Laserfiche WebLink
Environmental Health Department <br />CP22 - UST FULL Inspection Report <br />Date: <br />July 16, 2024 <br /> Facility Address: <br /> 7272 WEST LN, STOCKTON <br /> Facility Name: <br /> QUIK STOP MARKET #550144 <br /> □ OUT □ R □ COS2060024 - UST system is made of or lined with materials that are compatible with the substance <br />stored. <br />CA Code of Regulations <br />2631.1, 2660(m) <br /> 86 <br /> □ OUT □ R □ COS2060021 - Striker plate installed and positioned correctly.CA Code of Regulations <br />2631(c), 2662(d) <br /> 87 <br /> □ OUT □ R □ COS2060007 - Primary and secondary containment designed and constructed to an engineering <br />specification. <br />CA Code of Regulations <br />2631(b&d), 2666(b&e) <br /> 88 <br /> □ OUT □ R □ COS2060008 - Enhanced leak detection testing performed before the tank is placed in useCA Health and Safety <br />Code 25290.1(j) <br /> 89 <br /> □ OUT □ R □ COS2060029 - SW piping has been upgraded to continuously monitored DW piping when replacement <br />or repair needed <br />CA Code of Regulations <br />2666(b)(2) <br /> 90 <br /> □ OUT □ R □ COS2010 - Administration/Documentation - GeneralCA Health and Safety <br />Code 25291(e) <br /> 91 <br /> □ OUT □ R □ COS2015 - Administrative/Documentation - General Local Ordinance 92 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />CA Code of Regulations 2632(d)(1), 2634(d) 2010013 - Facility has submitted a complete and accurate UST <br />Monitoring Plan.. <br />OBSERVATION: The monitoring plan is not current for the following reason: <br />- The monitoring plan indicates that the "monitoring panel model" is TLS-350 Plus. Yet the "UDC Panel Model #" is <br />indicated as TLS-350. The model found at time of inspection was TLS -350 Plus. <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br />(CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br />This is (Minor) Violation. <br /> 3 <br />CA Code of Regulations 2630(d), 2641(a) 2060015 - Leak detection equipment located so leak is detected at the <br />earliest possible opportunity (TCR 9d). <br />OBSERVATION: The 208 sensor in UDCs 5/6 & 3/4 was not located to detect a leak at the earliest opportunity. <br />- Site formerly had float & chain mechanism and sensor was not placed in cup, which would be the lowest point within <br />the UDC. <br />REGULATION GUIDANCE: All monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. <br />CORRECTIVE ACTION: The service technician placed the sensors within the UDC to detect a leak at the earliest <br />opportunity. <br />This violation was corrected on site <br />This is a repeat violation (Class 2) Violation. <br /> 30 <br />CA Code of Regulations 2635, 2637.1, 2665, 2712 2060020 - Spill buckets meet requirements, have been tested as <br />required, and records kept for 36 mths (TCR 9a). <br />OBSERVATION: Annual spill container testing was previously performed on 7/17/2023, records were not found on site <br />at time of inspection. <br /> 50 <br />FA0002570 PR0231939 SC001 07/16/2024 <br />EHD Rev. 12/06/2021 CP22 - UST FULL OIRPage 5 of 8 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD