Laserfiche WebLink
- i NOTES:GENERAL <br /> J I I <br /> f I 1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH POWER COMPANY FOR EXACT SERVICE CONNECTION REQUIREMENTS AND, Q INCLUDE ALL NECESSARY COST IN <br /> I fl BID. <br /> r I ` i 2. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH TELEPHONE COMPANY FOR EXACT SERVICE CONNECTION REQUIREMENTS AND INCLUDE ALL NECESSARY COST <br /> UO <br /> IN BID. <br /> ° .............. 3. ALL ELECTRICAL EQUIPMENT SHALL HAVE AIC R <br /> ° Q RATINGS EQUIVALENT OR HIGHER THAN AVAILABLE FAULT CURRENTS PROVIDED BY POWER COMPANY. <br /> t <br /> ���� ARCO <br /> 4. A UTILITY LOCATE SHALL BE PERFORMED PRIOR TO COMMENCEMENT OF TRENCHING. <br /> O <br /> Z ---- Da __ F�--- - c ° -- I I 5. LIGHTING CONTACTOR/TIMER DETAIL IS LOCATED ON SHEET E5.1 <br /> --_ <br /> t <br /> i S 6. REFER TO DRAWING TE2—X FOR FUELING CONDUIT FILL AND WIRE TYPES. <br /> i II r I <br /> _—_ 5 <br /> -- <br /> i._ 1 �� I II it 7. SEE SHEET TE1-1 FOR HAZARDOUS AREA SITE PLAN. <br /> LIGHTINGPOWER & I -- j j i — �' li t t !t t i 8. ALL LIGHTING F <br /> 20'-0° I. ,1� i , (t1l, <br /> NOTES: <br /> IXTURES TO BE FURNISHED AND INSTALLED BY CONTRACTOR. <br /> FLAG <br /> PROVIDE 6 3/4" RGS UNDERGROUND CONDUITS TO FUEL TANKS. <br /> I I (3) 3/4 CONDUITS FOR TURBINE POWER <br /> ISE E E - F-10,12 -- - - (3) 3/4" INTRINSICALLY SAFE CONDUITS FOR TANK MONITORINGHF 9,11 3 _ L DIS NSR <br /> - — I� PROVIDE (3) 1" PVC UNDERGROUND CONDUITS FOR MUSAK AND SECURITY SYSTEMS. STUB IN COLUMN AND EXTEND CONDUITS BACK TO MUSAK AND <br /> 1.92KVA, 08 12 V2 2KVA,2 8/120V2P <br /> c (TY,� I s1 1 S1 S c /11 1 SECURITY SYSTEMS LOCATED PER JACKSONS REPRESENTATIVE. ALL CONDUIT STUB—UPS SHALL BE RGS WITH SEAL OFFS AND MEET THE REQUIREMENTS <br /> O . � 1 O t <br /> I I I SPECIFIED IN ARTICLE 514 OF THE NEC. FIELD VERIFY EXACT LOCATIONS. <br /> Eli _ <br /> I <br /> I °� i (2) 1 ;; CONDUITS FOR MUSAK AND CAMERA WITH PULL ROPE �, v <br /> DIS E� IE F-5,7 F-s,8 E -_ 11 1 I ' I� — (1) 1 CONDUIT FOR MUSAK LOOP TO EACH COLUMN y .� <br /> 0- <br /> F—,--,,FUEL L DISF; it 3 1 <br /> 1.s2KVA, o V2 3W e 2KVA, 8/120Ka + 1 3 PROVIDE (4) 3/4" PVC UNDERGROUND CONDUITS FOR FUEL DISPENSER. ALL CONDUIT TO STUB-UP SHALL BE RGS WITH SEAL OFFS AND MEET THE `�'ey <br /> (;� 1 1 S1 S I 1 G ENG, <br /> I , , i t I REQUIREMENTS SPECIFIED IN ARTICLE 514 OF THE NEC. FIELD VERIFY EXACT LOCATION OF STUB—UPS. <br /> II <br /> ( R E D CD rYR) I l+t I ', — (1) 3/4" CONDUIT FOR POWER <br /> 4 18215 72ND AVENUE SOUTH <br /> I 2 F-2,4 III 1 'I — (1) 3/4„ CONDUIT FOR DATA KENT, WA 98032 <br /> 3 FUEL DISE . E F-1'3 !�L DIS E�SER 4 — (2) 3/4 CONDUIT SPARE <br /> 1.92KVA, V2 3W 2KVA, /120V� J I ` (425)251-6222 <br /> (425)251-8782 FAX <br /> .12 D1 1 t I 1 4 PROVIDE (2) 3/4" PVC UNDERGROUND CONDUITS FOR CANOPY LIGHTING AND SIGNS. ALL CONDUIT TO STUB—UP SHALL BE RGS WITH SEAL OFFS AND <br /> I� 1 CIVIL ENGINEERING, LAND PLANNING, <br /> MEET THE REQUIREMENTS SPECIFIED IN ARTICLE 514 OF THE NEC. FIELD VERIFY EXACT LOCATIONS. EXTEND CONDUIT BACK TO LIGHTING CONTACTOR AND SURVEYING, ENVIRONMENTAL SERVICES <br /> ASTRONOMIC TIME CLOCK. SEE SHEET ENLARGED CANOPY PLAN E4.1 FOR CIRCUIT IDENTIFICATION. <br /> -- -- — _ O I ? I NO. DATE F"SION DESMIPnON <br /> s i I D-15 <br /> S2 -- — 1#8 �B y j E PROVIDE NEW LIGHT FIXTURE. INSTALL 3/4" PVC UNDERGROUND CONDUIT CONTAINING: (2) #10 THWN CU. AND (1) #10 CU EGC. FOR PARKING LOT <br /> F-1 <br /> 1.18.15 PERMrr SUBMrrrAL <br /> 3,15F-14,16 0 I t 5 <br /> 5- <br /> —^ -- o t1 ' I LIGHTING. EXTEND CONDUIT BACK TO ASTRONOMIC TIME CLOCK. <br /> —. <br /> PROVIDE AND INSTALL ESO SWITCH AND WEATHERPROOF GFI RECEPTACLE AT OVERFILL ALARM STATION. INCLUDE ALL ASSOCIATED CONDUIT AND WIRE FOR <br /> JCOMPLETE INSTALLATION PER NEC 514.11 AND NFPA 30A SECTION 6.7. RUN WIRE IN 1 PVC SCH. 40 CONDUIT AND STUB UP WITH RGS. SEE DETAIL 3 <br /> (TYP A B C (TYP) A B C 'I + , 1/E2.0. COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. SEE DETAIL 1/TE1.1 FOR ELEVATION. <br /> BMERSIBLE TURBINE PUMP SUBMERSIBLE RBINE PUMP !! <br /> 2.74KVA,208/120V2P3W 2.74KVA,2 /120V2P W --7+ ;' I I PROVIDE AND INSTALL ESO SWITCH. COORDINATE EXACT LOCATIONS WITH OWNER PRIOR TO INSTALLATION. SEE STORE FLOOR PLAN ON SHEET E3.0 FOR a3 <br /> AM WATER UNII + I t f I I ENLARGED PLAN OF ESO LOCATIONS. (TYPICAL) <br /> { 1 7 <br /> 8 1. P,12C V1 P2 I I I I ! 1 ' l 1 1 <br /> i PROVIDE 3/4" PVC UNDERGROUND CONDUIT AND 3 12 THHN CU. WIRE FOR NEW AIR STATION. MAKE CONNECTION WITH WATER TIGHT FLEX BOXES AND <br /> __(--_— COVERS AS REQUIRED BY MANUFACTURER. FIELD VERIFY EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. <br /> s –32 A 'n _OQ LSA-G_ <br /> 0 <br /> 1/ C,1#8C#8N,#8G i ; I 1 � PROVIDE (1) 3" PVC CONDUIT WITH 1/4" PULL STRING FOR TELEPHONE. FIELD VERIFY EXACT VAULT LOCATION WITH SERVICE PROVIDER PRIOR TO <br /> oT ,'�11 tit INSTALLATION. <br /> I <br /> EB 84U S26 B :30 ARC T SIGN <br /> 5 �� , 1.9KV 1 V P ; to of ° <br /> ; f� <br /> EI1�7915 <br /> zR11 <br /> MINING KING .......... <br /> �(�ls <br /> Iof �.1* 8CES. EL P 800A, 120/208V 3PH . <br /> + <br /> R MAIN SECTION 1 1 ®®® <br /> -- —`--` —= — � tt ; A TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK- FILL OPENING) D TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE- PITS) <br /> SWITC 0 I O EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> 14=721 LI-j-O 10 20 40 � � � {� w � � I EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> XFMR o tt 1' Any pit, box, or space below grade level, any part of which is within the Division 1 Any pit, box, or space below grade level, any part of which is within the <br /> �� t I f 1' J or 2 classified location. <br /> Division 1 or 2 classified location. <br /> SE RFT1o ° _ I EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br /> (3) kC I, 300k G I Up to 18 inches above grade level within a horizontal radius of 10 feet from a loose TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE DISPENSER) <br /> UTI TRAN MER F� t � , E <br /> ° t fill connection and within a horizontal radius of 5 feet from a tight fill connection. EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> 300KVA 2.1% IMP. g EB � t g Space classification inside the dispenser <br /> enser enclosure is covered in ANSI/UL 87,SCHEDULE: TO BE VERIFIED p p <br /> U TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK VENT DISCHARGING UPWARD) "Power Operated Dispensing Devices for Petroleum Products." <br /> SEE ERAL NOTES O EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: <br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION DISPENSING DEVICE - DISPENSER <br /> S1 LSI PASO ° _____ L 3 YB Within 3 feet of open end of vent, extending in all directions. ( ) <br /> - CATALOG #PASO-S-LED-HO-CW-UE-WHT; SINGLE FIXTURE; WHITE FINISH ED. F EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: DEVEI-aPMENT INFORMATIOW <br /> Space between 3 feet and 5 feet of open end of vent, extending in all directions. Within 18 inches horizontally in all directions extending to grade from (1) the ARCO TI <br /> dispenser enclosure or (2) that portion of the dispenser enclosure containing <br /> s2 LSI GREENLEE LED SPEC GRADE BOLLARD XHYP3 WITH DOME TOP 360° LIGHTING WHI FINISH °E� ° c ( ) liquid handling com p p 300 am/ m/ <br /> ( ) TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION REMOTE PUMP - OUTDOOR q g ponents. Space classification inside the dispenser enclosure OSR <br /> CATALOG # XHYP3-360—LED-30-350—CW—UE—WHT—DT; INCLUDING ANCHOR BOLTS ---- O EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: is covered in ANSI/UL 87, Power Operated Dispensing Devices for Petroleum FUEL CANOPY <br /> — FULL OUTPUT POWER: 34W, 1690 LUMENS. (50 LUMENS/WATT) Any pit, box, or space below grade level if any part is within a horizontal distance Products." / 's <br /> of 10 feet from any edge of pump. <br /> EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - OUTDOOR) <br /> ENCLOSURE/DEVICE Within 3 feet of any edge of pump, extending in all directions. Also up to 18 inches O EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: <br /> ADDPZM- <br /> above grade level within 10 feet horizontally from any edge of pump. Up to 18 inches above grade level within 20 feet horizontally of any edge SITE <br /> of enclosure. <br /> 18" ESCALON AVENUE <br /> MAXIMUM @ HIGHWAY 120 <br /> RGS VEHICLE ACCESS SIDE TRENCH WIDTH ESCALON,CALIFORNIA LED LUMINAIRE 24" MIN <br /> CONDUIT SEAL–OFF FINAL GRADE FACILITY # TBD <br /> 7_ 11 ET 7771-r t 1 'EiF ( i . —• <br /> RGS CONDUIT STUB–UP YELLOW WARNING RIBBON tv!: ,-r _11 A b 0 S S e I nom6r BP : <br /> DRAVIN BY. AWANCE PM <br /> BACK FILL MATERIAL <br /> OV R <br /> (li ': 4" MIN Engineering, : <br /> 4 SQUARE STEEL POLE – 14' HIGH, WHITE FINISH i CONCRETE r i ii Y i 48" v PROJECT� <br /> CATALOG # 4SQBO–SO7G-14–S–WHT i 1 <br /> MAX L. L. C. <br /> ACCESSORIES: 4BC #122559CLR <br /> 3 <br /> " CLEAN BACKFILL f ,' , <br /> ER2 #122566CLR [RAINING � ` <br /> 24" =�1 =l.t-. NOTE: MECHANICAL - ELECTRICAL `�I <br /> �II_-_;:_r--, - ;=� ,=_ _– .---•;�� ® SEE POWER COMPANY CIVIL – LEED POWER LI <br /> NOTE: MINIMUM -iI( L iii;. 1I!; E'_i.:;.ill_ =_I'i:_ ; _ <br /> ..,i�;�._ <br /> GHTING <br /> ALL EXTERIOR LIGHT FIXTURES TO BE SECONDARY SCH. 40 SERVICE HANDBOOK FORADDITIONAL REQUIREMENTS FIRE PROTECTION <br /> SITE PLAN <br /> COMBI ATION.BY TIMESWITCH/CONTACTOR SCH. 40 PVC CONDUIT WITH ® ALL UNDERGROUND 2100 112TH AVE. NE <br /> PVC CONDUIT 2" SEPARATION. CONDUIT SHALL COMPLY <br /> ------�_ WITH NEC 300-5. BELLEVUE, WA 98004 SHEET NO. <br /> FOR LOCATIONS, SEE SITE PLAN: SCH. 40 PVC TO RGS FITTING PH: 425 462-9441 <br /> PARKING LOT LIGHT ( ) <br /> FAX: (425) 462-9451 <br /> 2I L E-Mail: cservice@abosseia.com <br /> SITE LIGHT DETAIL TYPICAL - I www.abossein.com <br /> SCALE: NOT TO SCALE �E2. O NTS 2.O NTS <br /> E2mO <br /> ABOSSEIN #216001 <br />