Laserfiche WebLink
TEST INSTR1 Cn0NS Socket <br /> POPPET lig FLOAT lw1QVEMEN f <br /> FOR TESTA BLE MODELS ONLY adaptor <br /> DE � <br /> TOOLS NEED hORTESTING, <br /> 1. 114"square drive sn[ensiDn or 318'square drive or. <br /> tension with 318''to 114"socket adbpter. <br /> 2. Torque wrench 1114`or 31W squafe drive ratchet <br /> wrench. ' <br /> 3. Pipe dope. <br /> 4. Flashlight(optional). <br /> Open Poppet Closed Poppet <br /> TEST STEP 1: <br /> Remove spill conUiner cover and fill cap from fill adapt- Test Figum T <br /> er and look down into the tube and make sure no debris Pull on extension a )d <br /> or foreign objects are present_ tf debits or f+vrefgrz ob- <br /> ]rcts are present take appropriate steps before proceed- socket adaptor <br /> inq. Look down into the tube and ensure poppet is <br /> completely protected by titre defiectlon shield. See Test <br /> Figure 1. If poppet is exposed and tank is not Full the <br /> Dvechl l valve should be replaced. A flashlight may help r" <br /> when inspecUngdwtube. <br /> TEST STEP 2; <br /> T <br /> Unthread the socket adaptor assernb#y from the inlet � <br /> tube Using a 114`squaredrive extension and wremh. � <br /> The extension will attach to the socket adaptor. 5ecu re r� <br /> all tools to ensure they don't fall into the tank or valve. <br /> With the extrnsJan still attached pull on the socket <br /> a4aptor and cable assembly and ensure float and pQp- <br /> pct move f f srKtlop property. 1t should only reciutre Y <br /> 164"of movement and less than 5 lbs of force in ander -"'�-�- <br /> to actuate ttw float and poppet, When looking dowry <br /> into the upper tube ensure poppet is visible and moves <br /> into tete flow path isee Test Figure 1 &2)when socket Open <br /> Adaptor n puledar4 resets properly whtwr socket adap- Poppet Closed <br /> tar is released. If poppet clues not actuate freely lake 1 poppet Float moves <br /> appropriate steps to correct. <br /> up <br /> i <br /> TIEST STEP 3: <br /> Apply pipe dope to the socket adaptor threads, pipe <br /> dope should be a non-hardemny gasohne resistant pipe <br /> thread sealeompournd. Make sure poppet and Moat � <br /> have reset properly and are net vislb�e then install sock- <br /> et adaptor Arid torque to 35 ft4bs(42 InAbs)miniMu►n i I <br /> to 5.0!t4bs i50 in-Lbs)maximum. After installing socket i <br /> r <br /> adaptor,to ertsure vapor tlghtness,DPW recomrnerW5 <br /> conducting preswre testing per CARE TP2o1.1 D. Some Tastng4M2 <br /> areas may require pressure testing of overfill valve per <br /> GARB TP201,ID to ensure valve Is vapor tight. If the <br /> drop ttlbe fails pressure testing it may be necessary to <br /> check the seat at the poppet adaptor threads, Reinslail <br /> f�i!cap ir►d�pi�1 LOnlaM�Qf oa v'4�7�r taNAg, <br /> 17 <br />