My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5920
>
4100 – Safe Body Art
>
PR0548004
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2025 3:24:30 PM
Creation date
3/5/2024 9:14:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4100 – Safe Body Art
File Section
COMPLIANCE INFO
RECORD_ID
PR0548004
PE
4121 - BODY ART FACILITY-STERILIZATION
FACILITY_ID
FA0027381
FACILITY_NAME
LOST DREAMS TATTOOS & PIERCING (CARTER, MICHAEL)
STREET_NUMBER
5920
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
5920 PACIFIC AVE STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
180
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(a) Open sterilizer door. Then, <br />remove dam gasket (1) and <br />door gasket (2) from <br />door (3). <br />(b) Clean the gaskets (1 and 2) <br />with a mild detergent and <br />inspect the gaskets for <br />cracks, cuts, shrinkage, or <br />swelling. Replace gaskets if <br />necessary. <br />(c) Clean the gasket housing <br />channel (A) with a solution <br />of mild soap and distilled or <br />demineralized water. A <br />small brush (not wire brush) <br />may be used to aid the <br />cleaning. <br />(d) Press the door gasket (2) <br />into the channel (A). Then, <br />install dam gasket (1). <br />3) (A <br />(e) Run one cycle to seat the gaskets properly. <br />Troubleshooting Guide <br />MA438700 <br />Use the following table to assist in correcting minor problems with the sterilizer. <br />Problem <br />WATER LOW lamp in <br />on. <br />DOOR AJAR lamp is on. <br />ERROR lamp is on. <br />Steam is escaping from <br />the pressure relief valve. <br />Troubleshooting Guide <br />Possible Cause <br />not enough water in <br />reservoir tank to fill <br />chamber. <br />Chamber door is not fully <br />closed and / or latched. <br />pressure relief valve was <br />not properly reseated after <br />pressure relief valve <br />inspection <br />Solution <br />add distilled or <br />demineralized water to <br />reservoir tank. <br />Close the door properly and <br />make sure the door is fully <br />latched. <br />See Error Code Guide for a <br />detailed explanation <br />Reseat the pressure relief <br />valve (see Perform Pressure <br />Relief Valve Check under <br />Monthly maintenance in this <br />manual). <br />
The URL can be used to link to this page
Your browser does not support the video tag.