My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10408
>
1600 - Food Program
>
PR0543979
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2023 10:44:09 AM
Creation date
1/12/2023 10:39:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0543979
PE
1617
FACILITY_ID
FA0025016
FACILITY_NAME
SEE'S CANDIES
STREET_NUMBER
10408
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
CURRENT_STATUS
01
SITE_LOCATION
10408 TRINITY PKWY STE B
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.PROVIDE FIRE BLOCKING AT 10'-0" HORIZONTAL AND VERTICAL INTERVALS AT COMBUSTIBLECONSTRUCTION PER CBC 2016.DIMENSIONS ARE TAKEN FROM CENTERLINE OF GRIDLINE, FACE OF WALL FINISH, UNLESS OTHERWISENOTED.2.FIRE DEPT. FINAL INSPECTION REQUIRED. SCHEDULE INSPECTION 72 HOURS IN ADVANCE.3.LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHER TO BE DETERMINED BY FIRE INSPECTOR. MIN. SIZE2A10BC AT 75 FEET TRAVEL DISTANCE.4.EXIT DOORS AND EXIT GATES SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANYSPECIAL KNOWLEDGE OR EFFORT.5.DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOFSHALL BE PROVIDED. EXITS,EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS AND FIRE EXTINGUISHERLOCATIONS SHALL NOT BE CONCEALED BY DECORATIVE MATERIAL.6.ALL FLOOR TRANSITIONS TO BE FLUSHED, 1/2" MAXIMUM HIGH THRESHOLD AT ALL DOORS.7.8.PROVIDE KNOX BOX (FIRE DEPT. KEY BOX) AT THE ENTRANCE THREE (3) COMPLETE SETS OF KEYS MUSTBE PROVIDED. KEYS MUST BE PROVIDED FOR ALL ROOMS CONTAINING FIRE AND LIFE SAFETYSYSTEMS CONTROLS.SEE CITY FIRE DEPT. KNOX BOX REQMNTS (FIELD VERIFY EXISTING CONDITIONS).9.VERIFY THAT ALL ROOF AREAS HAVE POSITIVE DRAINAGE (MIN. 1/4" PER FOOT) PRIOR TO APPLYINGANY ROOFING MATERIALS.10.GENERAL NOTESPROVIDE TACTILE EXIT SIGNS PER 7/G2 AT ALL GROUND LEVEL EXIT DOORS.NOT A PART6018ADJACENT B/MOCCUPANCYLEASE LINELEASE LINE481.21.21.91.131.161.121.11EXITEXITBC234A5SALES AREA100OFFICE106OFFICE107MENS103WOMENS104HALL105WORK ROOM102UTILITY109VESTIBULE108EXITLEASE LINE6048LEASE LINE2' - 0"3' - 0"1' - 1 1/2"12' - 0"1' - 1 1/2"40' - 0"44' - 2"14' - 6"8' - 4"1' - 7"3' - 4"12' - 3"2' - 7"16' - 6"5"26' - 3"14' - 4"3' - 7"64' - 11"(E) 99'-5"5"5"2' - 7"8' - 5 1/2"8' - 5 1/2"5' - 1"5"11' - 8"32A1.32589748"48"4A4B1A1B6A6BMDLMDLFMDL1.71.21.71.41.31.181.151.171.241.182.121.161.251.252.121012' - 7"99' - 7" (E) 63'-11" 44'-3"9' - 4"5"9' - 4"8' - 7"5"2' - 0"WALL LEGEND4" PARTITIONSTUD WALLEXISTINGDEMISINGWALL3 5/8" OR 6" X 20 GA STEEL STUDS, PER ICC#ER-3403P, AT 16" O.C. WITH (1) LAYER 5/8"TYPE "X" GYP. BD. EA SIDE; TAPED, SPACKLED,SANDED & PAINTED.PARTITION HGT. AT LAY-IN CLG'S TO 6" ABOVEHIGHEST CEILING LEVEL; AT GYP. BRD. CLGS.STUDS SHALL EXTEND TO JOIST EVERY 4'-0"(SEE DET.)NOTE AT TOILET WET AREAS PROVIDEMOISTURE RESISTANT (GREEN BRD.) GYP. BRD.,G.C. TO PROVIDE 16 GA. METAL STUDS ATWATER HEATER WALLS TO BE LATERALLYBRACED WITH 3 5/8" METAL STUDS AT 48"O.C.INSTALL BATT INSULATION AT RESTROOMWALLSG.C. TO EXTEND GY. BRD. TO CEILING ANDINSULATE IF NOT EXISTINGPLUMBINGWALL3 5/8" X 20 GA STEEL STUDS, PER ICC #ER-3403P, AT 16" O.C. WITH (1) LAYER 5/8"GREEN BOARD) GYP. BD.; TAPED, SPACKLED,SANDED & PAINTED.6" PARTITIONSTUD WALL1 5/8" X 20 GA STEEL FURRING STUDS, PER ICC#ER-3403P, AT 16" O.C. WITH (1) LAYER 5/8"GYP. BD.; TAPED, SPACKLED, SANDED &PAINTED. (WINDOW GRAPHICS VERIFY EXACTLOCATION W/ CONSTRUCTION MANAGER)FURREDWALLDOOR DESIGNATION - SEE DOOR SCHEDULEON SHEET A5SYMBOL LEGENDSTOREFRONT DESIGNATION - SEE SCHEDULEON SHEET A5MATERIAL FINISH DESIGNATION, SEE SHEET A2KEYNOTE DESIGNATIONROOM NAME DESIGNATION?101?Room name101A22018 SCHUSS CLARK BRANDONARCHITECTS, INCORPORATEDcSCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, EXPRESSLY RESERVE THEIR COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT OBTAINING WRITTEN PERMISSION AND CONSENT OF SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED SHOULD UNAUTHORIZED RE-USE BY A THIRD PARTY OCCUR, SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, SHALL BE HELD HARMLESS.biddingplan chkpermitafterDocument StatusSheet Contentissuepermitrecheckfirstplan checkissued toRevisionsSheet NumberProject:Checked by:Drawn by:Date:rechecksecondPRINTED:110408 TRINITY PKWY, STOCKTON, CA 952199/26/2018 12:36:47 PMA1.109/26/18EGJB18-442.18CONST DOCSFLOOR PLANFLOOR PLAN KEYNOTESNO. DESCRIPTION1.2 LINE REPRESENTS EDGE OF CABINETRY.1.3 (N) MOP SINK, REFER TO PLUMBING PLANS, SEE DETAIL ON SHEET A8.1.1.4 (N) 3 COMPARTMENT SINK STAINLESS STEEL SINK, SEE PLUMBING PLANS.1.5 (N) WATER HEATER ON RAISED PLATFORM ABOVE MOP SINK. REFER TO DETAIL SHOWN ONSHEET A5, SEE PLUMBING PLANS.1.7 (N) HAND SINK, SEE PLUMBING PLANS.1.9 (E) PAIR 3'-0" X 7'-0" WHITE ALUMINUM DOORS AND FRAME WITH TRANSOM AND SIDE LITE.PROVIDE NEW LATTICE - SEE DETAILS 4/A7 & 5/A7. U VALUE = MAX .41 / SHGC = .261.11 TACTILE "EXIT" SIGNS AT MAIN EXITS PER CBC SEC. 1117B.5.11.12 (N) LATTICE - SEE DETAILS 4/A7 & 5/A7. U VALUE = MAX. .41 / SHGC = .261.13 (E) ALUMINUM STOREFRONT FRAMING AND GLAZING.1.15 (N) 2A10BC RECESSED FIRE EXTINGUISHERS1.16 (E) STOREFRONT FACADE TO REMAIN.1.17 G.C. IS TO INFILL / REPAIR CONCRETE FLOOR AS REQUIRED FOR NEW UNDERGROUNDPLUMBIG. REFER TO PLUMBING PLANS. COORDINATE WITH LANDLORD FOR ALLREQUIREMENTS PRIOR TO START OF WORK. G.C. TO INSTALL VAPOR BARRIER AT ALLDEMO'D FLOORING AREA. NEW CONCRETE TO BE DOWELED IN TO EXISTING WITH #4 REBAR AT18" O.C. W/ 4" EPOXYED EMBED.1.18 (N) RESTROOM FIXTURES AND ACCESSORIES. VERIFY ALL FIXTURES COMPLY WITHACCESSIBILITY REQUIREMENTS, REFER TO SHEET CS2.1.24 (E) ROOF LADDER. 011.25 (E) COLUMNS.SCALE: 3/16" = 1'-0"1PROP0SED FLOOR PLAN05-16-18
The URL can be used to link to this page
Your browser does not support the video tag.