My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 2:44:35 PM
Creation date
1/13/2023 9:39:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0518288
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3250 W GRANT LINE RD TRACY 95377
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities <br />2. Clean the spill bucket and examine it for dam- <br />age. Make sure that it is free of cracks, loose <br />parts or separation of the bucket from the fill <br />pipe. If the spill bucket is damaged notify the <br />owner/operator. <br />3. Attach the test apparatus to the test port. <br />4. Connect the line from the vacuum source to the <br />test apparatus. <br />5. If the spill bucket is found to have cracks, loose <br />parts or separation of the bucket from the fill <br />pipe, it is not considered to be liquid -tight. This <br />visually indicates a test failure. <br />6.4.5 Test Procedure. <br />1. Slowly apply a vacuum of 15 inches water <br />column to the spill -bucket interstitial space and <br />close the control valve. If a 15 -inch water col- <br />umn vacuum cannot be attained, the spill bucket <br />fails the test. See Appendix B for pressure and <br />vacuum conversions. <br />2. Start the time -measurement device and record <br />the initial vacuum level shown on the gauge. <br />3. After 1 minute, record the ending vacuum level. <br />Upon completion of the test, release the vacuum, <br />remove the test apparatus and restore the spill <br />bucket to its normal operating condition. <br />6.4.6 Pass/Fall Criteria. If the ending vacuum <br />level is 12 inches water column or greater, the spill <br />bucket passes the test. <br />If the ending vacuum level is less than 12 inches <br />water column, the spill bucket fails the test. <br />6.5 Containment Sump Integrity Testing. <br />CAUTION: Gaining access to the contain- <br />ment sump requires removing the lid, <br />cover or dispenser panel that is in place to <br />protect the equipment in the sump. These <br />components can be heavy. They may <br />require special handling and more than <br />one person to remove them. Use caution <br />when moving and replacing them when <br />testing is complete. During the test, put <br />the covers and panels in a safe location <br />where they are secure and isolated from <br />vehicle and customer traffic. <br />6.5.1 General. Containment sumps are liquid - <br />tight structures designed to temporarily contain <br />leaks or spills. In addition, containment sumps <br />often serve as the leak detection monitoring loca- <br />tion for double -walled piping systems. Leakage <br />from the primary containment typically flows by <br />gravity inside the secondary containment to the <br />sump, where it can be easily observed or detected <br />by a sensor. <br />This section describes a hydrostatic test method. <br />There are vacuum test methods available for con- <br />tainment sumps. Consult the manufacturer before <br />performing a vacuum test. <br />NOTE: Follow the manufacturer's instructions <br />when testing the interstitial spaces of double - <br />walled containment sumps. <br />6.5.2 Purpose. This section describes the prep- <br />aration and procedures to test the integrity of con- <br />tainment sumps to ensure that they do not leak. <br />6.5.3 Description of Test. The containment <br />sump is filled to the proper level with water. The <br />water level is measured at the beginning and end of <br />the test. <br />6.5.4 Test Equipment. Test equipment shall <br />include: <br />• water; <br />• measuring stick that is accurate to within 1116 <br />(0.063) inch and of sufficient length; <br />• stopwatch or other time-a-easurement device <br />capable of measuring a I -second increment. <br />6.5.5 Preparation. <br />1. Care should be taken when conducting the test <br />in the rain or during freezing weather condi- <br />tions. <br />2. Remove and properly dispose of any liquid and <br />debris (leaves, sediment and trash) in the con- <br />tainment sump. <br />3. Inspect the containment sump for damage. <br />Examine all penetration fittings, conduits, junc- <br />tion boxes, caps and risers (if present), and side- <br />wall seams for defects, damage or improperly <br />installed components. If there are loose com- <br />ponents (e.g., loose penetration fitting clamps <br />or missing interstitial space caps), correct these <br />items before performing the integrity test. If <br />pei.org 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.