My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2024 1:59:31 PM
Creation date
6/28/2023 4:20:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for H&M - BW#98 as of December 27, 2023. <br /> Open violations from July 19, 2023 inspection <br /> Violation#104-Failure to submit a complete and accurate UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. The 91 leak detector on <br /> CERS is listed as a VMI. On site a Red Jacket leak detector was observed in the 91 STP sump. <br /> REGULATION GUIDANCE:The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#118-Failure to submit the "Overfill Prevention Equipment Inspection Report Form"within 30 <br /> days. <br /> OBSERVATION: An overfill prevention equipment inspection was performed on 3/25/2023 & 3/28/2023.A test <br /> report has not been submitted to the EHD or the California Environmental Reporting System (CERS). <br /> REGULATION GUIDANCE:A copy of the inspection report form must be submitted within 30 days of the test. <br /> CORRECTIVE ACTION: Immediately provide this report to the EHD. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#120-Failure to submit and/or maintain documentation regarding compatibility for UST system <br /> components. <br /> OBSERVATION:A statement of compatibility for the 91 premium has not been submitted for the Red Jacket FXIV. <br /> REGULATION GUIDANCE: Since the independent testing organization for the Red Jacket FXIV did not include a <br /> statement of compatibility for the 91 premium product to be used with the Red Jacket FXIV, a written, affirmative <br /> statement of compatibility for the 91 premium product from the manufacturer shall be submitted. <br /> CORRECTIVE ACTION: Immediately submit an affirmative statement of compatibility or replace the 91 premium <br /> product with a component that meets all applicable Title 23 requirements for a UST system. <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.