My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FINAL WMU FU-23 DESIGN RPT & CONCURRENCE LTRS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
2023-2025 Reports
>
COMPLIANCE INFO_FINAL WMU FU-23 DESIGN RPT & CONCURRENCE LTRS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 8:51:58 AM
Creation date
11/30/2023 9:10:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
FINAL WMU FU-23 DESIGN RPT & CONCURRENCE LTRS
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
257
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> Page 16 <br /> <br /> <br />TABLE 3-8 <br />General Earthfill Material Acceptance Testing <br /> <br />Test <br /> <br />Method <br />Proposed <br />Frequency <br /> <br />Proposed Criteria <br />Particle Size D422, D1140 5,000 cy 3" max. particle size; ½ “ max at surface <br />Compaction Curve ASTM D1557 5,000 cy or <br />change in <br />material <br />N/A <br />Atterberg Limits D4318 5,000 cy <br /> <br />No specified requirements <br />Density and Water <br />Content <br />Nuclear Gage D2922 500 cy Minimum 90% relative compaction at moisture <br />content within 3 percent of optimum moisture content <br />Water Content Oven D2216 (with <br />cor. To Nuclear Gage <br />D2922) <br />5,000 cy Within 3% of optimum moisture content <br /> <br /> <br />3.2.3 Soil Sample Numbering <br /> <br />The QA/QC Inspectors maintain soil sample numbers in a master log maintained at the site. Sample <br />numbers begin with (001) and proceed upward. No sample number can be repeated, and re-tests of a <br />failing sample are given the original number with a letter suffix (i.e., re-tests for a failing sample 021 <br />would be: 021A, 021B,etc.). Information contained in the master log of test samples includes: <br /> <br />• Sample number <br />• Test(s) to be performed <br />• Date sampled <br />• Inspector obtaining sample <br />• Location sampled <br />• Location to testing (site vs. off site) <br />• Date sample sent off site <br />• Date test results received <br />• Site testing Inspector <br />• Date testing completed at site <br />• Test results and remarks <br /> <br />3.2.4 Soil Sample Tagging <br /> <br />The QA/QC Inspector is responsible for maintaining sample identification for all soil samples while <br />on site, from time of sampling through completion of testing. The QA/QC Inspector must place a <br />sample tag on the soil sample container immediately upon sampling. The tag must remain with the