Laserfiche WebLink
COORDINATE FINAL SOFFITLIGHTING LOCATIONS WITHSEE'S CONSTRUCTION MANAGERNOTE: RESTROOMEXHAUST FAN MUST BEINTERCONNECTEDWITH LIGHT SWITCH.2.12BC234A5HOLD6' - 8"HOLD1' - 0"A.F.F.GWB - C38' - 0"A.F.F.GWB - C38' - 0"A.F.F.2' x 4' - C212' - 0"A.F.F.2' x 2' - C110' - 0"A.F.F.2' x 2' - C19' - 0"A.F.F.2' x 2' - C19' - 0"A.F.F.Diffuser Eggcrate7' - 6"21' - 0"2.122.1223 7/8"24"24"24"24"24"24"24"24"24"24"24"24"24"HOLD2' - 0"2.102.82.112.92.62.52.72.32.32.6A8.0149A8.013A8.012A8.0A.F.F.2' x 2' - C110' - 0"30"24"24"24"24"30"TYP. SUSPENDED CEILING DETAILS1A8.02A8.03A8.04A8.05A8.06A8.07A8.08A8.02.3DOOR DESIGNATION - SEE DOOR SCHEDULE ON SHEET A5SYMBOL LEGENDSTOREFRONT DESIGNATION - SEE SCHEDULE ON SHEET A5MATERIAL FINISH DESIGNATION, SEE SHEET A2KEYNOTE DESIGNATIONROOM NAME DESIGNATION?101?Room name101A22X4 LED T-BAR DROP IN FIXTUREWITH 90 MIN. EMERGENCY BALLAST NIGHT LIGHTSEE ELECTRICAL DRAWINGSRECESSED DOWNLIGHT FIXTURESEE ELECTRICAL DRAWINGS1X4 LED FIXTURESEE ELECTRICAL DRAWINGS2'-0' LED WALL WAHER LIGHT FIXTURESEE ELECTRICAL DRAWINGSLIGHTING LEGEND2X4 LED T-BAR DROP IN FIXTURESEE ELECTRICAL DRAWINGSEMERGENCY EXIT SIGNSEE ELECTRICAL DRAWINGSMECHANICAL RETURN AND SUPPLY DIFFUSERSEE MECHANICAL DRAWINGS2X4 LEDT-BAR DROP IN FIXTUREWITH EMERGENCY NIGHT LIGHTSEE ELECTRICAL DRAWINGS2X2 LED T-BAR DROP INFIXTURESEE ELECTRICAL DRAWINGS2018 SCHUSS CLARK BRANDONARCHITECTS, INCORPORATEDcSCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, EXPRESSLY RESERVE THEIR COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT OBTAINING WRITTEN PERMISSION AND CONSENT OF SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED SHOULD UNAUTHORIZED RE-USE BY A THIRD PARTY OCCUR, SCHUSS CLARK BRANDON ARCHITECTS, INCORPORATED, SHALL BE HELD HARMLESS.biddingplan chkpermitafterDocument StatusSheet Contentissuepermitrecheckfirstplan checkissued toRevisionsSheet NumberProject:Checked by:Drawn by:Date:rechecksecondPRINTED:1210408 TRINITY PKWY, STOCKTON, CA 952199/26/2018 9:54:17 AMA1.209/26/18AuthorChecker18-442.18CONST DOCSREFLECTEDCEILING PLANSCALE: 3/16" = 1'-0"1REFLECTED CEILING PLANCEILING KEYNOTESNO. DESCRIPTION2.3 NEW LIGHT FIXTURES.COORDINATE WITH ELECTRICAL PLANS.2.5 ILLUMINATED VALANCE WITH POLISHED CHROME EGG CRATE DIFFUSER. 3/4" PLYWOOD FASCIAWITH WHITE PLASTIC LAMINATE FINISH AT ALL EXPOSED WOOD EDGES. SEE DETAIL SHEET A5.2.6 NEW T-BAR CEILING AND GRID PER SPECIFICATIONS2.7 NEW RECESSED CAN LIGHT FIXTURES PER ELECTRICAL DRAWINGS2.8 EMERGENCY LIGHT FIXTURE. SEE ELECTRICAL PLANS2.9 LIGHT FIXTURES SHOWN ON REFLECTED CELING PLAN ARE SHOWN FOR LOCATION ANDCOORDINATION ONLY.SEE ELECTRICAL DRAWINGS FOR COMPLETE LIGHT FIXTURE SCHEDULE.2.10 SUSPENDED CEILING SHALL COMPLY WITH CBC 2013.2.11 FOR DIFFUSERS AND EXHASUT FANS, SEE MECHANICAL DRAWINGS.2.12 EXIT SIGN. SEE ELECTRICAL PLAN