Laserfiche WebLink
s <br />CONCRETE PAD <br />18' SQUARE <br />IRON FERRULE WITH <br />BRASS COUNTERSUNK <br />CLEANOUT PLUG <br />NO. 3 REINFORCE 5AR5.TWO EACH WAY --' <br />CAST IRON SOIL PIPE P15ER <br />FINISH <br />GRADE <br />NOTE: <br />CONCRETE PAD TO BE FLUSH <br />WITH FINISH GRADE IN PAVED AREAS CAST IRON 1/5BEND <br />WYE BRANCH SAME MATERIAL AS LINE <br />1/8 BEND IF CLEANOUT <br />eOCCURS AT END Of LINE <br />e FLOW <br />CLEANOUT TO GRADE DETAIL <br />SCALE: NONE <br />FINISHED FLOOR <br />WATERPROOF MEMBRANE <br />FLASH LED INTO <br />CLAMPING COLLAR <br />NOTE: ALL FLOOR DRAINS MUST HAVE TRAP PRIMER. <br />FLOOR DRAIN DETAIL <br />SCALE: NONE <br />eFINISHED FLOOR <br />CLAMPING COLLAR <br />112" TRAP PRIMER <br />9TR <br />NOTE: TRAP PRIMER IF RE QUIP, <br />/2" TRAP PRIMER <br />1 <br />FLOOR SINK DETAIL <br />SCALE: NONE <br />FOR EXPANSION. <br />LEAD FLASHING, TYPICAL <br />FILL VOID WITH INSULATION <br />MATERIAL, TYPICAL — <br />ROOF STRUCTURE <br />VENT THRU ROOF DETAIL <br />SCALE: NONE <br />2" MIN. <br />COUNTER FLASHING AND <br />SEALANT FOR VENTS 2N" <br />AND SMALLER <br />9" MIN <br />LAP ROOFING OVER FLASHING <br />WITH ROOFING SEALANT <br />BUILT—UP ROOFING <br />HOT WATER DEMAND CALCULATION <br />BTUM <br />CFH <br />FIXTURE SERVED <br />NO. UNITS <br />GPH <br />TOTAL GPH <br />Utensil/3-Compartment Sinks <br />I <br />X 42 <br />= 42 <br />Mop Sinks <br />I <br />X 15 <br />= 15 <br />Lavatory <br />T <br />X 5 <br />= 5 <br />Dump Sinks <br />0 <br />X 6 <br />= 0 <br />Handwash Sinks <br />2 <br />X 5 <br />= 10 <br />Food Preparation Sinks <br />I <br />X 5 <br />= 5 <br />Clothes Washer 9 and 12 Ib washers <br />01 <br />X 1 <br />0 <br />Automatic Utensil Washing Machine" <br />01 <br />X 1 68 <br />= 0 <br />OUTDOOR • <br />= 77 <br />TOTAL GPH (gallons per hour) <br />Sizing Requirements for Storage Water Heaters (Not Instantaneous Water Heaters): <br />Facilities with multi -service eatin utensils heavyuse serum 3 meals a da 100%a GPH required <br />Fac <br />tieswithmulti-service eating utensils moderated use 90%GPH required <br />Facilities with single service eating utensils or don't use utensils at all 80%a GPH required <br />TntnI r:PP mmirori- 77 X 80%=GPH required = 62 G11 <br />Computing the BTU input (Gas Water Heaters): <br />GPH required x 601 Rise x 11 = 40656 BTU input of water heater <br />GPH required x 800 Rise x 11 = 54208 BTU input of water heater <br />(if a 1800 rinse automatic utensil washing machine with a 400 rise booster is used) <br />GAS PIPE SIZING CALCULATION <br />BTUM <br />CFH <br />ao <br />CC LO to <br />LENGTH <br />(Fr) <br />PIPE SIZE <br />(IN) <br />BRANCH <br />(IN) <br />DEMAND: WATER HEATER <br />TOTAL <br />70„000 <br />70 <br />70 <br />170 <br />314” <br />314" <br />70,000 <br />70 <br />DEVELOPED LENGTH <br />170 FT <br />WASTE <br />PIPE SIZE AS PER CPC TABLE 1216.21) <br />3/4" <br />i <br />IP - <br />(N)3/4• <br />(N) FS <br />G 1ti6 <br />a <br />N FC Z <br />?s, <br />z GAS <br />METER <br />(N)TOTAL: 70 kBTU <br />WATER TOTAL LENGTH: 170 FT <br />�HEATE <br />70 kBTU <br />GAS ISOMETRIC <br />NO SCALE <br />V2"4 <br />'--(N) 2" vfR <br />FD (N)3"4 <br />* PEX, ABS DWV, OR PVC PLASTIC IS ACCEPTABLE IF ALLOWED BY THE AUTHORITY HAVING JURISDICTION. <br />CONTRACTOR TO PROVIDE BID ALTERNATE AND APPROVAL LETTER TO OWNER FOR CONSIDERATION. <br />(N) 3/4" GAS LINE <br />ITO EXISTING GAS <br />METER (TOTAL 170') <br />Z, 70 KBTU <br />"LAV AND WC <br />PLUMBING IN <br />THE RESTROOM <br />ARE EXISTING <br />I 1 <br />SEWER & GAS PLAN <br />SCALE: 1/4" = 1' <br />— - — - COLD WATER <br />— - - — HOT WATER <br />vv <br />WATER PLAN <br />SCALE: 1/4" = 1' <br />—'t.AV AND WC <br />PLUMBING IN <br />THE RESTROOM <br />ARE EXISTING <br />(N)3/4' 0 i V <br />O <br />MATERIAL SPECIFICATIONS <br />a o oM <br />ao <br />CC LO to <br />SERVICES <br />o'er '0\ 4, <br />Q,° <br />MARKS <br />COLD <br />WATER <br />ABOVE GROUND <br />• <br />* <br />* SEE NOTE <br />BELOW GROUND • <br />HOT <br />WATER <br />ABOVE GROUND <br />• <br />* <br />* SEE NOTE <br />BELOW GROUND • <br />WASTE <br />ABOVE GROUND <br />d <br />o ac Ea <br />• <br />* SEE NOTE <br />BELOW GROUND • <br />VENT <br />ABOVE GROUND <br />�L o c C.`..� N <br />a d <br />• <br />* SEE NOTE <br />BELOW GROUND • <br />NATURAL <br />GAS <br />INDOOR <br />• <br />PAINTED WITH RUST <br />INHIBITING PAINT <br />OUTDOOR • <br />INDIRECT <br />WASTE <br />INDOOR <br />• <br />OUTDOOR • <br />STORM <br />DRAIN <br />ABOVE GROUND <br />• <br />Sad: <br />ESS1 <br />K, WHAM a <br />BELOW GROUND • <br />* PEX, ABS DWV, OR PVC PLASTIC IS ACCEPTABLE IF ALLOWED BY THE AUTHORITY HAVING JURISDICTION. <br />CONTRACTOR TO PROVIDE BID ALTERNATE AND APPROVAL LETTER TO OWNER FOR CONSIDERATION. <br />(N) 3/4" GAS LINE <br />ITO EXISTING GAS <br />METER (TOTAL 170') <br />Z, 70 KBTU <br />"LAV AND WC <br />PLUMBING IN <br />THE RESTROOM <br />ARE EXISTING <br />I 1 <br />SEWER & GAS PLAN <br />SCALE: 1/4" = 1' <br />— - — - COLD WATER <br />— - - — HOT WATER <br />vv <br />WATER PLAN <br />SCALE: 1/4" = 1' <br />—'t.AV AND WC <br />PLUMBING IN <br />THE RESTROOM <br />ARE EXISTING <br />(N)3/4' 0 i V <br />O <br />U <br />a o oM <br />ao <br />CC LO to <br />~to <br />Q N U <br />atd <br />W U tU <br />> <br />CD <br />W O <br />0) <br />Wa mss_ D <br />Q° 00W wF— <br />4 <br />Y <br />C N O O U <br />O 3 L L C <br />w"0 cc N G y O <br />0 0._ 3 <br />O U C a <br />.2 0 <br />o E E d <br />U <br />L N <br />N- N <br />Q_ n.2 °c==m <br />W D OjE Op.,L `0 <br />- a�6LL^ '3 <br />o vi <br />d <br />o ac Ea <br />N 0=, y O C O N <br />01 a) a T a'- 6 cc C V <br />C L N N �0 U O O N <br />• L m 0' rU =0- <br />O O a L C a U a LD <br />�.., J <br />O <br />V'O <br />CO <br />dy.0 O C N <br />U� <br />z � �� o o c w E.2•S <br />�L o c C.`..� N <br />a d <br />O <br />N <br />OW <br />L O1. 7 L N N L p <br />L N i O w - <br />N O 2 N I N N..L, d o h < <br />N 3 w K E 3 a 0 0 0 <br />REVISIONS/DATE <br />Sad: <br />ESS1 <br />K, WHAM a <br />h <br />c� <br />NO. 63640 <br />Exp. 09/30/2024 <br />sT9 �7V P <br />C <br />a Its <br />MOD <br />a <br />� Q � <br />U� Gig <br />Drawn By A. DANG <br />Checked By <br />Bate 1-12-23 <br />scale <br />Job Na. AS NOTED <br />SEWER <br />PLAN <br />Drawing No. <br />e -I <br />of Sheets <br />