Environmental Health Department <br />CP22 - UST FULL Inspection Report <br />Date: <br />July 16, 2024 <br /> Facility Address: <br /> 7272 WEST LN, STOCKTON <br /> Facility Name: <br /> QUIK STOP MARKET #550144 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />REGULATION GUIDANCE: (b) The owner or operator shall maintain the following records on-site, or off-site at a readily <br />accessible location if approved by the local agency, for the specified period. These records shall be made available, <br />upon request within 36 hours, to the local agency or the State Water Board . (1) Monitoring and maintenance records <br />shall be maintained for at least 36 months and include the following: (A) The date and time of all monitoring or <br />sampling; (B) The results of any visual observations; (C) The results of all sample analysis performed in the laboratory <br />or in the field, including laboratory data sheets and analysis used; (D) The logs of all readings of gauges or other <br />monitoring equipment, ground water elevations, or other test results (E) The results of inventory readings and <br />reconciliations; (F) The results of testing; and (G) The results of inspections <br />CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the last <br />three years on site. <br />This is a repeat violation (Class 2) Violation. <br />CA Health and Safety Code 25292.2; CCR 2711(a)(11) 2010007 - Submitted/maintained current Cert of Financial <br />Responsibility/mech of financial assurance (TCR 11). <br />OBSERVATION: Current financial responsibility documents were not found on site. <br />REGULATION GUIDANCE: A copy of current financial responsibility documents are required to be maintained on site . <br />CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br />copy on site. <br />This is a repeat violation (Class 2) Violation. <br /> 53 <br />CA Code of Regulations 2716(a-e) 2030013 - DO inspections completed at least every 30 days and meet all <br />requirements (TCR 12). <br />1.) OBSERVATION: The following were not attached to the designated operator inspection reports: <br />- For the DO report done on 5/6/24, no work order for fuel alarm that occurred on 5/4/2024. <br />REGULATION GUIDANCE: The designated operator visual inspection report shall include: -a copy of documentation <br />demonstrating action taken in response to each compliance issue identified during the previous inspection -a copy of <br />the alarm history since the previous inspection -a copy of documentation demonstrating action taken in response to <br />each alarm since the previous inspection -a list of each alarm since the previous inspection for which there is no <br />documentation of the alarm condition and action taken in response <br />CORRECTIVE ACTION: Ensure all required documents are attached to future designated operator inspection reports. <br />----------------------------------------------------------------------------------------------------------------- <br />2.) OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br />reports. The incorrect and missing information included the following from the inspection reports: <br />- For the DO report on 5/6/24, The owner did not follow up on compliance issue in section 5. <br />REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required testing <br />and maintenance for the UST system have been completed and shall check all required items on the report . <br /> 56 <br />FA0002570 PR0231939 SC001 07/16/2024 <br />EHD Rev. 12/06/2021 CP22 - UST FULL OIRPage 6 of 8 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD