My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 9:31:25 AM
Creation date
9/6/2023 1:22:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231348
PE
2361
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
01
SITE_LOCATION
601 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ :SUPER <br /> ANNUAL TEST FAIL LEAK MIN PERIODIC: 'Q 0% DISPENSE MODE: <br /> ALARM DISABLED l� 0 STANDARD <br /> SENSOR: NON-VENTED <br /> PERIODIC TEST FAIL \ LEAX M I PJ AP-Ur•JUAL 0% PRESSURE OFFSET: O.OPS I <br /> ALARM'DISABLED' 0 <br /> MECHANICAL BLENDER: NO <br /> GROSS TEST FAIL PERIODIC TEST TYPE <br /> ALARM DISABLED STANDARD <br /> ANN TEST AVERAGING: OFF ANNUAL TEST FAIL <br /> PER TEST AVERAGING: OFF ALARM DISABLED <br /> TANK TEST NOTIFY: OFF <br /> I PERIODIC TEST FAIL <br /> TNK TST SIPHON BREAKOFF ALARM DISABLED <br /> DELIVERY DELAY 1 MIN <br /> GROSS TEST FAIL <br /> PUMP THRESHOLD 10.00% ALARM DISABLED G 2:REGULAR <br /> I <br /> ANN TEST AVERAGING: OFF TYP:2.0/3.0IN FIBERGLASS <br /> PER TEST AVERAGING: OFF 2.OIN DIA LEN: 350 FEET <br /> i <br /> TANK TEST NOTIFY: OFF 3.OIN DIA LEN: 0 FEET <br /> TNK TST SIPHON BREAKOFF SHUTDOWN RATE: 3.0 GPH <br /> DELIVERY DELAY 1 MIN LOW PRESSURE SHUTOFF:NO <br /> PUMP THRESHOLD 10.00 LLW PRESSURE 0 PSI <br /> T 2:REGULAR <br /> T 4:DIESEL DISPENSE MODE: <br /> PRODUCT CODE 4 STANDARD <br /> THERMAL COEFF : .000450 SENSOR: NON-VENTED <br /> TANK DIAMETER 95.75 PRESSURE OFFSET: O.OPSI <br /> TANK PROFILE 4 PTS <br /> FULL VOL 1015' MECHANICAL BLENDER: NO <br /> 71 .8 INCH VOL 8175 <br /> 47.9 INCH VOL : 5098 <br /> 23.9 INCH VOL 2005 <br /> FLOAT SIZE: 4.0 IN. LEAK TEST METHOD <br /> WATER MINIMUM 0.000 <br /> TEST ON DATE ALL TANK <br /> WATER WARNING 2.0 FEB 6, 2007 <br /> HIGH WATER LIMIT: 3.0 START TIME : DISABLED <br /> WATER ALARM FILTER: LOW TEST RATE :0.20 GAL/HR <br /> DURATION 2 HOURS G 3:REGULAR <br /> MAX OR LABEL TST EARLY STOP:LrISABLED TYP:2.0f3.OIN FIBERGLASS <br /> VOLUME 10152 i LEAK TEST REPORT FORMAT 2.OIN DIA LEN: 350 FEET <br /> HIGH PRODUCT NORMAL 3.0IN DIA 'LEN: 0 FEET <br /> MAX 95.0 <br /> (GALLONS) 9644 SHUTDOWN RATE: 3.0 GPH <br /> LOW PRESSURE SHUTOFF:NO <br /> OVERFILL LIMIT LOW PRESSURE 0 PSI <br /> i MAX .: 90.0 <br /> (GALLONS) 9137 3:REGULARPENSE <br /> DELIVERY'LIMIT STANDARD <br /> . % MAX 5.0 SENSOR: NON-VENTED <br /> (GALLONS) : 508 PRESSURE OFFSET: O.OFSI <br /> LOW PRODUCT PRESSURE LINE LEAK SETUP MECHANICAL BLENDER: NO <br /> VOLUME 500 t - - - - - - - - <br /> LEAK ALARM LIMIT: 99 Q 1 :SUPER <br /> SUDDEN LOSS LIMIT: 99 <br /> TANK TILT 0.00 T4'P:2.03.OIN FIBERGLASS <br /> PROBE OFFSET '0.9� 2.OIN DIA LEN: 350 FEET <br /> SIPHON MANIFOLDED TANKS 3.OIN DIA LEN: 0 FEET <br /> Tit: NONE SHUTDOWN RATE: 3.0 GPH <br /> LINE MANIFOLDED TANKS LOW PRESSURE SHUTOFF:NO <br /> Tit: NONE LOW PRESSURE 0 PSI <br />
The URL can be used to link to this page
Your browser does not support the video tag.