My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1110
>
1600 - Food Program
>
PR0161074
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:25:05 PM
Creation date
11/10/2022 2:17:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161074
PE
1625
FACILITY_ID
FA0000794
FACILITY_NAME
7-ELEVEN INC # 41530
STREET_NUMBER
1110
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21821023
CURRENT_STATUS
02
SITE_LOCATION
1110 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IN ACCORDANCE WITH NEC 240.86(C), SUM OF MOTOR FULL-LOADCURRENTS WITHIN EACH PANELBOARD DOES NOT EXCEED 1% OF THELOWEST INTERRUPTING RATING OF THE BRANCH CIRCUIT'S BREAKERSWITHIN EACH PANELBOARD.BREAKERS RATED 10K AIC - 10,000 x .01 = 100ABREAKERS RATED 22K AIC - 22,000 x .01 = 220AELECTRICAL CONTRACTOR TO AFFIX A PERMANENT LABEL AT SERVICEENTRANCE IN ACCORDANCE WITH NEC SECTION 110-22 (C), MARKINGSHALL READ :"CAUTION - SERIES COMBINATION SYSTEM RATED 65,000AMPS, IDENTIFIED REPLACEMENT COMPONENTS REQUIRED."ALL CIRCUIT BREAKERS IN PANELBOARDS "A", "B", "L", "S" SHALL BESERIES RATED FOR THE AVAILABLE SHORT CIRCUIT CURRENT - 65,000AMPS MINIMUM. DISTRUBUTION BREAKERS SHALL PROTECT ALLDOWNSTREAM PANELBOARD BREAKERS.SQUARE D - SERIES RATING - 65,000 AICMAIN BREAKERSBREAKER TYPE2-POLE3-POLE1-POLE2-POLE3-POLESUB PANEL BREAKERSBREAKERTYPEHG15-150AQO(B)10K AIC15-70A15-125A15-100AN/AN/A35-150AQO(B)VH22K AICJG150-250AQG70-225AQO(B)10K AICQO(B)VH22K AIC15-70A15-125A15-30AN/A35-150A150A240V MAX.240V MAX.rev. 7/2013LG400AQO(B)10K AICQO(B)VH22K AIC15-70A15-125A15-100AN/A35-150A150A240V MAX.ONE-LINE NOTES1.CLEARLY LABEL MAIN ELECTRICAL SERVICE DISCONNECT(S)PER NEC.2.PROVIDE ARC FLASH LABELING AS REQUIRED PER NEC 110.163.AMPACITY OF ALL CONDUCTOR SIZES SHOWN IS BASED ON75°CRATED TERMINATIONS AND CONDUCTORS WITH 75°CTYPE INSULATION. CONTRACTOR SHALL FIELD VERIFYTERMINATION RATINGS OF ELECTRICAL EQUIPMENT ANDADJUST CONDUCTOR SIZES AS REQUIRED PER NEC 110.14(C)4.ALL NEW OVERCURRENT DEVICES SHALL BE INSTALLED INACCORDANCE WITH THE SERIES RATING TABLE OF IDENTIFIEDCOMPONENTS.5.ALL NEW PANELS ARE PROVIDED BY 7-ELEVEN, INSTALLED BYGC. ALL PANELBOARD FEEDERS TO BE PROVIDED ANDINSTALLED BY GC.6.G.C. TO PROVIDE AND INSTALL UTILITY METER AND NEWELECTRICAL SERVICE ENTRANCE. COORDINATE EXACTREQUIREMENTS WITH POWER UTILITY PRIOR TOCOMMENCEMENT OF WORK.7.ELECTRICAL GC TO COORDINATE ALL FUEL REQUIREMENTSWITH FUELING GC. THE ELECTRICAL GC WILL PROVIDE ALLNECESSARY CONDUITS, SEAL-OFFS, TROUGHS ANDRACEWAYS FROM THE ELECTRICAL ROOM OR PANEL AREA TOTHE EXTERIOR OF THEBUILDING, BUT NOT TO EXCEED 10FEET FROM THE EXTERIOR BUILDING EDGE. ALL OTHEREQUIPMENT, WIRE, LABOR FOR THE COMPLETION OF THEFUEL SYSTEM TO BE PROVIDED BY THE FUELING GC.8.ELECTRIC METER ROOM DOOR SHALL HAVE SCHLAGE LOCK,KEYED TO RIVERSIDE PUBLIC UTILITIES' MASTER KEY , OR SHALLHAVE A DOUBLE HASP. WORKING SPACE NEAR THE METER PANELPER 2010 NEC 110-26 IS REQUIRED. THE MOUNTING HEIGHT OFELECTRIC METERS SHALL BE BETWEEN 48 AND 75 INCHES ABOVETHE WORKSPACE FLOOR AREA REQUIRED BY NEC 110-26.ELECTRIC ROOM DOOR OPENING SHALL EXTEND TO OR ABOVETHE FULL HEIGHT OF THE SWITCHGEAR.9.THE MAIN ELECTRIC PANEL SWITCHGEAR SHALL CONFORM TO THEEUSERC / CITY OF RIVERSIDE REQUIREMENTS. PRIOR TOMANUFACTURING, THE MAIN ELECTRIC PANEL SWITCHGEARDRAWINGS SHALL BE APPROVED BY THE CITY OF RIVERSIDE,PUBLIC UTILITIES ELECTRIC DIVISION. SEND ORIGINAL APPROVALDRAWINGS FOR APPROVAL TO: ELECTRIC ENGINEERING 3750UNIVERSITY AVE., THIRD FLOOR, RIVERSIDE CA 92522 OR VIA EMAIL.NOTE: NOT ALL SYMBOLS ARE USEDSYMBOL LEGEND(*)(L)(B)(G)(+)INDICATES BLOCKING DEVICEINDICATES GFCI BREAKERINDICATES 30mA TRIP GFCI BREAKERINDICATES LOCKING DEVICEINDICATES EXISTING TO EXTENDINDICATES NEW(N)BREAKERFUSESWITCHCURRENT TRANSFORMER (CT)INDICATES EXISTING(E)Job#: <br />Scale: <br />Date: <br />Drawn By: <br />Checked By: <br />Rev. #Date DescriptionSHEET:7-ELEVEN, INC. <br />3200 HACKBERRY, IRVING, TEXAS 75063 <br />SE1237 <br />7-ELEVEN 1046249 <br />1110 MAIN ST <br />MANTECA, CA 95336 <br />MS <br />RES <br />10/29/2020#2/0 PER N.E.C. 250.52 (A) (7)E1.1PANEL SCHEDULES <br />AND ONE-LINE DIAGRAM#2/0 PER N.E.C. 250.52 (A) (4)#2/0 PER N.E.C. 250.52 (A) (1)#2/0 PER N.E.C. 250.52 (A) (2)#6 PER N.E.C. 250.52 (A) (5)#4 PER N.E.C. 250.52 (A) (3)
The URL can be used to link to this page
Your browser does not support the video tag.