DISPENSER 28.7 26.9 AGCDC.COM <br /> 3'-77/6" SKINA 15.1 15.1 31.8 v 23.8 a <br /> 3'-7 Y4" INSIDE1„ N.P.T. VAPOR CABLE TO VAPOR PRESSURE Z_1 -1/2"N.P.T. INLET (3) 1'-5" 1'-5" RECOVERY OUTLET, JUNCTION BOX SENSOR <br /> (OPTIONAL) 2—WAY VAPOR FLOW ~ <br /> CALIBRATION SENSOR I : I W <br /> op p o VALVE <br /> rn V <br /> 1" SHORT VAPOR SHEARVALVE <br /> o Z <br /> — NIPPLE FUEL WHIP HOSE 0 <br /> 00 STABILIZER z U <br /> ASSEMBLY w I Z <br /> 1/4" OD REDUCE THREADS I C/) FUEL HOSE BREAKAWAY <br /> COPPER TUBING. FROM 1-1/2 TO �I <br /> Ld <br /> AVOID ANY 1/4" W/ DOUBLE NOTE: J p CO <br /> O co O TRAPS! (BY TAP BUSHING(S) CAT 5 CABLE SHALL BE INSTALLED o w ° 0 <br /> FOR BOTH ENHANCED OR STANDARD z coLO <br /> CONTRACTOR) VAPOR RETURN 'L J > "' <br /> ELECTRONICS p 0 rn M <br /> (REGULAR)—/ /8" x 2" SLOTS FOR ANCHOR BACK TO TANKS w Cu Q CN <br /> PRODUCT 1BOLTS, 6 SPACES CONTAINMENT I v � <br /> 101/2 1'-1" w I <br /> PRODUCT #2 (PREMIUM) SUMP z w Q p co .co CO <br /> JUNCTION BOX 12 X 12 STEEL irl 0 o Q <br /> SIDE "A" VST PHASE II W/ VEEDER—ROOT ISD 5 <br /> CANOPY COLUMN <br /> SCALE: NTS BALANCE PHASE II SYSTEM w v 0- <br /> N (o > 0- <br /> 4" <br /> 4" PVC CANOPY 0 <br /> A—A DISPENSER MOUNTING DIAGRAM DRAIN EACH COLUMN GILBARCO 3+0 <br /> SCALE: 1"=l'—O" I o °0000° BLENDER <br /> (1) 1" CONDUIT TO I '°°°°° m <br /> EACH COLUMN <br /> — — o0 <br /> -H SAFETY NOTE: a' <br /> M WHEN DISPENSERS ARE INSTALLED I NOZZLE (TYP.) <br /> DISPENSER SUMP FRAME / I \ co AS SHOWN ON THIS DRAWING, THE <br /> (ADJUSTABLE HEIGHT) REQUIREMENTS OF NFPA 30A 6.3.9 <br /> / \ AND 6.3.9.1 REGARDING SHEAR I I FUEL HOSE <br /> SECTIONS ARE FULLY MET. <br /> wElElO <br /> C o C o 0 0 <br /> w ■ <br /> U O <br /> I <br /> J I I z <br /> o <br /> ° LJ0o SEE BOLLARD <br /> Q DETAIL ON w <br /> SHEET G.0.5 d <br /> RUN CONDUITS THROUGH D <br /> Q I <br /> N <br /> OFFSET CAVITY IN o <br /> DISPENSER SUMP FRAME <br /> I 411.5 1 <br /> NOTE: CONDUITS SHALL NOT <br /> PENETRATE SUMP. ROUTE (TYPEXPANSION JOINT 4,000 PSI <br /> THROUGH OFFSET FRAME CON SEE FIBERMESH <br /> CAVITY. DO NOT CUT SIDE NOTE: CONCRETE DETAILS CONCRETE MIX <br /> PANELS OF DISPENSER CONCRETE SLAB ° SHEET M.5.3.27 <br /> B—B DISPENSER CONTAINMENT SUMP PLAN VIEW 1. ONLY (1) VAPOR PRESSURE - FOR DETAIL I ^ I. ° <br /> SCALE: 1" = 1'-0" SENSING DEVICE REQUIRED C° a <br /> PER SITE. SENSOR SHALL BE ° a . ° a ° < a.. w <br /> MOUNTED AT ONLY (1) ^ ° a a . a <br /> 2—IN-1 SENSOR DISPENSER LOCATED CLOSEST a ° CO a J ° 4 ° C° 4 ° a <br /> BOX TO TANKS. I I <br /> SUMP SENSOR 2. CONTRACTOR SHALL PITCH ALL II <br /> J—BOX d o <br /> ❑ DISPENSER 1/4" TUBING AS REQUIRED TO J < I I ° a Z <br /> DISPENSER SKIN ' ' J—BOX AVOID ANY LIQUID TRAPS < � EXPANSION <br /> PRODUCT SHEAR P v OPTIONAL STORM DRAIN JOINT (TYP.) <br /> VALVE (TYP.) u ROUTING, SEE CIVIL SITE SEE CONCRETE a <br /> PLAN FOR ACTUAL DETAILS SHEET a = <br /> ELBY CAPPED D I a. a a <br /> ELBOW (TYP.) PIPING UNIONS II — — ROUTING AND I _ <br /> w M.5.3.27 FOR Q <br /> SEAL OFF (TYP.) BY GILBARCO w i CONTINUATION I / — I DETAIL <br /> Cn <br /> o <br /> VAPOR SHEAR VALVE z /�\/�\/�\/�\/� <br /> z_ w <br /> ° a m <br /> I r� <br /> ° ° ° ° X e » w <br /> 1" INTERCOM °' 3 �8 <br /> CONDUIT <br /> BRINE RESERVOIR & <br /> ° e n � ° d J n e e n ° d , DISPENSER CONTAINMENT <br /> 1 POWER/DATA HYDROSTATIC SENSOR ° . I I. ° m a ° ° I I ' d , ' I I. m ° ° ° d ° *MINIMUM RECOMMENDED SUMP <br /> CONDUIT ATTACHED TO SUMP a< • .� a< • ° <br /> 1" MONITORING J ° ° d ° ° ° • ° J ° ° d ° ° ° ° ° DIMENSION. SEE NOTE BELOW Q <br /> x18 (TYPICAL)ED OR NATIVE SOIL <br /> „ » Q • • • Q a • ° ° M <br /> CONDUIT CONNECTOR ° ° ° : ° ° . : a d °° ° d U ° ° ° ° ° ' + ° d <br /> ° d ° ° d II II II �� <br /> 2" INSIDE 3" FRP 3" INSIDE 4" FRP ° ° ° ° ° ° NOTE: <br /> PRODUCT LINE VAPOR LINE cn ° d °° G ° ° � e d °• a ° ° IF REQUIRED BY LOCAL O <br /> 3" D.W. FRP BONDED ENTRY FITTING — CODES, EXTEND CONCRETE <br /> W/ 4"x3" CONCENTRIC REDUCER W/ �J d ° ° ° • ° ° ° ° LJJ d • ° ° ° ° ° ° • ° v <br /> ° ° ° • ° ° °° I I d �. a °J I ° ° • ° ° °° d UNDER BOLLARD BELOW THE <br /> TEST PORT & 1/4" PLUG (TYP.) u ° ° a ° ° u ° ° a d ° ° ° ° FROST <br /> LIN <br /> DOUBLE WALL UNDER d ' • d d ° d (- <br /> SUMP SENSOR IN <br /> HOLDER DISPENSER I� (SEE STRUCTURAL) � T (SEE STRUCTURAL) PROJECTION OF ADA REQUIRED <br /> CONTAINMENT SUMP FRONT ELEVATION m <br /> C—C: FRONT VIEW SECTION DETAIL @ DISPENSER SUMP DISPENSER ON ISLAND INSTALLATION DETAILS SIDE ELEVATION I NOTE: CANOPY FOOTINGS CAN BE VERY � J <br /> SCALE: 1"-1'-0" SCALE: 1" = 1'-0" LARGE AND CAN VARY IN SIZES. SEE <br /> STRUCTURAL DRAWINGS. Il <br /> ADA PLATFORM (NTS SEE BELOW) J <br /> NOTE: IF THERE IS NO ROOM TO INSTALL THE *MINIMUM RECOMMENDED <br /> VAPOR FLOW METER ABOVE THE SHEAR VALVE, DIMENSION. SEE NOTE BELOW / i �33�'—:8 <br /> IT IS ACCEPTABLE TO INSTALL FLOW METER "B" SIDE OF DISPENSER <br /> BELOW SHEAR VALVE PER LATEST EDITION OF 2'-6" 2'-6" 1 <br /> E.O. VR-202 ON HEALY SOLUTION & E.O. / � CILw <br /> VR-204 ON VST SOLUTION. SEE MOST RECENT <br /> VEEDER ROOT INSTALLATION INSTRUCTIONS FOR 2—IN-1 SENSOR BOX I DISPENSER LINE OF CANOPY 1 Y4 SIDE "B" <br /> ISD FLOW METERS I I�� COLUMN / z U <br /> GILBARCO DISPENSER FRAME VAPOR FLOW SENSOR SUMP SENSOR J—BOX I I � <br /> PRODUCT SHEAR VALVE ELBY CAPPED ELBOW (TYP.) BRINE RESERVOIR & pu <br /> W <br /> 1-1/2"x18" FLEX CONNECTOR HYDROSTATIC SENSOR 0 J <br /> SEAL—OFF (TYP.) � EXACT LOCATION � <br /> W <br /> I ATTACHED TO SUMP 1 w <br /> VAPOR SHEAR VALVE I I I o C, ^ SUBJECT TO AUTHORITY (-D = Z� O 7 <br /> RUN CONDUITS THROUGH I I OPTIONAL STORM DRAIN z w _ HAVING JURISDICTION. <br /> ° a OFFSET IN DISPENSER I i DISPENSER JUNCTION ROUTING, SEE CIVIL SITE SIJ JIB oI z <br /> SEE BOLLARD DETAIL w <br /> BOX (TYP.) w o I ON SHEET G.0.5 <br /> Cl— <br /> SUMP FRAME (TYP.) I I PLAN FOR ACTUAL ROUTING I z v � Q <br /> � E � AND CONTINUATION w w I z w � � <br /> 3„ D.W. FRP BONDED ENTRY I I\ u O w z <br /> FITTING W/ 4"x3" CONCENTRIC ° I —=_ 1 / o <br /> REDUCER W/ TEST PORT & SENSOR MOUNTING LINE OF FOUNDATION CD O Q <br /> 1/4” PLUG (TYP.) SUMP SENSOR IN HANGER KIT (TYP.) BELOW. (SEE <br /> HOLDER ���\ ��� STRUCTURAL) <br /> 3" INSIDE 4" FRP \ consultant job# <br /> RECOVERY LINE 1" DISPENSER SIDE "A" <br /> INTERCOM e `J \ master release date <br /> • TEST PORT AT UDC CONDUIT I <br /> project master <br /> 3'-7y2" exe date drawn by <br /> 1" DISPENSER <br /> ° — POWER & DATA <br /> 2" INSIDE 3' FRP ° ° ° oho 0 — DISPENSER ISLAND , <br /> PRsDUCT LINE 0 "0D0° o^°_ o 0 0- 04Mo4M°4Mo4� CONDUIT (NP ) 5 —0 <br /> W6_ <br /> V° o()o(J°U°U�U�U�v�Q0 O o 0 0�" 0 0 0 0 0 0 oT' » <br /> 00W° N ° ��0° 1 MONITORING SUMP MONITOR * NOTE: THESE DIMENSIONS REPRESENT MINIMUM RECOMMENDED <br /> _ LIQUID SENSOR OFFSET DIMENSIONS TO PROVIDE DESIRED CLEARANCE OF THE Facility/Project <br /> 2" FRP ELBOW WITH I I I I_I = COMPACTED OR NATIVE CONDUIT DISPENSER VALENCE FROM THE COLUMN AND ARE BASED ON A <br /> PEA GRAVEL 2" FRP X 1-1/2" SOIL (TYPICAL) MAXIMUM 12"X12" NON—CLADDED COLUMN DESIGN. WHERE ADA REQUIRES 48"x30" MIN. AREA IN FRONT OF <br /> FNPT BUSHING DOUBLE WALL UNDER DISPENSER ARCHITECTURAL COLUMN WRAPPING IS REQUIRED THE 1'-4 1/4" BOTH SIDES OF MPD, SLOPE NOT TO EXCEED 2%.� <br /> CONTAINMENT SUMP <br /> MINIMUM FACE TO FACE DIMENSION SHALL TAKE PRECEDENCE. THERE SHALL BE A 10" MIN DISTANCE FROM THE sheet name <br /> EDGE OF PLATFORM TO DISPENSER FACE FOR SID n /� • . <br /> D—D — SIDE VIEW SECTION @ DISPENSER SUMP DISPENSER CONTAINMENT SUMP CONDUIT ROUTING DETAIL DISPENSER ON ISLAND PLAN VIEW REACH M <br /> 23 <br /> SCALE: 1"=l'—O" I SCALE: NONE SCALE: 1"=1'-0" /1///////1//////L/ <br /> SUMP SENSOR IN <br />