Step 8 : (See Figure 3 & 4) adjustment nut is set at the factory , but due to <br /> Install adjusting system beneath tabs on mounting environmental conditions it may be necessary to <br /> ring . See Figure 3 for standard cover models . See adjust it to either improve sealing or ease cover <br /> Figure 4 for sealable cover models . Add shims as removal . <br /> needed and adjust with screw . ( Shims must be cut to <br /> size for sealable cover models . ) The height can be Important : Leave these instructions with Station <br /> increased up to 1 " (2 . 5cm) . Operator. <br /> Note : The adjustment should not be more than 1 It <br /> from <br /> the initial length of the unit. <br /> Step 9 : <br /> Upon preliminary installation perform the California <br /> Test Procedures TP-201 . 1 C or equivalent . Their Test -- <br /> Procedures will check the seals between the drain <br /> valve , nipple and rotatable adapter. To test the spill Height C- �- -� ' Shims <br /> containers base and bellows fill the container with Adjustment7 . . . .t - - -. - - - - - 7J <br /> water . A drop in the water level of 1 /16" or greater <br /> after one hour means that a leak exists . To determine - -- - -- -- - -- <br /> where the leak is , look for a steady stream of bubbles L--- - - - - Cap <br /> coming from one of the joints or water leaking on the Adapter <br /> outside of the bucket . NOTE : Do not drain the water Figure 3 ,,,# Standard Cover Model Height Adjustment <br /> into the UST after the test is complete . Water must be <br /> disposed of per local requirements for hazardous <br /> waste . If the leak cannot be corrected the spill <br /> container should be replaced with another. <br /> Step 10 : ( See Figure 2 ) 117 <br /> Before pouring concrete , place plastic over the cover <br /> and mounting ring protecting them from concrete <br /> splash . Double check that the unit is level and at <br /> proper grade height . Pour concrete per figure 2 . <br /> Ramp or dome the concrete away from the mounting <br /> ring . There should be a minimum of 1 " slope to finish Shims Must MTM <br /> e Cut rade . The concrete surface should start at the Adjustment Height <br /> g Bength T� Adjustment <br /> bottom edge of the watershed slots and tapered down Boit <br /> to grade level . <br /> NOTE: Do not stand on spill container before Use OPW <br /> concrete sets up. 116-7085 or <br /> plastic from cover after concrete has dried . to Pipe Cap <br /> Remove Nipple <br /> p to Support <br /> Remove adjustment system . Adaptor and tight fill cap Adjustment <br /> can now be installed in sealable cover models . System <br /> Retest the spill containers for leaks as described in <br /> step 9 , after the concrete has set up . Figure 4 - Sealable Cover Model Height Adjustment <br /> Operation and Maintenance : <br /> Annually : Inspect and clean the interior of the spill <br /> container and drain valve screen . Remove <br /> accumulated dirt and grit . Test the drain valve using <br /> CARB procedure TP -201 . 1 C or TP-201 . 1 D . If the <br /> drain valve passes testing no further maintenances <br /> required . If the drain valve fails testing , remove the <br /> valve , soak in water and use high -pressure air, if <br /> needed , to clean . Reinstall the drain valve to its <br /> proper position and test the valve with CARB <br /> procedure TP-201 . 1C or TP-201 . 1 D . If problems <br /> persist , replace the drain valve with P/N 1 DK-2100- <br /> EVR (specified torque 11 . 5 ft- lbs min to 13 . 5 ft-lbs <br /> max , 5/ 16- 18 UN thread ) . The sealable cover ( 1SC ) <br /> OPW 1 -2100 Series Spill Container Page 3 <br />