My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 9:28:53 PM
Creation date
1/14/2025 9:59:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231656
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
85 E LOUISE AVE LATHROP 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( n J o Q I Environmental Health Department <br /> COUNTY <br /> SCOPE OF WORK REQUIRED PERMIT TYPE <br /> DISPENSERS <br /> Installation of additional dispensers or relocation of existing dispensers (3) UST Retrofit - Full Permit <br /> Dispenser replacement with conversion frame (4) UST Retrofit - Minor Plan Check <br /> Dispenser replacement due to structural damage (e.g. vehicular incident) (4) UST Retrofit - Minor Plan Check <br /> Dispenser replacement with no vehicular damage and no conversion frames (5) UST Retrofit - No Fee Permit <br /> Conversion frame installation or replacement (4) UST Retrofit - Minor Plan Check <br /> Deflector plate installation or replacement (5) UST Retrofit - No Fee Permit <br /> Dispenser repair or reprogramming (6) No permit needed <br /> Filter replacement (6) No permit needed <br /> FLOATS AND CHAINS <br /> Float-and-chain repair or replacement - "like for like" (5) UST Retrofit - No Fee Permit <br /> Shear valve repair or replacement when connected to a float-and-chain device (5) UST Retrofit - No Fee Permit <br /> Shear valve repair or replacement when NOT connected to a float-and-chain device (6) No permit needed <br /> Chain tightening or adjustment (6) No permit needed <br /> Removal of floats-and-chains (switching to sensors) (3) UST Retrofit - Full Permit <br /> Filling float-and-chain cups/holes or removal of barriers when floats were previously (4) UST Retrofit - Minor Plan Check <br /> removed under permit <br /> SPILL CONTAINERS <br /> Direct bury spill container replacement (3) UST Retrofit - Full Permit <br /> Direct bury double wall spill container "primary bucket" replacement— no breaking of (3) UST Retrofit - Full Permit <br /> concrete <br /> Spill container in a tank top sump - "like for like" (5) UST Retrofit - No Fee Permit <br /> Spill container in a tank top sump - not "like for like" (4) UST Retrofit - Minor Plan Check <br /> Spill container drain valve replacement (6) No permit needed <br /> Vapor bucket replacement (6) No permit needed <br /> Equipment replacement or modification inside a spill container that reduces capacity (5) UST Retrofit - No Fee Permit <br /> Riser piping repair or replacement in a sump on tanks installed prior to 7/1/03 (6) No permit needed <br /> OVERFILL PREVENTION <br /> Overfill prevention equipment installation, repair, or replacement (3) UST Retrofit - Full Permit <br /> Overfill shut-off valve (flapper) installation, repair, or replacement (3) UST Retrofit - Full Permit <br /> Tank probe installation or replacement when used for overfill prevention (3) UST Retrofit - Full Permit <br /> Tank probe replacement when not used for overfill prevention (6) No permit needed <br /> Float replacement on tank probe when probe is used for overfill prevention (4) UST Retrofit - Minor Plan Check <br /> Annunciator/light bulb replacement for external audible/visual for overfill prevention (5) UST Retrofit - No Fee Permit <br /> LID REPAIR/REPLACEMENT <br /> Manway replacement which requires concrete removal/replacement (5) UST Retrofit - No Fee Permit <br /> Manway lid replacement with no concrete removal/replacement (6) No permit needed <br /> Sump lid repair or replacement for tanks installed prior to 7/1/03 (6) No permit needed <br /> Sump lid repair or replacement for tanks installed on or after 7/1/03 (4) UST Retrofit - Minor Plan Check <br /> Water & vapor intrusion component replacement (shroud boots, lid gaskets, etc.) for (5) UST Retrofit - No Fee Permit <br /> tanks installed on or after 7/1/03 <br /> RELAY SWITCH/CONTROLLER <br /> Relay switch repair or replacement, if used for positive shutdown (5) UST Retrofit - No Fee Permit <br /> Relay switch repair or replacement, if not used for positive shutdown (6) No permit needed <br /> Replacement/installation of MagVFC variable speed controllers at sites with PLLDs (6) No permit needed <br /> OTHER <br /> Turbine replacement (6) No permit needed <br /> test leak detectorforfunctionality after work is done <br /> Breaking concrete over tank systems, including over piping (5) UST Retrofit - No Fee Permit <br /> Air pollution control equipment installation, repair, or replacement - contact the San (6) No permit needed <br /> Joaquin Valley Air Pollution Control District <br /> REVISED 8/1/2024 <br /> 3of3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.