COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 2:44:35 PM
Creation date
1/13/2023 9:39:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0518288
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3250 W GRANT LINE RD TRACY 95377
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f5 PEIIRP1200-12 <br />there are items that must be repaired or replaced <br />(e.g., deteriorated penetration fitting boots), <br />notify the owner/operator and obtain approval <br />prior to proceeding with repairs. <br />4. Test boots or secondary containment termina- <br />tion fittings must be present on the piping pen- <br />etrating the sump. During testing, these fittings <br />prevent water from entering the interstitial space <br />of double -walled piping. Without these fittings, <br />the integrity of the sump cannot be tested using <br />this method. <br />5. If interstitial monitoring sensors are present <br />within the containment sumps, temporarily <br />remove them before conducting the test. If the <br />sensor is removed, reposition after testing to <br />appropriate position according to the manufac- <br />turer's instructions. <br />6. If the containment sump is found to have cracks, <br />loose parts or separation of any joints or penetra- <br />tion fittings, it is not considered to be liquid - <br />tight. This visually indicates a test failure. <br />CAUTION: Water can damage electrical <br />connections. Ensure that there are no <br />components that can be damaged by the <br />addition of water to the sump. If such <br />components are present, take appropriate <br />precautions when performing the test or <br />use an alternative test method. <br />�l <br />Water Electrical <br />- Level <br />Junction <br />_ Box <br />Electrical <br />Conduit <br />Product <br />Piping <br />P <br />FIGURE 6-5. The test fluid level in the UDC most be at <br />least 4 inches above the highest sump penetration or <br />sidewall seam. <br />0 pei.org <br />6.5.6 Test Procedure. <br />1.. Begin the test by adding water to the sump to a <br />minitnum of 4 inches above the highest sump <br />penetration or sump sidewall seam, whichever is <br />higher. To compensate for sump deflection, the <br />water must be allowed to settle a minimum of <br />15 minutes before taking the initial test measure- <br />ment. If the highest sump penetration or sump <br />sidewall seam is less than 4 inches from the top <br />of the sump, add water to within 1 inch of the <br />top of the sump. <br />2. Place the measuring stick vertically at the lowest <br />point in the sump and extending above the water <br />level in the sump to allow for an accurate mea- <br />surement to be taken. The location of the mea- <br />suring stick must remain the same for each water <br />level measurement. Document the initial water <br />level measurement as measured from the bottom <br />of the sump. Alternative measurement methods <br />may be used provided that the measurement to <br />1116 (0.063) inch can be made. <br />3. Take all precautions to prevent the water level <br />from being disturbed during the duration of the <br />test. <br />4. After 1 hour, document the ending water level <br />:measurement. <br />5. Upon completion of the test: <br />• remove all water and properly dispose of it <br />according to Section 6.7; <br />• reinstall any interstitial monitoring sensors in <br />their proper positions; <br />• return the test boots or secondary contain- <br />ment fittings to their pre-test operating con- <br />figurations; <br />FIGURE 6-6. To prevent leakage, check all penetration <br />fittings before adding water to ensure they make a tight <br />seal. <br />