Laserfiche WebLink
L 9:87 2 STPIN-TANK ALARMS <br /> f Q 5:DIESEL TRI-STATE (SINGLE FLOAT) ALL:OVERFILL ALARM <br /> CATEGORY : STP SUMP I ALL:HIGH PRODUCT ALARM TYP:2,0.�3.OIN FIBERGLASS �� ALL:MAX PRODUCT ALARM <br /> 2.OIN DIA LEN: 350 FEET <br /> 3.0IN DIA LEN: 0 FEET L10:87 1 STPTRI-STATE (SINGLE FLOAT) <br /> SHUTDOWN RATE: 3.0 GFH <br /> CATEGORY : STP SUMP <br /> LOW. PRESSURE SHUTOFF:NO <br /> LOW PRESSURE : 0 PSI L11 :DIESEL STP <br /> T 4:13iESEL TRI-STATE (SINGLE FLOAT) <br /> DISPENSE MODE: CATEGORY : STP SUMP <br /> STANDARD <br /> SENSOR: NON-VENTED L12:DISP 1-2 PLLD LINE DISABLE SETUP <br /> PRESSURE OFFSET: 0.OPSI TRI-STATE (SINGLE FLOAT) - - - - - - - - - - - - <br /> MECHANICAL BLENDER: NO CATEGORY DISPENSER PAN <br /> Q 1 :SUPER <br /> IN-TANK ALARMS <br /> L13:DISP 3-4 t. ALL:HIGH WATER ALARh9 <br /> TRI-STATE (SINGLE FLOAT) I <br /> CATEGORY : DISPENSER FAN LIQUID SENSOR ALMS <br /> L 8:FUEL ALARM <br /> L.12:FUEL ALARM <br /> L13:FUEL ALARM <br /> L14:DISP 5-6 L14:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L15:FUEL ALARM <br /> CATEGORY : DISPENSER PAN L16:FUEL ALARM <br /> L17:FUEL ALARM <br /> LINE LEAK LOCKOUT SETUP L, 8:SENSOR OUT ALARM <br /> - - - - - - - - - - - - L12:SENSOR OUT ALARM <br /> LOCKOUT SCHEDULE j L15:DISP 7-8 L,13:SENSOR OUT ALARM <br /> DAILY TRI-STATE (SINGLE FLOAT) L14:SENSOR OUT ALARM <br /> START TIME: DISABLED CATEGORY : DISPENSER PAN L15:SENSOR OUT ALARM <br /> STOP TIME : DISABLED L.16:SENSOR OUT ALARM <br /> L17:SENSOR OUT ALARM <br /> L 8:SHORT ALARM <br /> L16:DISP 9-10 L12:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) ; L13:SHORT ALARM <br /> ' CATEGORY : DISPENSER PAN L14:SHORT ALARM <br /> j L15:SHORT ALARM <br /> 1 L16:SHORT ALARM <br /> 1 L17:SHORT ALARM <br /> L17:DISP 11-12 <br /> TRI-STATE (SINGLE FLOAT) ISD SITE ALARMS <br /> CATEGORY DISPENSER PAN ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL <br /> I LIQUID SENSOR SETUP _ ISD VAPOR LEAK FAIL <br /> - - - - - - - - ISD VP FRES FAIL <br /> ISD VP STATUS FAIL <br /> L 1 :91 ANN ISD SETUP FAIL <br /> NORMALLY CLOSED ISD SENSOR OUT FAIL <br /> I CATEGORY : ANNULAR SPAi_E <br /> ISD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL <br /> i ALL:DEGRD COLLECT FAIL <br /> L 2:87 2 ANN ALL:FLOW COLLECT FAIL <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : ANNULAR SPACE Q 2:REGULAR <br /> OUTPUT RELAY SETUP <br /> - - - - - - - - - - - - LIQUID SENSOR ALMS <br /> L 9:FUEL ALARM <br /> L 3:87 1 ANNR 3:REN1OTE ALARM L10:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) TYPE: L12:FUEL ALARM <br /> CATEGORY ANNULAR SPACE MOMENTARY 1.13:FUEL ALARM <br /> NORMALLY CLOSED L.14:FUEL ALARM <br /> L.15:FUEL ALARM <br /> L 4:DIESEL ANN L16:FUEL ALARM <br /> IN-TANK ALARMS I L17:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) ALL:OVERFILL ALARM L 9:SENSOR OUT ALARM <br /> CATEGORY : ANNULAR SPACE ALL:HIGH PRODUCT ALARM L,IO:SENSOR OUT ALARM <br /> ALL:MAX PRODUCT ALARM L12:SENSOR OUT ALARM <br /> L13:SENSOR OUT ALARM <br /> R 4:ALARM L,14:SENSOR 'OUT ALARM <br /> L 8:91 STPTpE; L15:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) MOMENTARY L16:SENSOR OUT ALARM <br /> CATEGORY : STP SUMP NORMALLY OPEN L,17:SENSOR OUT ALARM <br />