My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SNEDEKER
>
809C
>
2800 - Aboveground Petroleum Storage Program
>
PR0528437
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2023 4:47:04 PM
Creation date
4/3/2023 8:30:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0528437
PE
2833
FACILITY_ID
FA0018706
FACILITY_NAME
CANARY RENEWABLES CORP
STREET_NUMBER
809C
STREET_NAME
SNEDEKER
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
APN
16203007
CURRENT_STATUS
01
SITE_LOCATION
809C SNEDEKER AVE
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
490
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PAGE OF <br />* If box is blank, Manufacturer shall determine and submit as per Appendix L. <br />30.Floating Roof Selection <br />Design Basis: Appendix C Or Appendix H <br />Type of Roof:(External or Internal):Single Deck Pontoon* Double Deck* <br />(Internal Only): Tubular Pontoon* Metallic Sandwich Panel* <br />Other Supplemental Spec.: <br />31.Seals <br />Primary Seal: Shoe Envelope Wiper/Compression Plate Other Supplemental Spec.: <br />Shoe Mechanism: Mfg. Std. Other <br />Electrically Isolate Mechanism from Shoes? Yes No Wax Scrapers Required? Yes No <br />Minimum Shoe Thickness* Carbon Steel Shoes to be Galvanized?Yes No <br />Secondary Seal: Shoe Envelope Wiper None Other Supplemental Spec.: <br />32.Data for All Floating Roofs: <br />Overflow Openings in Shell Acceptable? Yes No Shell Extension? Yes No <br />Roof-Drain Check Valves Required? Yes No Roof-Drain Isolation Valves Required? Yes No <br />Freeze Protection for Roof Drains Required?No Yes Supplemental Requirements: <br />Roof-Drain Piping to External Nozzles: Mfg. Std. Armored Flexible Pipe Swivels in Rigid Pipe Other <br />Foam Dam? Yes No Supplemental Spec.: <br />Minimum Deck Thickness* <br />Bulkhead Top Edges to be Liquid-Tight? Yes No Seal-Weld Underside of Roof? Yes No <br />Electrical Bonding:Shunts:Yes No Cables: Yes No Supplemental Spec.: <br />Qty. of Non-Guide-Pole Gauge Wells Required Qty. of Sample Hatches Required <br />Guide Pole for Gauging? Yes No Slots in Guide Pole?No Datum Plates?Yes No Striking Plates? Yes No <br />Guide Pole Emissions-Limiting Devices: Sliding Cover Pole Wiper Pole Sleeve Float Float Wiper Pole Cap <br />Qty. of Roof Manholes*Minimum High-Roof Clearance Above Bottom: <br />Removable Leg Storage Racks?Yes No ;Leg Sleeves or Fixed Low Legs <br />33.Additional Data for External Floating Roofs: <br />Weather Shield? Yes No Supplemental Spec.: <br />Rolling Ladder Required? Yes No Field Adjustable Legs? Yes No <br />Design Rainfall Intensity in./hr. (mm/hr) Based on a Minute Duration Associated with the Storm <br />Design Accumulated 24-Hour Rainfall in. Based on the Storm <br />Distortion and Stability Determinations Required? Yes No Supplemental Specification <br />Landed Live Load* <br />Approvals:Revisions:Title: <br />By: Ckd: Date: <br />Drawing No.: Sheet of <br />FLOATING ROOF DATA (This section is not applicable to this job) <br />Yes <br />I.CASTILLO <br />86 <br />API Std 650 Storage Tank <br />Data Sheet <br />10/28/14
The URL can be used to link to this page
Your browser does not support the video tag.