Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2450
>
2800 - Aboveground Petroleum Storage Program
>
PR0529613
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 2:54:19 PM
Creation date
8/8/2024 4:02:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0529613
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0009494
FACILITY_NAME
MANTECA WQCF
STREET_NUMBER
2450
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337-9641
APN
24130050
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2450 W YOSEMITE AVE MANTECA 95337-9641
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - AST Non-Qualified Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MANTECA WQCF 2450 W YOSEMITE AVE MANTECA Jul 31 2024 <br /> 86 4045-Release/Leaks/Spills-General Local Ordinance ❑OUT ❑R ❑COS <br /> 87 See below 4050-Abandonment/Illegal Disposal/Unauthorized Treatment-General ❑OUT ❑R ❑COS <br /> 88 4055-Abandonment/Illegal Disposal/Unauthorized Treatment-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS Il,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 2 Code of Fed Regulations 112.3, 112.6 4010057-SPCC plan has been prepared that meets all applicable <br /> requirements. <br /> OBSERVATION:The facility failed to prepare an SPCC Plan that meets all applicable requirements. <br /> -The SPCC Plan does not address 112.8(d)(5) <br /> REGULATION GUIDANCE:25270.4.5 (a)Except as provided in subdivision (b),the owner or operator of a storage tank <br /> at a tank facility subject to this chapter shall prepare a spill prevention control and countermeasure plan applying good <br /> engineering practices to prevent petroleum releases using the same format required by Part 112 (commencing with <br /> Section 112.1)of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations, including owners and <br /> operators of tank facilities not subject to the general provisions in Section 112.1 of those regulations.An owner or <br /> operator specified in this subdivision shall conduct periodic inspections of the storage tank to ensure compliance with <br /> Part 112 (commencing with Section 112.1)of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. <br /> In implementing the spill prevention control and countermeasure plan, an owner or operator specified in this subdivision <br /> shall fully comply with the latest version of the regulations contained in Part 112 (commencing with Section 112.1)of <br /> Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. 112.3:The owner or operator or an onshore <br /> or offshore facility subject to this section must prepare in writing and implement a Spill Prevention Control and <br /> Countermeasure Plan in accordance with§ 112.7 and any other applicable section of this part. <br /> CORRECTIVE ACTION: Ensure that facility's SPCC plan meets all applicable requirements. Submit proof of correction <br /> to the EHD <br /> This is (Minor)Violation. <br /> 3 Code of Fed Regulations 112.3 4030038-SPCC has been implemented. <br /> OBSERVATION:The Spill Prevention, Control, and Countermeasure(SPCC)Plan was not implemented, as required <br /> (applicable sections of the SPCC Plan are included below). <br /> 4.4, 5.2, 6.5: Spill kit observed empty in 55-gallon drum storage area without equipment listed in the SPCC plan <br /> 4.4, 5.1, 6.5: Spill kits were not found in proximity of all ASTs. The only spill kit near ASTs was located was located in <br /> the 55-gallon drum storage area. <br /> 4.1,4.4.1, 5.2.2: A 55-gallon drum labeled Rotella T Oil 40 was observed located directly on the floor, not located on a <br /> spill pallet as specified in the plan. <br /> 5.2.8: Monthly testing of liquid-level gauges on applicable ASTs <br /> REGULATION GUIDANCE: 112.3: The owner or operator or an onshore or offshore facility subject to this section must <br /> prepare in writing and implement a Spill Prevention Control and Countermeasure Plan (hereafter"SPCC Plan"or <br /> "Plan")," in accordance with § 112.7 and any other applicable section. 25270.4.5.(a):An owner or operator shall <br /> conduct periodic inspections of the storage tank to ensure compliance with Part 112 (commencing with Section 112.1) <br /> of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. In implementing the spill prevention control <br /> and countermeasure plan, an owner or operator shall fully comply with the latest version of the regulations contained in <br /> Part 112 (commencing with Section 112.1)of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. <br /> FA0009494 PR0529613 SCO01 07/31/2024 <br /> EHD Rev.12/06/2021 Page 5 of 8 CP22-AST Non-Qualified OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.