My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 4:25:34 PM
Creation date
6/27/2024 10:46:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0504388
PE
2361 - UST FACILITY
FACILITY_ID
FA0006185
FACILITY_NAME
MARATHON FOOD AND GAS
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1605 S EL DORADO ST STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAID dOAQUIN <br />COUNTY <br />Environmental Health Department <br />EHD Rev. 12/06/2021 <br />FA0006185 PR0504388 SCO01 06/26/2024 <br />Page 5 of 8 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />CP22 - UST FULL Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />STOCKTON FOOD AND GAS <br />1605 S ELDORADO ST STOCKTON <br />June 26 2024 <br />88 <br />CA Code of Regulations <br />2060007 - Primary and secondary containment designed and constructed to an engineering <br />❑ OUT <br />❑ R ❑ COS <br />2631(b&d), 2666(b&e) <br />specification. <br />89 <br />CA Health and Safety <br />2060008 - Enhanced leak detection testing performed before the tank is placed in use <br />❑ OUT <br />❑ R ❑ COS <br />Code 25290.10) <br />90 <br />CA Code of Regulations <br />2060029 - SW piping has been upgraded to continuously monitored DW piping when replacement <br />❑ OUT <br />❑ R D COS <br />2666(b)(2) <br />or repair needed <br />91 <br />CA Health and Safety <br />2010 - Administration/Documentation - General <br />❑ OUT <br />❑ R ❑ COS <br />Code 25291(e) <br />92 <br />2015 - Administrative/Documentation - General Local Ordinance <br />❑ OUT <br />❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />3 <br />CA Code of Regulations 2632(d)(1), 2634(d) 2010013 - Facility has submitted a complete and accurate UST <br />Monitoring Plan.. <br />OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. The monitoring system <br />certification does not list a UDC Leak Sensor Manufacturer or UDC Leak Sensor Model. "Float and Chain" is listed <br />under UDC Panel Manufacturer, but float and chains are not connected to monitoring panels and "Float and Chains" is <br />not a UDC Panel Manufacturer. "Mechanical' is listed under UDC Panel Model # but float and chains are not <br />connected to monitoring panels and "mechanical' is not UDC Model #. <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br />(CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a repeat violation (Class 2) Violation. <br />9 <br />CA Code of Regulations 2638, 26410), 2715(f) 2030002 - Leak detection equipment tested by qualified service <br />technician every 12 months (TCR 9d). <br />OBSERVATION: The annual monitoring system certification and leak detector testing were last performed on <br />7/31/2023 and were due by May 2024. Testing has not been completed and is one month past due. <br />Annual certification is due each May unless conducted sooner than May to reset annual certification dates. The <br />annual certification has been conducted late on 6/30/2021, 6/29/2022, 7/31/2023. <br />REGULATION GUIDANCE: These tests are required once every 12 months. <br />CORRECTIVE ACTION: Immediately schedule these tests and provide 48 hours notification to the EHD. Please be <br />aware that all EHD staff time associated with a follow up inspection will be billed at our current hourly rate ($156). <br />This is a repeat violation (Class 2) Violation. <br />50 <br />CA Code of Regulations 2635, 2637.1, 2665, 2712 2060020 - Spill buckets meet requirements, have been tested as <br />required, and records kept for 36 mths (TCR 9a). <br />OBSERVATION: Annual spill container testing was last performed on 7/31/2023 and was due by May 2024. Testing <br />has not been completed and is one month past due. <br />Annual certification is due each May unless conducted sooner than May to reset annual certification dates. The <br />annual certification has been conducted late on 6/30/2021, 6/29/2022, 7/31/2023. <br />EHD Rev. 12/06/2021 <br />FA0006185 PR0504388 SCO01 06/26/2024 <br />Page 5 of 8 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.