A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> NASHIR EL DORADO INC 713 N EL DORADO ST, STOCKTON May 30, 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> installed: 1) monitoring panels; 2)in-tank liquid level probes(if used for leak detection); 3)devices monitoring tank <br /> annular spaces or vault;4)devices monitoring product piping; 5)devices monitoring fill piping; 6)devices monitoring <br /> vent piping; 7)devices monitoring vapor recovery piping; 8)devices monitoring vent/transition sumps; 9)devices <br /> monitoring under-dispenser containment; 10)line leak detectors; and 11)devices monitoring any other secondary <br /> containment areas. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is (Minor)Violation. <br /> 7 CA Code of Regulations 2715(a)(1)(B), 2715(a)(3)2010003-Owner/Operator submitted DO form and/or informed the <br /> CUPA of any change(s)within 30 days (TCR 10). <br /> OBSERVATION: New designated operators began conducting inspections and notification was not provided to the <br /> EHD within 30 days of the change.Their names and dates they started conducting inspections are: <br /> -Safuillah Saighani on 09/22/2023 <br /> -Erik Hinojasa on 07/26/2023 <br /> -Ashley Nimmo on 06/30/2023 <br /> REGULATION GUIDANCE:The owner or operator shall submit a"Designated Underground Storage Tank Operator <br /> Identification Form" no later than 30 days after any change in the designated UST operator(s). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is a repeat violation (Class 2) Violation. <br /> 8 CA Code of Regulations 2715(a)(1)(A), 2715(a)(2)2010016-"Underground Storage Tank Statement of Understanding <br /> and Compliance Form"submitted (TCR 10). <br /> OBSERVATION:The Underground Storage Tank Statement of Understanding and Compliance Form has an outdated <br /> business/facility name. <br /> REGULATION GUIDANCE:This form must be uploaded to the California Environmental Reporting System (CERS). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov and upload an up to date Underground Storage Tank Statement of Understanding and <br /> Compliance Form for this facility. <br /> This is(Class 2)Violation. <br /> 10 CA Code of Regulations 2638(c), 2638(d)2030074-Annual Monitoring System Certification Form to the CUPA within <br /> 30 days of completion of the test. <br /> OBSERVATION:Annual monitoring system certification and leak detector testing was performed on 05/30/2023 and a <br /> test report was submitted on 08/16/2023,48 days late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> FA0014678 PR0521604 SCO01 05/30/2024 <br /> EHD Rev.12/06/2021 Page 6 of 11 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />