My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4607
>
2300 - Underground Storage Tank Program
>
PR0543692
>
INSTALL_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2025 4:14:30 PM
Creation date
7/18/2024 2:58:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2024
RECORD_ID
PR0543692
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0024830
FACILITY_NAME
ARCO
STREET_NUMBER
4607
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17746013
CURRENT_STATUS
Temp inactive, non-billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4607 S AIRPORT WAY STOCKTON 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
446
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />8. T&L3, detail 5, and T&L4- sump liquid sensor is not shown at the lowest sump point Revised locaƟon EHD: <br />corrected. <br />9. Provide cut sheets for tank sumps and penetraƟons (including electrical) 0and for all UDC <br />and Vent sump penetraƟons, leak detectors, overfill. See aƩached EHD: some cut sheets were provided but some <br />are sƟll missing, like tank sumps, vent sump, all UDC etc. For example, B1000 cut sheet was included for UDCs, <br />however, the UDC part number listed on the plans doesn’t match the provided UDC cut sheet. Please provide cut <br />sheets for all the parts listed on the parts list. <br />10. The provided parts order list shows 2 tanks with 2 compartments each, plans show two compartment and <br />three-compartment tanks, clarify and send in the corrected parts order list Revised parts list tanks , 100, 103 see <br />T&L7 and 7.1 EHD: corrected. <br />11. Provide installer/tester cerƟficaƟons for FE Petro and Flex-ing (Fireflex) When we have a contractor EHD: sƟll <br />need this. <br />12. Provide B-20 compaƟbility informaƟon for all components in contact with B-20 See aƩached sheets. EHD: it’s <br />unclear where this documentaƟon is included, please provide a separate file Ɵtled compaƟbility. <br />13. T&L4, the 6K/24K fill sump on 24K tank chaise penetraƟon is not located at sump wall but is <br />located inside the sump. Also, 6K super tank fill sump has an unlabeled penetraƟon and pipe with <br />what appears to be an electrical connecƟon that terminates at the boƩom of the sump. Revised details EHD: <br />corrected. <br />14. T&L4, details A3 and A4 don’t show chaise lines Added line. EHD: corrected. <br />15. T&L6, Need vacuum communicaƟon details. Added to details EHD: end-of-the-line vacuum communicaƟon <br />provisions couldn’t be located on UDC (T&L6), please point them out. <br />16. Bravo deflector plates are proposed on T&L6, submit bravo cut sheet and installaƟon <br />informaƟon and indicate on plans how they will be installed. Revised to tank manufacturer. EHD: corrected, per <br />plans no deflector plates will be installed, if they will be installed- provide the installaƟon details. <br />17. No chaise piping is shown to 20K diesel fill sump for vent piping run to vent transi Ɵon sump. <br />No chaise piping is shown for this tank on T&L1, update all necessary sheets as well as vacuum zone <br />details, piping length and volumes. See T&L1 and tanks secƟons. EHD: corrected. <br />18. It’s unclear if the master/ satellite piping is VPH-monitored double wall piping. Provide a <br />revision that illustrates, that master/ satellite dispenser piping is double wall and VPH monitored. No monitoring <br />details or vacuum hose connecƟons are shown inside the UDCs x-secƟons for master/satellite dispensers. Update <br />vacuum zones to include pipe lengths and volume details. <br />Revised the details to show this. YES THEY ARE MONITORED EHD: corrected. <br /> <br />19. Not all parts on the list parts and their diamond reference numbers on each respec Ɵve plan <br />sheet match across the plans. For example, part 402 listed mulƟple Ɵmes on T&L2 and appears to <br />point to a Bravo sump penetraƟon, is listed as Fire Flex on the parts list located on page T&L7. To <br />avoid any plan review delays, ensure that all parts lists are accurate on the future submiƩals (pages <br />T&L7 and T&L7.1) and reference accurate parts on all the plan sheets. Done <br />EHD: some issues are sƟll observed with this item. The following list is not all-inclusive and some other issues may <br />exist with the parts list reference system, here are some of the examples. Part number 823 (on the parts list) is <br />listed as 23 each, this part is a combinaƟon of 806 and 815 parts for a complete 823 assembly. However 806 part is <br />also listed separately as 23 each as well as part 815 listed at 23 each- please clarify how many of these will be <br />installed. Part 400 is listed on several plan sheets, but not included on the parts list. Please provide an explanaƟon <br />on part 209 “single port spill plaƞorm” installed on the vent sump. Three parts 218 (vent sumps containment <br />boxes) are listed on the parts list, but only one vent sump is proposed on the plans. Part 229 on sheet T&L3 points <br />to the overfill prevenƟon drop tube, part 229 on parts lists is idenƟfied as a manhole cover. Also, 6 Wayne ovaƟon <br />dispensers are listed on the parts list (parts 300 and 302), however, based on plans 8 dispensers will be installed on <br />the car side. T&L1 lists 6 of part 300. In the interest of expediency and to eliminate future revision requests, please <br />review all the parts on the parts list and their references on all plan sheets and correct all the discrepancies, not <br />only those listed above.