Laserfiche WebLink
PIPE TRENCH DETAIL SCALE: NTS STANDARD PIPE POLLARD DETAIL NFPA 30/30A SCALE: 1" = 1'-0" <br /> / ALTERNATE POST POLLARD DETAIL - CALIFORNIA SCALE: 1 = 1'-0" CLIENT: <br /> 6"0 STRAIGHT PIPE <br /> 6" WIDE DETECTABLE UNDERGROUND 4"� U-SHAPED BOLLARD 91 BOLLARD FILLED 91 <br /> bp <br /> MARKING TAPE BURIED 6"-12" BELOW FILLED WITH CONCRETE WITH CONCRETE <br /> FINISHED GRADE: EMPIRE x¢31-143 CONCRETE PAVING (STANDARD DEPTH) (EXTENDED DEPTH) <br /> PAINT TOP 1/3, BP PAINT TOP 1/3, BP ; <br /> YELLOW YELLOW ' <br /> x <br /> PEA GRAVEL ° \� I o <br /> BACKFILL / °&° I DISPENSERS ATo <br /> p°° \ \ 9 f9 <br /> PAINT BOTTOM 2/3, 3 -6 GRADE OR ON 6" PAINT BOTTOM 2/3, 3$-C —DISPENSERS AT <br /> 2" OR 3" FRP ° BP PEARL 99 ISLAND BP PEARL <br /> x °° \ <br /> VAPOR RETURN 14 14 4"0 DRIVE SLAB 6"ib DRIVE SLAB <br /> LINE (NOTE: <br /> 6 s" DOUBLE WALL 2" INSIDE 3" D.W. tr: r-- a:° q <br /> 6" 12" 10" 6" <br /> ONLY WHERE FRP OR 1-1/2" OR ° . a ° ° q.. <br /> REQUIRED) 2 FLEXIBLE \\/\\/\\/\\/\\ /\\/\\/\\/\\/\\l\\K <br /> PRODUCT PIPING \\\i\\i\�j/j\j\j a.' 4. \ <br /> VAPOR RECOVERY IN COMBINED VAPOR RECOVERY <br /> SEPARATE TRENCH OPTION AND PRODUCT PIPING TRENCH <br /> NATIVE <br /> S01 L \\ <br /> NATIVE SOIL <br /> //\\// / /\//\\//\\ <br /> NOTE: NOTE: \\�\ \ \✓i\% \%\\% //\ \//\ \\j\�jj�\' <br /> 0 IN COMBINED TRENCH, MIN. 12 2,500 PSI CONCRETE FOUNDATIONS <br /> FOR ILLUSTRATION PURPOSES, A BLENDING BETWEEN STAGE II & PRODUCT SHOWN ARE MINIMUM REQUIREMENTS; 1'-3"O MIN. sp wm cffiff FROM=LLC <br /> GASOLINE OPTION IS SHOWN. FOR A COMBINED PIPING (C.L.) LOCAL BUILDING CODES OR FROST LINE <br /> DIESEL OPTION, ADDITIONAL PIPING IS REQUIRED. I MAY REQUIRE GREATER DEPTH 2,500 PSI CONCRETE FOUNDATIONS SHOWN ARE <br /> XX IND TES ITEMS FOUND OR MINIMUM FROST LINE MAY REQUIRE LOCAL CODES <br /> QUIREGREATER DEPTH <br /> ON MATERIALS LIST SHEETS <br /> 2012 NFPA 30A FIRE CODE SECTION 6.3.4 REQUIREMENTS FOR DISPENSING DEVICES: 2010 CA FIRE CODE SECTION 2203.1.1 PROTECTION OF DISPENSING DEVICES: <br /> DISPENSER SUMP CROSSOVER PIPING DETAIL FOR FRP SCALE: NTS DISPENSING DEVICES SHALL BE MOUNTED ON A CONCRETE ISLAND OR SHALL BE OTHERWISE WHERE DISPENSING DEVICES ARE MOUNTED AT GRADE, THEY SHALL BE PROTECTED AT EACH END F <br /> BE PROTECTED AGAINST COLLISION BY MEANS ACCEPTABLE TO THE AUTHORITY HAVING WITH A MINIMUM OF TWO CONCRETE FILLED STEEL POSTS, 6 INCHES IN DIAMETER, HAVING A <br /> JURISDICTION........... MINIMUM 3 FEET DEEP FOOTING NOT LESS THAN 15 INCHES IN DIAMETER, AND PROJECTING ' � <br /> 2" FRP VAPOR RETURN 4 ABOVE GRADE AT A MINIMUM OF 3 FEET AND BE LOCATED NOT LESS THAN 4 FEET NOR MORE <br /> LEG THAN 5 FEET FROM FUEL DISPENSERS OR POINT OF SALE DEVICES, OR EQUIVALENT MEANS <br /> TO OTHER NOTE: APPROVED BY THE CHIEF. ' <br /> CROSSOVER DROPS FROM DISPENSERS THIS BOLLARD AND FOUNDATION SATISFIES BOTH <br /> EACH DISPENSER CONSTRAINED & NON—CONSTRAINED SOIL 2010 CA FIRE CODE SECTION 2206.7.3 MOUNTING OF DISPENSERS: <br /> CONDITIONS. USE THIS DESIGN IN JURISDICTIONS DISPENSING DEVICES EXCEPT THOSE INSTALLED ON TOP OF A PROTECTED ABOVE GROUND TANKS <br /> 2" INSIDE 3" FRP THAT FOLLOW NFPA 30/30A. THAT QUALIFIES AS VEHICLE IMPACT RESISTANT, SHALL BE PROTECTED AGAINST PHYSICAL <br /> PRODUCT PIPING 4 4 DAMAGE FROM VEHICLES BY MOUNTING ON A CONCRETE ISLANDS 6 INCHES OR MORE IN HEIGHT, <br /> OR SHALL BE OTHERWISE BE SUITABLY PROTECTED IN ACCORDANCE WITH SECTION 312.............. 18215 72ND AVENUE SOUTH <br /> CROSSOVERS DROPS AT KENT, WA 98032 <br /> MAIN HEADERS (TYP.) .0 NOTE: THIS DETAIL TO BE USED WHEN DISPENSERS ARE MOUNTED AT GRADE (425)251-6222 <br /> $, OR WHEN THE DISPENSER ISLANDS ARE LESS THAN 6 INCHES IN HEIGHT (425)251-8782 FAX <br /> TO TANKS g9jNo" NOTE: THIS DETAIL TO BE USED WHEN DISPENSERS ARE MOUNTED AT GRADE <br /> OR WHEN THE DISPENSER ISLANDS ARE LESS THAN 6 INCHES IN HEIGHT CML ENGINEERING, LAND PLANNING, <br /> SURVEYING, ENVIRONMENTAL SERVICES <br /> 39_0,9 q -09f 4.'-0" NO. DATE REVISION DESCRIPTION <br /> 40 ool <br /> 40 <br /> j r 3'-8" (TYP ) 3'-8" i 3'-8" (TYP.) I <br /> 10, <br /> >9 TO OTHER 1 a 1 t W a <br /> 3 FRP VAPOR RETURN 48 DISPENSERS \ I I, s \ \ s s <br /> MANIFOLD TO TANKS � NOTE: <br /> XX INDICATES ITEMS FOUND I N <br /> 4 <br /> ON MATERIALS LIST SHEETS I w ADDITIONAL BOLLARD <br /> I 5 ESLOPE <br /> INSTALLED ONLY IF I PEI I SLOPE 5 <br /> ALTERNATE FIRE EXTINGUISHER FOR DISPENSER AREA INSTALLATION DETAILS SCALE: 1" - 1'-0' i I REQUIRED BY I I I Q <br /> ADDITIONAL BOLLARD I I I I `� AUTHORITY HAVING <br /> INSTALLED ONLY IF o L —— ——�— — —J JURISDICTION w zQ <br /> REQUIRED BY �� o ^ <br /> AUTHORITY HAVING I I z o s <br /> CABINET: KID-FXC-24 �`'J a <br /> z0 9 <br /> w �U 9 <br /> WITH BREAKABLE GLASS, JURISDICTION ( � 7 -' 0 <br /> 24"x10"x6" OR EQUAL 4'°x4"xY�" TUBE STEEL 1 / w <br /> COLUMN <br /> uiTYPICAL DISPENSER <br /> FIRE EXTINGUISHER: 0 L) TYPICAL DISPENSER 7i <br /> KID-10-460 10# (ACTUAL FOOTPRINT MAY VAR ) <br /> (ACTUAL FOOTPRINT MAY VARY) <br /> 4:A-60-BC OR EQUAL DISPENSERS AT GRADE (PRIMARY CHOICE) DISPENSERS AT GRADE (PRIMARY CHOICE t2 <br /> SEAL: <br /> Q?,OFESS/0 <br /> MOUNT FIRE EXTINGUISHER NOTE: THIS DETAIL TO BE USED WHEN DISPENSERS ARE MOUNTED ON ISLANDS AND NOTE: THIS DETAIL TO BE USED WHEN DISPENSERS ARE MOUNTED ON ISLANDS ANDTE'� <br /> CABINET TO TUBE STEEL COLUMN WHEN THE DISPENSER ISLANDS ARE 6 INCHES OR MORE IN HEIGHT WHEN THE DISPENSER ISLANDS ARE 6 INCHES OR MORE IN HEIGHT <br /> Y" ANGLE WELD AROUND 3'-8" (TYP.) 3'-8" (TYP.) i 3'-8" (TYP.) 3'-8" (TYP.) rm <br /> lop 8 s <br /> PERIMETER OF TUBE STEEL <br /> TYPICAL DISPENSER _ \ TYPICAL DISPENSER <br /> 8"x8" Y4" STEEL BASE (ACTUAL FOOTPRINT MAY VARY) (ACTUAL FOOTPRINT MAY VARY) <br /> 5/"Ox12"L HILTI EPDXY SET PLAT <br /> THREADED FASTENERS i i 4 (0 OF* CA10i <br /> I <br /> GRADE <br /> i� <br /> wz <br /> a O � O� <br /> bi w�J <br /> NOTE: d d z o z 0 \ <br /> NOTE: WHEN DISPENSERS ARE v NOTE: WHEN DISPENSERS ARE <br /> INSTALL FIRE EXTINGUISHER � �� �� �� �� � �� �� �� ��\ Iw— INSTALLED ON ISLANDS USE `\ � � INSTALLED ON ISLANDS AS SHOWN IN DETAILS, DO A��������� �������� z 99 z D USE \ <br /> NOT MOUNT TO DISPENSER. � ���\�/������� ����� ���\� u STANDARD LENGTH NFPA 4 s� <br /> w STANDARD U—SHAPED BOLLARD SHAPED BOLLARD <br /> � <br /> CONCRETE FORECOURT DISPENSERS ON ISLAND (SECONDARY CHOICE DISPENSERS ON ISLAND (SECONDARY CHOICE <br /> DEVELOPMENT INFORMATION: <br /> CANOPY COLUMN SPACING & TYPICAL FIRE EXTINGUISHER LOCATIONS AT DISPENSER AREA FOR DOMINO 6 CANOPY ( NEST OF ROCKIES) ARCO <br /> 3000 am/pm <br /> FUEL, CANOPY <br /> 9'-10" 32'-0" id ro vv PD9a <br /> 40 <br /> SITE ADDRESS: <br /> cn <br /> T {. o KWWAY <br /> N AL CA <br /> w ISPENSER THIS <br /> SHOIWS <br /> FAMffY 0 TBD <br /> DISPENSERS AT INSTALL CABINET --® <br /> o GRADE ON CANOPY DESIGNED BY: AwANCE Z&DM: <br /> AL <br /> PIC UNIT INST LL CABINET PIC UNIT <br /> COLUMN (TYP.) CHECKED BY: BP REPM: <br /> o a- w (TYP.) Ofd, ANOPY (TYP.) oV <br /> w C�, MN (TYP.) DRAM BY: ALLIANCE PM: <br /> AL <br /> THIS SIDE ON: PRO,kECT NO: <br /> x <br /> SHOWS 17223 17223 <br /> z DISPENSERS ON 114/20 <br /> 1.1 a ❑ T ISLANDS ❑ DRAVING TITLE: <br /> x � <br /> o ISPENSER <br /> ISCELLA EOUS DETAILS <br /> N 0) <br /> r I � <br /> r I BUILDING SIDE <br /> SHEET NO: <br /> i� <br /> NOTE: RECOMMENDED BMP <br /> ACTUAL NUMBER OF FIRE EXCEPT FOR WHERE REQUIRED BY <br /> EXTINGUISHERS TO MEET AUTHORITY HAVING JURISDICTION <br /> 6 CANOPY W/ H-FRAME DISPENSERS LOCAL REQUIREMENTS GiiOE,5 <br /> SCALE: 1" = 10'-0" <br />