) STEEL HANGING ANGLE
<br /> FLAT WASHER. (WEIGHT BEARING m
<br /> ANCHOR POINT
<br /> FOR HOOD).
<br /> M O
<br /> 60" U.L, LISTED RECESSED ROUND U.L, LISTED RECESSED ROUND 60" 1/2• GRADE 5 U
<br /> LED FIXTURE AND LED LIGHT. LED FIXTURE AND LED LIGHT, FLATWASHER,LATWASHEII >
<br /> 1/2' — 13 TPI I
<br /> GRADE 5 (MINIMUM)
<br /> STEEL HEX NUTS, III _v
<br /> I I
<br /> ASSEMBLY INSTRUCTI❑NS II
<br /> J_
<br /> Q
<br /> UPiL17411 2 1/4' 2 1/4' 2 1/4' HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI I w
<br /> CABI ET. GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING
<br /> 1/4" 28" 28" 2 O O 28" 2 28' 28" 2 1/ �
<br /> ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 I
<br /> roi o ` ®o o ` ®0 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI ")
<br /> T TT T
<br /> GRADE 5 (MINIMUM) HEX NUTS AS SHOWN, MUST USE c„
<br /> _ _ _ _ DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING a,
<br /> 18~ 1 ~---------- ----- 12'— -------- ----- - 12'---------- ----- - 12'— 73-W
<br /> - - 1 " - X12 ----- ---- ----- --- X12 18' ANGLES AND ABOVE CEILING ANCH❑RS. MAINTAIN 1/4" OF--- � -- --- --- � -- -r•1~— -- -- �~— -- --- i••��"---------- � EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE
<br /> p 9" 9" 9" 9" 9J— 9'L 9J— 9� ALL HEX NUTS TO 57 FT-LBS. Q
<br /> 2" 2 V o
<br /> 0
<br /> N
<br /> 2 1/4" 2 1/4' L
<br /> 72" 72" 72" 72" �
<br /> V �
<br /> 19 1/ 39" I 39" I 39" 19 1/4" 36 1/4" I 36" I 36 1/4" I z
<br /> O
<br /> 1 12' 0'NOM,/12' 0.00'OD. 12' 0'NOM,/12' 0.00"OD. 3" d
<br /> CD
<br /> 13'-0.00" OVERALL LENGTH 12'-3,00" OVERALL LENGTH
<br /> rn
<br /> Q
<br /> 25'-3.00' OVERALL LENGTH L)
<br /> m
<br /> cu
<br /> E
<br /> PLAN VIEW — HOOD #1 PLAN VIEW — HOOD #2
<br /> 12' 0.00" LONG 603OND-2—PSP—F 12' 0.00" LONG 6030ND-2—PSP—F
<br /> NOTE: ADDITI❑NAL HANGING ANGLES PROVIDED FOR HODS 12' AND LONGER, NOTE; ADDITI❑NAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER, m
<br /> FULL LENGTH RECESSED ROUND LED FIXTURE AND LED LIGHT, RECESSED ROUND LED FIXTURE AND LED LIGHT, �
<br /> 1/2' — 13 TPI HANGING ANGLE 3500 K WARM OUTPUT, 3500 K WARM OUTPUT, U
<br /> GRADE 5 (MINIMUM) (HARDWARE BY INSTALLER)
<br /> STEEL HEX NUTS. N
<br /> •L
<br /> 1/2' GRADE 5
<br /> (MINIMUM) STEEL
<br /> FLAT WASHER. co
<br /> FIELD WRAPPER 10.00" HIGH FIELD WRAPPER 10,00" HIGH
<br /> (SEE HOOD ❑PTI❑NS TABLE). (SEE HOOD OPTIONS TABLE),
<br /> 1/2' — 13 TPI 60" 60"
<br /> GRADE 5 (MINIMUM)
<br /> STEEL ALL—THREAD. EXHAUST RISER. EXHAUST RISER,
<br /> � ATTACHING PLATES. � ATTACHING PLATES,
<br /> 1/2' — 13 TPI
<br /> GRADE 5 (MINIMUM) SUPPLY RISER WITH SUPPLY RISER WITH
<br /> HANGING ANGLE,
<br /> STEEL HEX NUT. FULL LENGTH VOLUME DAMPER, HANGING ANGLE. VOLUME DAMPER.
<br /> 1/2' GRADE 5HANGING ANGLE EE HO❑D TA E. EE HOOD TA E.
<br /> (MINIMUM) STEEL (WEIGHT BEARING 23.5% OPEN STAINLESS 23.5% OPEN STAINLESS
<br /> FLAT WASHER, ANCHOR POINT " STEEL PERFORATED PANEL, " STEEL PERFORATED PANEL.
<br /> FOR HOOD). 2 3/4 2 3/4
<br /> 20" CAPTRATE S❑L❑ 20" CAPTRATE S❑L❑
<br /> FILTER WITH HOOK, 6~ FILTER WITH HOOK.
<br /> 6"
<br /> 1/2' GRADE 5 3" INTERNAL STANDOFF, 18 3" INTERNAL STANDOFF. 18"
<br /> (MINIMUM) STEEL
<br /> FLAT WASHER.
<br /> 1/2' — 13 TPI 30" N❑M, 30~ NOM.
<br /> GRADE 5 (MINIMUM)
<br /> STEEL HEX NUT. 24" 24'
<br /> ASSEMBLY INSTRUCTI❑NS
<br /> IT IS THE RESPONSIBILITY IT IS THE RESPONSIBILITY
<br /> HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI OF THE ARCHITECT/OWNER TO OF THE ARCHITECT/OWNER TO
<br /> GRADE 5 (MINIMUM) ALL-THREAD SANDWICH HANGING ENSURE THAT THE HOOD CLEARANCE ENSURE THAT THE HOOD CLEARANCE
<br /> FROM LIMITED-COMBUSTIBLE FROM LIMITED-COMBUSTIBLE >
<br /> ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 AND COMBUSTIBLE MATERIALS AND COMBUSTIBLE MATERIALS
<br /> (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI IS IN COMPLIANCE WITH IS IN COMPLIANCE WITH
<br /> GRADE 5 (MINIMUM) HEX NUTS AS SHOWN, MUST USE LOCAL CODE REQUIREMENTS, LOCAL CODE REQUIREMENTS.
<br /> DOUBLED HEX NUT CONFIGURATION ABOVE CEILING (� QJ Lo
<br /> ANCHORS, SINGLE HEX NUT BENEATH HANGING ANGLE IS I—I
<br /> ACCEPTABLE FOR FULL LENGTH HANGING ANGLES, ___
<br /> MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM GREASE WITH REMOVABLE CUP WITH REMOVABLE AIN GREASE DRAIN
<br /> N Z
<br /> HEX NUT, TORQUE ALL HEX NUTS TO 57 FT-LBS, 48.0" MAX. 48.0" MAX, Q: Q
<br /> SUPPLY PLENUM
<br /> 1/2' — 13 TPI HANGING ANGLE
<br /> GRADE 5 (MINIMUM)
<br /> STEEL HEX NUTS. (HARDWARE BY INSTALLER) 0
<br /> 1/2' GRADE 5 BACKSPLASH 8 0 HIGH
<br /> (MINIMUM) STEEL X 303,00" LONG
<br /> FLAT WASHER. Ll u
<br /> 80" 80" 80" u3 �
<br /> 1/2' — 13 TPI
<br /> GRADE 5 (MINIMUM)
<br /> STEEL ALL—THREAD,
<br /> 1/2' — 13 TPI
<br /> GRADE 5 (MINIMUM) 4"
<br /> STEEL HEX NUT. SUPPLY PLENUM QUIF MENT EQUIPMENT
<br /> HANGING ANGLE Y ❑ HERS. BY OTHERS,
<br /> 1/2' GRADE 5 (WEIGHT BEARING DATE: 7/19/2021
<br /> (MINIMUM) STEEL ANCHOR POINT
<br /> FLAT WASHER. FOR SUPPLY
<br /> PLENUM). DWG.#:
<br /> (MINIMUM)GRADE STEEL 20" 4995421
<br /> FLAT WASHER, r 4 1/2" DRAWN
<br /> 1/2' — 13 TPI L
<br /> GRADE 5 (MINIMUM) GAS CHASE CUTOUT BY: Danny g
<br /> STEEL HEX NUT.
<br /> (FOR GAS AND POWER LINES),
<br /> 21" SCALE:
<br /> ASSEMBLY INSTRUCTI❑NS LEFT VERTICAL END PANEL 27' 3/4" = 1 '-0"
<br /> WITH ADJUSTABLE LEGS,
<br /> HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI SECTION VIEW — MODEL 6030ND-2—PSP—F SECTION VIEW — MODEL 6030ND-2—PSP—F MASTER DRAWING
<br /> GRADE 5 (MINIMUM) ALL-THREAD, SANDWICH HANGING HOOD — #> HOOD — #2
<br /> ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5
<br /> (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI
<br /> GRADE 5 (MINIMUM) HEX NUTS AS SHOWN, MUST USE
<br /> DOUBLED HEX NUT CONFIGURATION ABOVE CEILING
<br /> ANCHORS, SINGLE HEX NUT BENEATH HANGING ANGLE IS
<br /> ACCEPTABLE FOR PSP HANGING ANGLES, MAINTAIN 1/4" OF
<br /> EXPOSED THREADS BENEATH BOTTOM HEX NUT, TORQUE SHEET NO.
<br /> ALL HEX NUTS TO 57 FT-LBS,
<br /> 2
<br />
|