My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
1600 - Food Program
>
PR0542138
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/9/2023 5:17:38 PM
Creation date
1/12/2023 8:27:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0542138
PE
1617
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\lsauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VENT STACK DETAILS WITH VEEDER—ROOT CARBON CANISTER VAPOR POLISHER TYPICAL DOUBLE WALL SCALE: 1" CLIENT: <br /> 10 1/2- 10 1/2" boA B 23 PRESSURE VACUUM VENT PRESSURE VACUUM VENT 23 p <br /> CAPS (SEE NOTE BELOW) CAPS (SEE NOTE BELOW) <br /> Y <br /> SERVICEABLE VAPOR SENSOR GROUP PRESSURE VACUUM VENT CAP <br /> 23 (SEE NOTE BELOW) 2 PIN CONNECTOR OF <br /> CABLE (FROM KIT) ATTACHES <br /> TO CCVP VALVE <br /> CANISTER SUPPORT BRACKET <br /> AND FASTENERS (FROM KIT) <br /> 1 0 I VEEDER-ROOT CARBON CANISTER 67 CANISTER SUPPORT STUDS <br /> ® I VAPOR POLISHER W/ NUTS (3 EA SIDE) <br /> CANISTER WEIGHT APPROX. 70 LBS. <br /> SEE FOUNDATION DESIGN CRITERIA ( VEEDER-ROOT CARBON CANISTER <br /> BELOW I VAPOR POLISHER <br /> INSTALL ONLY ON THE 87-OCTANE CANISTER WEIGHT APPROX. 70 LBS. <br /> CANISTER SUPPORT BRACKET VENT RISER. DO NOT INSTALL ON 67 SEE FOUNDATION DESIGN CRITERIA <br /> AND FASTENERS (FROM KIT) DIESEL RISER IF EXISTING BELOW <br /> INSTALL ONLY ON THE 87-OCTANE <br /> ° .x CANISTER SUPPORT STUDS W/ w VENT RISER. DO NOT INSTALL ON <br /> NUTS (3 EACH SIDE) \ EXPLOSION PROOF J-BOX DIESEL RISER IF EXISTING <br /> p <br /> Lo MOUNTED TO POST 18g <br /> ARCO <br /> cn CORD GRIP (FROM KIT) <br /> 2" U-BOLTS o o _ _ CF=pEp rm camu mom= <br /> p II I II oo II I <br /> 2 ( I I I I <br /> 2" VENT PIPE EXTENSION MANUFACTURER SUPPLIED 11 1 I I 1 I ( I H <br /> MOUNTING TUBING <br /> I I Z GROUPI I I I �— o I I z <br /> INSTALLING CANISTER ONTO BRACKET I I I I I I I ww m <br /> °° o ~ w I I I I 89 MOUNTED PROOF J-BOX <br /> D TO POST i <br /> w w � �, <br /> ¢z 1 11 MANUFACTURER SUPPLIED , <br /> w I I I <br /> N = <br /> o a MOUNTING TUBING <br /> 2" REDUCING TEE I I I I Lj: z w w w o <br /> CANISTER OPERABILITY TEST PORT I 2" SCH. 40 GALV. STEEL I I `'� m J < Lu <br /> No � w � <br /> `MAINTAIN CLEARANCE INA I VENT RISER PAINT TO 8 I I ¢ o J o I I I I �C� <br /> DIRECT LINE, TO ALLOW FOR MATCH SITE CONDITIONS > N u � 0 U �p � ��©�� <br /> CONNECTION OF TESTING <br /> APPARATUS. I Q � :21 =w " <br /> w I I I "' �,v a< cn 2 SCH. 40 GALV. STEEL <br /> 3-WAY LOCKING BALL VALVE I I ( cV) FASTEN VENT RISER TO FRAME W/ w ry o N I ( 18 VENT RISER PAINT TO 18215 72ND AVENUE SOUTH <br /> =w w <br /> TO BE LOCKED IN OPEN I I I z 2 BRONZE U-BOLT, 3/8"0 HOLE I I I I < � 71 I I I I MATCH SITE CONDITIONS KENT, WA 98032 <br /> POSITION IN NORMAL OPERATING / cn = I I I I <br /> O W LOCK WASHER HEX NUT. TEST � N � _ (425)251-6222 <br /> MODE. z �= EACH RISER FOR ELECTRICAL �o w o FASTEN VENT RISER TO FRAME W/ <br /> I I I CONTINUITY TO VENT RACK TYP. I) l) F �_ 0 0 2" BRONZE U-BOLT, 3/8"0 HOLE (425)251-8782 FAX <br /> BRANCH CONNECTION FROM z w ov ( ) I °II I°II a cn = v w II°II °II W/ LOCK WASHER HEX NUT. TEST CML ENGINEERING, LAND PLANNING, <br /> ' VENT RIDER MUST BE INSTALLED II II 11 011 EACH RISER FOR ELECTRICAL <br /> IJJJ o w m v pSURVEYING, ENVIRONMENTAL SERVICES <br /> LEVEL OR SLOPED BACK TO THE - I- _ry o (l 1I (J_II CONTINUITY TO VENT RACK (TYP.) <br /> TANKS I o _j N uj 2 TEE WITH 1/4 TEST I I I `L_ -' <br /> U z WO w Q NO. DATE REVISION DESCRIPTION <br /> w z PORT FITTING AND 1/4" = v <br /> s m w PLUG (TYP.) <br /> I I - a I I 2" TEE WITH 1/4" TEST I <br /> 2" SCH. 40 GALVANIZED STEEL 8 I I o I I BOLTED GROUND CONNECTION TO- <br /> EI I I PORT FITTING AND 1 4" z <br /> RISER. PAINT PER SPECS (TYP.) I I < w 2-IN-1 SENSOR 1 VENT RACK / <br /> > �_ BOX ( I I ( 1 PLUG (TYP.) 3 <br /> 2" TEE WITH 1/4" TEST PORT I I = '1 ( I I I #4 BARE STRANDED CU <br /> cD < EXPLOSION PROOF J-BOX ( ( I GROUND WIRE TO TANK I I I 1 2-IN-1 SENSOR a <br /> FITTING AND 1/4" PLUG (TYP.) I ( I = MOUNTED TO POST 189 I ( FIELD GROUND ROD I I I BOX 5 <br /> I I I BOLTED GROUND CONNECTION TO <br /> SEAL OFF 191 <br /> I � I I I VENT RACK I I I I 89 EXPLOSION PROOF J-BOX <br /> MOUNTED TO POST Q <br /> x I I I 2" OPENINGS WATERTIGHT <br /> 189 EXPLOSION PROOF INSTALL (1) 1" CONDUIT <br /> 2-IN-1 SENSOR 8 I I COMPRESSION PASS THRU (TYP.) 1 I 1 191 SEAL OFF s <br /> 1 J-BOX MOUNTED TO W/ PULL ROPE FOR <br /> BOX ( POST FUTURE TANK DIAGNOSTIC I I MANOMETER HOUSINGINSTALL I I 1 <br /> MANOMETER ( I <br /> REQUIREMENTS <br /> MTORING ROUTE TOPANEL IN I I I I F8 CONDUIT(W 1PULL <br /> HOUSING <br /> 191 SEAL OFF BUILDING <br /> 1 HYDROSTATIC MONITOR SENSOR I I I ROPE FOR FUTURE �° <br /> — — — — — ( I FOR DOUBLE WALL VENT I I — — — — — I I TANK DIAGNOSTIC <br /> HYDROSTATIC MONITOR SENSOR — — — — I°I — — — — — — — — — — — °I TRANSITION CONTAINMENT SUMP 101 — — — — — — — — — — ° REQUIREMENTS ROUTE t1 <br /> FOR DOUBLE WALL VENT 1 I I OPTIONAL 6" THICK — — — — — — — — — — — ( I TO MONITORING PANEL z <br /> TRANSITION CONTAINMENT SUMP = _ = I CONCRETE SLAB GRADE GRADE PTIONAL 6 THICK — — — — — — - — — — TYPICAL SPILL — — — — — — — — — IN BUILDING <br /> CONCRETE SLAB BUCKET AT — GRADE sEA� <br /> 2" BELLxMALE ADAPTER 4 / ( ( ¢ / I I I I HIGHEST <br /> I III \ �� \ \ �� / - � � � \ III I I\ ELEVATION LEVEL \� .I II II I/ <br /> I I I I I \ / 5 • T� <br /> 3" FRP BONDED FITTING /\\ �- L - - - - — ISI - - \�\\�\\�\\�\\�\\�/ / a — II - - - - - - - - - - III �- — ' \ �\ GRADE I \\� <br /> W/ TEST PORT (TYP.) 38 \T (I / / / / /��� / / / / /�� /�\/ <br /> o . _ IIII <br /> 6" WIDE DETECTA <br /> r <br /> UNDERGROUND MARKING TAPE 11a 1 dc° <br /> \ /OPTIONAL 6 CK-/' leBURIED 6"-12" BELOW FINISHED RACK FOUNDATION TO ° <br /> GRADE: EMPIRE 31-1BE ENCASED IN 2,500 INSTALL (2) 1" TO INSTALL (2) 1 , TO <br /> PSI CONCRETE 1 � <br /> ICONCRETE SLAB II elI a <br /> II <br /> a <br /> MONITORING PAN <br /> EL IN <br /> BUILDING BUILDING <br /> 2" INSIDE 3„ 44 I a 74 2" FLEX CONNECTOR a a aDOUBLE WALL FRP ° 2" FLEX CONNECTOR{TYP.} - - �L- eVENT LINE. SEE \ (TMP ) aNOTE BELOW. LIQUID SENSOR 2" INSIDE 3" DOUBLE WALL NON-DISCRIMINATING FRP VENT LINE SLOPE T0 42 BRINE FILLED DOUBLE 2" INSIDE 3" DOUBLE WALL <br /> -A 4 144"x3" CONCENTRIC 3 ° FRP VENT LINE. SLOPE TO lTANK AT 1/8" PER FOOT 4 BARE STRANDED CU WALL VENT LINE ° <br /> REDUCER (TYP.) <br /> VCA`p <br /> �- <br /> � <br /> IuJ . MINIMUM. SEE NOTE BELOW. 1 2" FLEX CONNECTOR 11Lq 9ROUND WIRE TO TANK TRANSITION SUMP TANK AT 1/8" PER FOOT <br /> BRINE FILLED DOUBLE 111 I I I (TYP.) I I 74 (TYP. I. FIELD GROUND ROD a a MINIMUM. SEE NOTE BELOW. <br /> } <br /> WALL VENT LINE ( I I . al 42" <br /> TRANSITION SUMP <br /> BRINE FILLED DOUBLE <br /> COMPACTED OR NATIVE SOIL WALL VENT LINE <br /> \ II I N(TYPICAL) TRANSITION SUMP \j <br /> SECTON B-B <br /> Y/L DEVELOPMENT INFORMATION:Ia, a' /\\/ <br /> ARCO Nn <br /> a d d a d OPTIONAL 6" THICK <br /> / CONCRETE SLAB am/pm <br /> SECTON �� �� �� � - - - - - - -- - - - - - - - - - - - - - - - - - - FUEL CANOPY <br /> VENT PIPING MOUNTING RACK 12"0 2500 PSI CONCRETE <br /> NOTES: Ia I FOUNDATION / 6 �'P9 <br /> IN ORDER TO PROVIDE MECHANICAL FLEXIBILITY WITHIN THE RIGID FRP PIPING SYSTEM, PROVIDE AT <br /> TON C-C ' ' �, (NEPA 30ALEAST 4 EET OF(2012) §5 31GHT 3(2)),IPE RUN CFC 2010)0RE A§3403.6.9.1)HN E IN DIRECTION OF 30 DEGREES OR MORE. i ® - -�—� — — -- — <br /> SEE DETAIL A <br /> SITE ADDRESS: <br /> THE VENT CONFIGURATION SHOWN IS IN ACCORDANCE WITH CP-201 THE NUMBER OF VENT CAPS AT EXPLOSION PROOF J-BOX I II 0'1 ( f 1 ( 0 1 II I) <br /> 189 ' / � y/ <br /> VAPOR SENSOR ANY GDF SHALL NOT PERMIT AN ADDITIVE LEAK RATE OF MORE THAN .17 CHF AT 2" OF WATER MOUNTED TO POST 11 I — — — — — — — O ESC0H AVELE <br /> OPERABILITY COLUMN. MAX ALLOWED WITHOUT MANIFOLDING IS (3). ( II <br /> LIQUID SENSOR <br /> TEST PORT THE VENT DISCHARGE SHALL BE LOCATED SO THAT VAPORS ARE RELEASED AT A SAFE POINT OUTSIDE NON-DISCRIMINATING 0 II 1 �i'9��6, <br /> INTRINSICALLY SAFE I OF BUILDINGS AND NOT LESS THAN 3.6 M (12 FT) ABOVE THE ADJACENT GROUND LEVEL. VAPORS I II 1 I I II I__+_o <br /> MINI HYDROSTATIC <br /> VALVE ASSEMBLY SHALL BE DISCHARGED UPWARD OR HORIZONTALLY AWAY FROM ADJACENT WALLS. VENT OUTLETS SHALL I 11 II I MONITOR SENSOR IN <br /> GROUP I BE LOCATED SO THAT VAPORS WILL NOT BE TRAPPED BY EAVES OR OTHER OBSTRUCTIONS AND SHALL 2" BELLxMALE ADAPTER4 II 1 (I I HOUSING <br /> 0 TBD <br /> BE AT LEAST 1.5 M (5 FT ) FROM BUILDING OPENINGS. VENTS SHALL BE INSTALLED IN ACCORDANCE (TYP.) I (I II _ II (I 111 BRINE FILLED DOUBLE FACIL <br /> ffY <br /> TEST PORT ACTIVATED WITH (NFPA 30 (2012) §5.7.2), (UFC (2000) §7902.13). (IFC/CFC (2010) §3404.2.7.3.3). II I WALL VENT LINE DESIGNED BY; AwANCE Z&DM: <br /> VALVE CARBON BED D 3" FRP BONDED FITTING3 II L = _ — _ _ _ _ _ _ _ _ = II TRANSITION SUMP AL <br /> VENT RISERS SHOULD STAND NO LESS THAN 3' FROM OUTSIDE EDGE OF CURB W/ TEST PORT (TYP.) �__/ <br /> SERVICEABLE I — — — — — — — —— — - -- �E BY: Ov BP REPS:I <br /> VAPOR SENSOR THE ACTUAL NUMBER OF VENT RISERS IS DETERMINED BY THE NUMBER OF UNDERGROUNDDRAWN BY: AL AWANCE PM: <br /> STORAGE TANKS. THE DIESEL VENT RISER (IF INSTALLED) IS ALWAYS SEPARATE. 4"x3" CONCENTRIC 139 ° ° ° I VON: PROJECT NO: <br /> REDUCER (TYP.) 1 I V-12.0 17223 <br /> 0 0 0 0 <br /> 2" INSIDE 3" DOUBLE 4 12/14/ <br /> SERVICEABLE DESIGN CRITERIA - PER 2007 CBC WALL FRP VENT LINES L — — — — — — — — — — — — — — — — — — — — — — — — DRAWING TITIX: <br /> FILTER ELEMENT4 <br /> (VACUUM MONITORED) NEW VENT STACK <br /> SEISMIC LOADS NOTE: INSTALLATION DETAILS W/ VEEDER=R®0 <br /> SITE INFORMATION IMPORTANCE: 1 SITE CLASS - D I VEEDER ROOT CARBON CANISTER VAPOR CARBON CANISTER VAPOR POLISHER <br /> NOTE: POLISHER TO BE LOCATED IN (CALIFORNIA ONLY) <br /> BASIC RESISTING MAINTAIN A 5 FOOT CLEARANCE TO z I z z CONFORMANCE WITH MANUFACTURERS <br /> SYSTEM: w INSTALLATION MANUAL, LATEST CARB SHEET NO: <br /> R=2 0=2 SD1-1.0 SDS=1.83 GRADE AROUND CARBw ON CANISTER > -1 > w EXECUTIVE ORDER VR-204 AND ALL <br /> (REF: ASCE 7-05 Cd=2.5 - VAPOR POLISHER FOOTPRINT <br /> CANISTER TABLE 15.4-2) APPLICABLE STATE AND LOCAL CODES. <br /> OPERABILITY <br /> TEST PORT (BASE SHEAR EQ. (MAX. BASE SHEAR (MIN. BASE SHEAR <br /> 9 9 DESIGN BASE 12.8-2) EQ. 12.8-2) EQ. 12.8-5&6 c <br /> SECTUN DSHEAR: 0.92W V=CSW V=SDlW/TR/I V=.5S1W/R/I PLAN VIEW G ,20.6.2 <br /> SCALE: NONESCALE: NONE V=0.92W V=1.25W V=0.25W <br />
The URL can be used to link to this page
Your browser does not support the video tag.