Laserfiche WebLink
710F <br /> FVIA OTOCELL F <br /> -- <br /> V f _ -- - -----------____ HOOD EXHAUST FAN <br /> D-6 0.1 KVA,120V1 P2W 3 <br /> 7 I <br /> UTILITY A A ARCO <br /> D-9 A F <br /> ACE <br /> D D D-9 <br /> , X1 <br /> D-1 2 ® h, ® ® h EM f pf D-9 , —9 ¢ A ®®9 z <br /> COOLER ( ) j <br /> F ( ) 'w DIM SWITCHES X D-9 � � o <br /> 17 - ------- PIP EM D-1 <br /> b .... d$® f 4 i N <br /> D-96 <br /> - -- A <br /> _____________________________________________ d D d E D-5 , h <br /> _ D <br /> D-5 7 - Q= D-9 <br /> f <br /> ii — 8 <br /> E E 4 EM d <br /> ® h I I E D-5 O e�\� 5 — c - _ A <br /> D— <br /> c <br /> C 7 D EXHAUST FAN <br /> -1= c A N 0. VA,120V1P2W <br /> B B Bim___ B f <br /> SHEET NOTES ;; Ta <br /> ®®9 ®-1 /� y D®2 D-24— D-2 i � X2 _ _ ----- ---------- <br /> fl� 9 1 ®B� ~'^ SALES AREA 'x '� 11 Ix <br /> i A G HA �.dCNI <br /> 1 POWER FOR ARCO AM/PM SIGN. FIELD VERIFY _ L_——i p24 <br /> LOCATION. ®h r C i <br /> 1 r M <br /> � . LIGHTING IN WALK—IN COOLER/ FREEZER. USE c i. I I ; X � <br /> VAPOR PROOF E FIXTURE ,i I / I — _D_g _ _ os <br /> 3 PROVIDE SEPARATE UNSWITCHED CIRCUIT FOR I i ( I 7 e� <br /> B B � D-8 HLL� A -� ® <br /> EXIT AND EMERGENCY LIGHT FIXTURES. B E E E <br /> �E I D-1 D-1 D-1 D®2 D®2 D®2 I <br /> FIXTURE WITH "EM" SHALL DE PROVIDED WITH " I I I D-8 D 8®D— C® <br /> EMERGENCY BATTERY PACK. PROVIDE I r--®—®®®--®®®—®------ 7---------------------- 7 ( ' e e eEN�i��� <br /> UNSWITCHED CIRCUIT ONLY FOR BATTERY PACK D I I 9c tc ( ( ' 3 D-99 <br /> REFER TO EXHAUST FAN CONTROL DIAGRAM 4 EMh I I ————� — OD-8 j s PHOTOCELL 18215 72ND AVENUE SOUTH <br /> ON DWG. SHEET E5.0. ) ;; I p=5' a KENT, WA 90032 <br /> OCCUPANCY SENSOR & OVERRIDE SWITCH. I I B B B B B D � (425)251-6222 <br /> D-1 --- - L 3 ..____ (6d,w D-2 D-2 D-2 _ D-2 D-2 A A (425)251-8782 FAX <br /> SECURITY CAMERA AND MONITOR WIRING SHALL <br /> BE PROVIDED BYO OWNER'S SECURITY F --- ® i i �_5 9s�"� AM PM SIGN ®_3 91 —® dew 9s 9a� 9 D 4 CIVIL ENGINEERING, LAND PLANNING, <br /> CONTRACTOR. PROVIDE 1/2" CONDUITS TO IRE I �, 0.3KVA020VIP2W -5 d — X D- 4 EW-5 d,w ;! I EM SURVEYING, IIONI'�EV°ffAL CES <br /> HEADEND RECORDER WITH PULL WIRE IF 2 ® � _ , <br /> 13 - _ __� ______ _ Yrs . ._ p�' ®. ®A� c DESCRIPTION <br /> REQUIRED BY LOCAL CODE. SECURITY 71 , d'� 1sa . -- =-- ----- OOD EXHAU FAN <br /> � � SMD-5 7 �. . � ..- < T-- -ti ---. 7 � I <br /> EQUIPMENT LOCATION SHOWN FOR REFERENCEI G G ��--- ----------- --- G - I 0.1KVA,120V1 <br /> ONLY. FINAL LOCATION TO BE DETERMINED BY �' c,w 9 <br /> �- �- PH TOC <br /> SECURITY CONTRACTOR. COORDINATE LOCATION _ AIL I a <br /> OF CAMERAS AND MONITORS WITH SECURITY <br /> CONTRACTOR. H H H H H <br /> JUNCTION BOX FOR WIT LED LIGHT <br /> 4 <br /> PANELS (L3040) CONTROLLED BY LED s <br /> DIMMER SWITCH. EXACT LOCATION TO BE <br /> DETERMINED AT SITE. <br /> 0311 <br /> PHOTOSENSOR TO CONTROL LIGHTS AT <br /> As <br /> DAYLIGHT ZONE <br /> �® <br /> 9 <br /> PRIMARY DAYLIGHT ZONE 10' WINDOW <br /> HEIGHT <br /> 9� SECONDARY DAYLIGHT ZONE 10' WINDOW <br /> HEIGHT SEAU <br /> t <br /> LUM111VAIRE SCHEDULE <br /> CALLOUT SYXBOL LAHP DESCRI PTIICN BA 991$' Sly �A o <br /> WATTS <br /> A (1) 34W LED LED PANEL LIGHT ELECTRONIC CEILING RAB LIGHTING PANEL 34 120V 9P 2W BACKROOM/UTILITY 11 <br /> 2X2-34H ELECTRICAL, OFFICE <br /> RESTROOMS, W/EMERGENCYe ®�� <br /> BATTERY PACK FOR 90 ®� c��.e� 'jgQ <br /> MINUTE ILLUMINATION, <br /> GENERAL UGHT[ING NOTE <br /> 4000K COLOR TEMP <br /> (NEUTRAL) <br /> A. GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF CONFLICTS OCCUR BETWEEN LIGHTING AND ANY OTHER TRADE. DO B (1) 98W LED 12" LED DECORATIVE PENDANT ELECTRONIC CEILING CONTECH LIGHTING TYPE 98 920V 1P 2W SALES AREA 17 <br /> NOT PROCEED WITH INSTALLATION IN THAT AREA UNTIL CONFLICT HAS BEEN RESOLVED TO THE SATISFACTION OF THE ARCHITECT AND CGL1210035KALFC—SCGI2FA <br /> ENGINEER. <br /> C (1) 7.2W LED LLD PENDANT FIXTURE ELECTRONIC PENDANT TECH LIGHTING TYPE 7.2 120V 9P 2W FOOD PREPARATION AREA, 12 <br /> B. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING INSTRUCTIONS FOR ALL LIGHT FIXTURES. ELECTRICAL 700FJCO SLED830 W/ EMERGENCY BATTERY <br /> CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LIGHT FIXTURES AND ASSOCIATED LAMPS INCLUDING ALL NECESSARY PACK FOR 90 MINUTE <br /> HARDWARE AND SUPPORT PER SEISMIC REQUIREMENTS. <br /> ILLUMINATION <br /> D (1) 14W LED REFRIGERATION LIGHTING ELECTRONIC CEILING KASON 1808 LED FIXTURE 14 120V 9P 2W WALK-INC LER/FREEZER, 8 DEVELOPMENT INF AM : <br /> C. ALL WIRES SHALL BE #12 AWG UNLESS NOTED OTHERWISE. W/ EMERGENCY BATTERY <br /> PACK FOR 90 MINUTE ARCO NTI <br /> D. WHERE WIRE SIZES ARE NOTED ON DRAWINGS, THAT SIZE SHALL BE THROUGH THE ENTIRE RUN UNLESS NOTED OTHERWISE. ILLUMINATION, LOW PROFILE <br /> HIGH IMPACT LEXAN GLOBE 3000 arm/pm/ QSR <br /> F. ALL EMERGENCY LIGHT FIXTURES SHALL BE SERVED FROM BATTERY BACKUP. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND WITH ANTI—GLARE FUEL CANOPY <br /> CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. (INSTALL A CENTRAL BATTERY SYSTEM WHERE THE USE TECHNOLOGY, 90-305 VAC, �� ��°� <br /> OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES.). ALL EMERGENCY FIXTURES AND EXIT SIGNS SHALL BE CONNECTED TO 60 HZ, 11808CE0000 <br /> UNSWITCHED HOT LEG OF THE LOCAL LIGHTING CIRCUIT. E (1) 7.2W LED LED DOWNLIGHT FIXTURE ELECTRONIC CEILING RAB LIGHTING TYPE 7.2 120V 1P 2W CASHIER/WASHROOMS, b"W/ 20 <br /> NDLEDAR-50Y-W-S EMERGENCY BATTERY PACK SITE ADD <br /> REft <br /> G. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. FOR 90 MINUTE <br /> ILLUMINATION ESCALON AVENUE <br /> H. REFER TO BUILDING GUIDANCE STANDARDS FOR MATERIAL SELECTION CRITERIA, FINISHES AND GENERAL WORK RULES. F (2) 3.5W LED WALL MOUNTED LED LIGHT ELECTRONIC WALL SLV LIGHTING DELWA NDE, 7 120V 1P 2W SIDE WALLS, SILVERY GREY 6 @ HIGHWAY 120 <br /> COB LED 2X3.5W, 120 VAC ESOALON,CALIFORNIA <br /> I. ELECTRICAL DESIGN BASED ON THE REQUIREMENTS OF 2013 CALIFORNIA GREEN BUILDING STANDARD CODE (CGC) NONRESIDENTIAL 3230794AU <br /> CHECKLIST. THE FOLLOWING STRATEGIES WERE USED: <br /> ALL EXTERIOR LUMINAIRES SHALL BE UNDER 175W AND THEREFORE NOT REQUIRED TO BE CUTOFF TYPE G (1) 9W LED LIGHTING FIXTURE LED, 9W MAX, 120VAC ELECTRONIC CEILING SLV LIGHTING QUADRASYL 9 120V 1P 2W FRONT ENTRANCE 10 — FAC11LI TBD <br /> DESIGN SHALL CONTAIN INTERIOR LIGHTING WITHIN EACH SOURCE E GX53 <br /> DESIGNED LUMINAIRES SHALL BE LEAST 70ft FROM SITE BOUNDARY SO THAT PROVIDED DIRECT BEAM ILLUMINATION THAT LEAVESH (1) 6W LED WALL MOUNTED LED SIGN LIGHT ELECTRONIC WALL SLV LIGHTING MODEL 6 120V 1P 2W FRONT EXTERIOR 6 A b o s s e i n <br /> THE BUILDING SITE IS ZERO. OP ,a <br /> �EASYLIGHT DISPLAY GU9a�' <br /> COMPLETE DESIGN SHALL COMPLY WITH CALIFORNIA ENERGY CODE WITH LED BULB OPTION Engineering, CE <br /> NON CALIFORNIA PROJECTS ARE TO COMPLY WITH THE ENERGY CODE STANDARDS OF THE APPLICABLE JURISDICTION. <br /> 93442U' I I �'�c: <br /> J. GC TO PROVIDE PHOTOMETRIC SURVEY REPORT OF BUILDING INTERIOR AREAS TO CONFIRM THAT AT LEAST 50 FOOT—CANDLE LIGHT X 1 0.7W LED EXIT SIGN W BATTERY BA LITHONIA MODEL M S L L C. 1 3 <br /> { ) / BACKUP ELECTRONIC UNIVERSAL ..Q 0.7 120V 1P 2W SALES, BACKROOM, 3 <br /> INTENSITY IS PROVIDED DURING HOURS OF OPERATION IN THE KITCHEN AND FOOD HANDLING AREAS. OTHER AREAS (INCLUDING WALK—IN 3 R 120/277 EL N OR W/EMERGENCY BATTERY DRAWNG TI <br /> REFRIGERATOR AND FREEZER UNITS) MAY OPERATE WITH A LIGHT INTENSITY OF AT LEAST 10 f$—cd, EXCEPT DURING CLEANING EQUAL PACK FOR 90 MINUTE MECHANICAL — ELECTRICAL <br /> ACTIVITIES WHEN AT LEAST 50 ft—cd INTENSITY MUST BE PROVIDED. ILLUMINATION CIVIL — LEED LIGHTING <br /> K. ALL EMERGENCY LIGHTS SHALL BE PROVIDED WITH UNSWITCHED CIRCUIT IN ADDITION TO THE SWITCH CIRCUIT SHOWN. SWITCHED AND X1 (1) 3W LED EXIT LIGHT LED UNIVERSAL MOUNT ELECTRONIC UNIVERSAL LITHONIA MODELMULE 3 120V 9P 2W BACKROOM, w/EMERGENCY 1 FIRE PROTECTION PLAN <br /> UNSWITCHED CIRCUIT SHALL BE SUPPLIED FROM THE SAME BREAKER. MX—BU BATTERY PACK FOR 90 2100 112TH AVE. NE <br /> MINUTE ILLUMINATION, BELLEVUE, WA 98004 SHEET NO. <br /> SHADED QUADRANT PH: (425) 462-9441 <br /> L. EXPOSED CONDUIT TO LIGHT FIXTURES SHALL BE MINIMIZED BUT WHERE EXPOSED SHALL BE STRAIGHT RUNS JUNCTION TO JUNCTION, DENOTES SIGN FACE, <br /> ORGANIZED AND CONSISTENT IN APPEARANCE. ARROW AS INDICATED, FAX: (425) 462-9451 <br /> WALL OR CEILING MOUNTED E—Mail: cservice@abossein.com <br /> X2 (1) 0.7W LED EXIT SIGN W/ BATTERY BACKUP W/O SIGN ELECTRONIC UNIVERSAL LITHONIA MODEL #LQM S W 0.7 120V 1P 2W WASHROOMS 3 www.abossein.com <br /> 3 R 120/277 EL N OR <br /> EQUAL El m0 <br /> u. .. ..r. . .r ABOSSEIN #216001 <br />