DEMO STOREFRONTGLASS WINDOW/ DOOR0.50.50.200.210.210.90.90.210.220.210.200.200.200.200.200.230.230.200.200.16DOOR DESIGNATION - SEE DOOR SCHEDULE ON SHEET A5SYMBOL LEGENDSTOREFRONT DESIGNATION - SEE SCHEDULE ON SHEET A5MATERIAL FINISH DESIGNATION, SEE SHEET A2KEYNOTE DESIGNATIONROOM NAME DESIGNATION?101?Room name101A2PRIOR TO BID, CONTRACTOR SHALL VISIT THE SITE TO ADEQUATELY DETERMINE ALLPRE-EXISTING CONDITIONS AND THE FULL EXTENT OF ALL REQUIRED DEMOLITION. BY THEACT OF SUBMITTING A BID, THE CONTRACTOR WILL BE DEEMED TO HAVE COMPLIED WITHTHE FOREGOING, TO HAVE ACCEPTED SUCH CONDITIONS, AND TO HAVE MADEALLOWANCES THEREFORE IN PREPARING HIS BID.1.EXISTING PARTITIONS NOT SHOWN SHALL BE REMOVED. VERIFY THAT ALL PARTITIONSTO BE REMOVED ARE NON-LOAD BEARING PRIOR TO REMOVAL. NOTIFY ARCHITECTOF ANY LOAD BEARING WALLS INDICATED TO BE REMOVED.2.REMOVE EXISTING FLOOR FINISHES, UNLESS SHOWN TO REMAIN, AND PREPARE FLOORTO RECEIVE NEW FINISHES AS SCHEDULED. LEVEL UNEVEN AREAS OF FLOOR ASREQUIRED.3.REMOVE EXISTING WALL FINISHES AND PREPARE WALL SUBSTRATES TO RECEIVE NEWWALL FINISHES AS SHOWN AND SCHEDULED. FURR WALLS WITH SUPPLEMENTAL FRAMINGMEMBERS WHERE SHOWN AND WHERE REQUIRED FOR INSTALLATION OF SERVICES,INSULATION AND FINISHES.4.VERIFY PROPOSED SUSPENDED CEILING HEIGHT WITH EXISTING STRUCTURE, STOREFRONTHEIGHT AND NEW HVAC AND ELECTRICAL WORK. COORDINATE ALL CONDITIONS WITHARCHITECT.5.CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AS REQUIRED TO MAINTAINSTRUCTURAL STABILITY OF THE EXISTING STRUCTURE DURING ALL PHASES OFCONSTRUCTION.6.CONTRACTOR TO COORDINATE REMOVAL AND STORAGE OF ALL EQUIPMENT ANDFIXTURES WITH OWNER.7.WHERE ANY PLUMBING, MECHANICAL, OR ELECTRICAL ITEMS, LINES, CONDUITS, PIPES,FIXTURES, ETC., HAVE BEEN REMOVED; PLUG AND CAP PIPES, CONDUITS, LINES, ETC.BELOW FLOOR, BEHIND FACE OF WALL OR ABOVE CEILING AS NECESSARY TO CONCEALABANDONED ITEMS. PATCH AND REPAIR FLOOR, CEILING AND/OR WALLS AS NECESSARY.8.CONTRACTOR TO PATCH AND REPAIR ANY DAMAGED PORTIONS OF THE BUILDING TOREMAIN AND MATCH NEW OR EXISTING WORK.9.ALL INTERIOR WALLS ARE TO BE BELIEVE NON-LOAD BEARING AND NON-LATERALRESISTING. NO STRUCTURAL WALLS ARE TO BE REMOVED (U.O.N.). CONTRACTOR TOFIELD VERIFY STRUCTURAL CONDITIONS.10.THIS PLAN INDICATES A GENERAL DEMOLITION SCOPE OF WORK TO BE PREFORMED ANDDOES NOT RELIEVE THE CONTRACTOR FROM OTHER INCIDENTAL DEMOLITION WORKREQUIRED TO COMPLETE THE BUILDING MODIFICATIONS AS SHOWN AND REQUIRED BY THECONTRACT DOCUMENTS INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL ANDHVAC.11.ANY ITEMS SALVAGED BY THE CONTRACTOR SHALL BE DISPOSED OFPROPERLY OFF-SITE AND IN AN EXPEDITIOUS MANNER.12.PROTECT ALL PEDESTRIAN TRAFFIC AFFECTED BY THE DEMOLITION ANDCONSTRUCTION WORK, AS SET FORTH IN THE BUILDING CODE. HEIGHT ANDBARRICADE CONSTRUCTION, IF ANY, TO BE DETERMINED BY LOCAL PUBLICAGENCY.13.PROTECT FROM DAMAGE DURING CONSTRUCTION ALL EXISTING WALLS,FLOORS, CEILINGS, ETC., THAT ARE TO REMAIN.14.IF CONTRACTOR ENCOUNTERS ANY HAZARDOUS MATERIALS DURING DEMOLITION ORCONSTRUCTION, HE SHALL IMMEDIATELY SUSPEND WORK AND NOTIFY THE BUILDINGDEPARTMENT BEFORE PROCEEDING.15.NO STRUCTURAL WALL OR COLUMN SHALL BE DEMOLISHED, UNLESSOTHERWISE NOTED.16.CLEAN EXISTING DOORS AND WINDOWS.DEMOLITION NOTES17.DIMENSIONS ARE FOR INFORMATION ONLY. CONTRACTOR TO FIELD VERIFYEXISTING DIMENSIONS WHERE NECESSARY.18.50% OF NON-HAZARDOUS DEMOLITION MATERIALS SHALL BE RECYCLED.2018 SCHUSS CLARK BRANDONARCHITECTS, INCORPORATEDcSCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, EXPRESSLY RESERVE THEIR COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT OBTAINING WRITTEN PERMISSION AND CONSENT OF SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED SHOULD UNAUTHORIZED RE-USE BY A THIRD PARTY OCCUR, SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, SHALL BE HELD HARMLESS.biddingplan chkpermitafterDocument StatusSheet Contentissuepermitrecheckfirstplan checkissued toRevisionsSheet NumberProject:Checked by:Drawn by:Date:rechecksecondPRINTED:110408 TRINITY PKWY, STOCKTON, CA 952199/25/2018 1:31:10 PMA0.009/26/18EGJB18-442.18CONST DOCSDEMOLITIONFLOOR PLANSCALE: 3/16" = 1'-0"1Floor Plan - DemoDEMOLITION KEYNOTESNO. DESCRIPTION0.5 EXISTING STOREFRONT DOOR TO BE REMOVED.0.9 EXISTING DOOR TO BE REMOVED.0.15 VERIFY EXISTING ELECTRICAL PANELS.BRACE EXISTING PANEL0.16 EXISTING NON-STRUCTURAL WALL TO BE REMOVED. VERIFY EXISTING CONDITIONS INFIELD.0.20 EXISTING WALL TO REMAIN.0.21 DEMOLITION OF EXISTING WALL.0.22 EXISTING ROOF LADDER.0.23 EXISTING COLUMNS.05-16-18