Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: BREVIA INN & RESTAURANT,1625 E FRENCH CAMP TPKE, STOCKTON 95206 <br /> #9 Ladders and Handrails <br /> OBSERVATIONS: Long handraill near stairs is loose. Tighten before opening. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck.(CBC 31113) Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #13 Cyanuric Acid Concentration <br /> OBSERVATIONS:Cyanuric acid is above 100. Standard range is below 100. Ideal range is between 30-50. <br /> Fix in 2 weeks. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanuric acid concentration between0.0 ppm and 100 ppm.(CCR 65530) <br /> #14 Chemical Water Test Kit <br /> OBSERVATIONS: Recommend getting the DPD Chlorine Kit for accurate readings on chlorine in pool. <br /> CALCODE DESCRIPTION:Pool operator shall maintain a test kit for measuring the disinfectant residual, combined chlorine, pH, and <br /> cyanuric acid(if used)at the pool. Test kit shall be available at all times the pool is in use. Chlorine and bromine test kits shall be DPD <br /> type. Chlorine test kits shall be capable of testing for free and total chlorine, so that combined chlorine concentrations can be determined. <br /> (CCR 65529) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Weir and float valve are missing from skimmer. Provide before opening. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications.(CBC 31368) <br /> #35 Flow Meters <br /> OBSERVATIONS: Flow meter is missing bobble inside to read meter. Clean meter or replace. Provide in 2 weeks. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31258) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 2.6 ppm Temp: ° F <br /> Cyanuric acid: Above 100 ppm pH: 7.4 Combined chlorine: 0 ppm <br /> NOTES <br /> FA0001722 PR0360086 SCO01 08/13/2019 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />