Laserfiche WebLink
N SA NUJ OAQ U I N Environmental Health Department <br /> P <br /> COUNTY Jasjit Kang , REHS , Director <br /> cg4 ; j Greatness grows here . Muniappa Naidu , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Elena Manzo , REHS <br /> Natalia Subbotnikova , REHS <br /> August 21 , 2024 <br /> Matt Thomas <br /> CGRS , Inc . <br /> 5444 Dry Creek Rd <br /> Sacramento , CA 95838 <br /> mthomas@cgrs . com <br /> UST RETROFIT — FULL PERMIT APPROVAL <br /> Re : H & M — BW #98 SR2400400 <br /> 2501 Jackson Ave , Escalon , CA 95320 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace the diesel spill container (with a double walled spill container) and diesel drop tube <br /> with shut- off valve (flapper) <br /> • Cold start for cold start conducted on 11 / 14/2023 ( Failure to Obtain a Permit) <br /> • Verification for 87 leak detector replacement on 1 /2/2024 ( Failure to Obtain a Permit) <br /> • Remove ball float on 87 product tank ( part of SR0084893) <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire district , the San Joaquin Valley Air Pollution Control District , and the local <br /> community development department for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for written approval <br /> prior to commencing work . All new submittals supersede previous ones . <br /> 3 . Email notification to ustAsigov . orq to arrange the following inspection appointments . All <br /> appointments must be scheduled at least 48 hours in advance . <br /> a . Corrosion protection on the diesel spill bucket : Verify corrosion for direct spill bucket prior to <br /> backfilling . <br /> b . Spill bucket test on the diesel spill bucket : Verify minimum 5 -gallon capacity . Pass a one <br /> hour hydrostatic test ( or equivalent) . Verify proper drainage method . <br /> c . Verification of diesel overfill prevention : Measurement of drop tubes to verify 95 % tank <br /> volume shut off, verification of external audible/visual alarm activation when tank is 90 % <br /> full , or other approved method . Ensure that all pertinent tank charts and calculations are <br /> available for review at the time of inspection . <br /> d . Verification that ball float(s ) , if installed , do not interfere with the installed flapper valve for <br /> the 87 and diesel tank . <br /> e . Leak detector test on the 87 tank : Verify the device can detect a leak of 3 gallons per hour <br /> at 10 psi . Verify line volumes are appropriate for the make and model of the installed leak <br /> detectors . (already completed 1/2/2024) <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464 -0138 1 www. sjgov. org/ehd <br />