PR0231906
PE
2361 - UST FACILITY
FACILITY_ID
FA0003776
FACILITY_NAME
KWIK SERV LODI BW 113*
STREET_NUMBER
420
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06202042
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
420 W KETTLEMAN LN LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />F -e -alt -h Dec,-a-t-rnent <br />Underg-found Stnrar?A T;tr-k Pmgram Inspection R-epo-, <br />Facility RUM: Faciii-ty, Address: <br />Date-, <br />K�'--"K SERV LOD! BW I !,� N. 0-- <br />Janua-v 11, 2024 <br />SUMMARY OFVIOLA TIONS <br />(CLASS i. CLASS 1L or MNOR - N-GtkCe to Ccinpiy) <br />Item # <br />Remarks <br />205 <br />CCR 2712(i) Failure to submit and have current LIST Monitoring Plan readily accessible at the facility. <br />OBSERVATION: Ar uprated copy of the diesel monitoring plans were nm available for inspect -ion- The monitoring <br />plan lists the VR -409 as the annular sensor for the diesel tank, but it is utilizing the VR -3413 annular sensor. <br />REGULATION GUIDANCE: A copy of these monitoring plans shall be accessible on site at all trnes. <br />CORRECTIVE ACTION: Immediately update the monitoring plan and retain a copy on site. <br />This is a repeat violation, 'Class 11. <br />208 <br />CCR 2716(a -e) Failure to comply ;kith the designated operator inspection requirements. <br />OBSERVAT !ON: —ine designated operator failed to check and note all required items on the visual -inspection <br />reports. The incorrect and missing information included the following from the inspection reports: <br />- UDC 9/10 was not included in the visual inspection reports. <br />- DO reports did not indicate that sumps with fuel alarms were visually inspected. <br />- Secondary Containment Test Data is incorrect, the correct date is 01/1512021. <br />- DO indicated that hav;na a qualified technician observe the sumps with fuel alarms was not applicable vrhen there <br />were fuel alarms. <br />REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required <br />tesbng and maintenance for th:e UST system have been completea and shall check a,', required items on the report. <br />CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br />all of the required info oration on 'the reports. <br />OBSERVATPON: The designated opera-ci- failed to document ali the alarms from the attached alarm history or t <br />I <br />March, May and December designated operator inspection reports and failed to check that they were responded to <br />appropriately. The missing alarms include: L1 87 STP sump setup/data warning on 02127/2022, the L9 UDC Ili <br />setup/data warning or, 04/17/2023. and the C' diesel e85 fjel alarm on 04.'19;2023. <br />REGULATION GUIDANCE-- During the mispection, the designated operator sriall review the alarm history since the <br />previous inspection. check that each alarm was documented a7rd responded- tc appropriately, and attach a copy of <br />ij the alarm history with documentation taken in response io anv alarrrs too the inspection report. <br />CORRECTIVE ACTION: Ensure that designated operamrs performing inspections at this facility are including all of <br />the required information on the reports. jI <br />This sa moeat v;o1ation- Class <br />FADW3"6 PFU231--S-Zr6 S-0201, vll 17 ZC2= <br />EM 23-0-1 RvA. 121M=1 Pop 6 Of 9 Umerground Su,-aoe Tank Prowam OIR <br />.� ! . — - Z�j - <br />1.868 E. Hazelton Averue'� Stolckt r., Califorma 9_205' T 909 Z168-3420 1 F 209 464-313,8 i <br />
The URL can be used to link to this page
Your browser does not support the video tag.