Laserfiche WebLink
4U'" U S A N 10 A Q U I N Environmental Health Department <br /> co <br /> 1 COUNTY Jasjit Kang , REHS , Director <br /> Greatness grows here . Muniappa Naidu , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Elena Manzo , REHS <br /> Natalia Subbotnikova , REHS <br /> September 27 , 2023 <br /> RYAN BROWNLEE <br /> ABLE MAINTENANCE INC <br /> 3224 REGIONAL PARKWAY <br /> SANTA ROSA, CA 95403 <br /> ryan@ablemaintenance . com <br /> Re : SAFEWAY FUEL CENTER # 1769 SR0086810 <br /> 2802 COUNTRY CLUB BLVD , STOCKTON , CA 95204 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace all product piping <br /> • Replace all UDCs ( under dispenser containment sumps) with conversion frames <br /> • Replace all turbine sumps <br /> • Replace all direct bury spill containers <br /> • Replace all overfill prevention flapper valve <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire district , the San Joaquin Valley Air Pollution Control District , and the local <br /> community development department for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for written approval <br /> prior to commencing work . All new submittals supersede previous ones . <br /> 3 . Email notification to ust(c.sjgov . orq to arrange the following inspection appointments . <br /> All appointments must be scheduled at least 48 hours in advance . <br /> a . Primary piping test : Soap test of all piping joints and penetrations ( product , vapor <br /> recovery , vent , and chase ) , and pressure testing — hydrostatically at 150 % of design <br /> operating pressure or pneumatically at 110 % of operating pressure . If the calculated <br /> test pressure is less than 40 psi , 40 psi shall be used as the test pressure . Testing must <br /> be conducted in accordance with manufacturer specifications and California Code of <br /> Regulations (CCR) Title 23 . <br /> b . Secondary piping test : Soap test of all piping and penetrations ( product , vapor recovery , <br /> vent , and chase) , and pressure test , in accordance with manufacturer specifications . <br /> c . Verification of secondary piping slope for all piping ( product , vapor recovery , vent , and <br /> chase ) at 1 /8 inch per foot or greater , to a containment sump with an audible and visual <br /> alarm . Piping slope must be adequate at the start of this inspection , with all piping in its <br /> final position and ready to be backfilled without adjustments per the manufacturer' s <br /> installation instructions . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 F 209 464-0138 1 www . sjgov . org/ehd <br />