My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 9:28:53 PM
Creation date
1/14/2025 9:59:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231656
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
85 E LOUISE AVE LATHROP 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA N J o A Q U I N Environmental Health Department <br /> COUNTY <br /> SCOPE OF WORK REQUIRED PERMIT TYPE <br /> TANKS <br /> New installation (1) UST Installation Permit <br /> Removal (2) UST Closure Permit <br /> Closure in place (2) UST Closure Permit <br /> Temporary closure (2) UST Closure Permit <br /> Tank lining or tank repair (3) UST Retrofit - Full Permit <br /> Change of product stored in tank with piping addition or disconnection (3) UST Retrofit - Full Permit <br /> Notify ust@sjgov.org at least 30 days before change <br /> Change of product stored in tank from one type to another (gasoline, diesel, E85, B20, (4) UST Retrofit - Minor Plan Check <br /> etc.) when no piping addition or disconnection is needed Notify ust@sjgov.org at least 30 days before change <br /> Change of product stored in tank when both types are gasoline (e.g. 89 to 87) when no (5) UST Retrofit - No Fee Permit <br /> piping addition or disconnection is needed Notify ust@sjgov.orgatleast30 days before change <br /> Cathodic protection repair, replacement, modification, or installation (3) UST Retrofit - Full Permit <br /> PRIMARY & SECONDARY CONTAINMENT <br /> Regulated buried primary piping repair, replacement, relocation, or installation (3) UST Retrofit - Full Permit <br /> downstream of the shear valve, including replacement of buried flex connectors <br /> Primary or secondary piping repair or replacement fully inside a sump (4) UST Retrofit - Minor Plan Check <br /> Flex connector replacement fully inside a sump (4) UST Retrofit - Minor Plan Check <br /> Primary piping repair or replacement above the shear valve (6) No permit needed <br /> Vent or vapor recovery piping repair or replacement for tanks installed prior to 7/1/03 (6) No permit needed <br /> Secondary containment repairs, including piping, penetrations, sumps, and tanks (3) UST Retrofit - Full Permit <br /> Penetration boot replacement requiring disconnection of piping, breaking of concrete, or (3) UST Retrofit - Full Permit <br /> sump modification <br /> Split repair penetration installations which do not require concrete breaking, piping (4) UST Retrofit - Minor Plan Check <br /> disconnection, or sump/piping modifications <br /> Test boot repair or installation which does not require piping disconnection (6) No permit needed <br /> Vacuum or brine test port installation or replacement (3) UST Retrofit - Full Permit <br /> Brine addition when done by a properly certified technician (6) No permit needed <br /> Brine replacement due to contamination or mixing of brine types (3) UST Retrofit— Full Permit <br /> UST expansion or tank top upgrade (3) UST Retrofit - Full Permit <br /> MONITORING SYSTEM <br /> Sensor replacement - not "like for like" (4) UST Retrofit - Minor Plan Check <br /> Sensor replacement - "like for like" (5) UST Retrofit - No Fee Permit <br /> Sensor disconnection and reinstallation of same sensor (6) No permit needed <br /> 2 to 1 sensor input box replacement (5) UST Retrofit - No Fee Permit <br /> Leak detector replacement - not "like for like" (4) UST Retrofit - Minor Plan Check <br /> Leak detector replacement - "like for like" (5) UST Retrofit - No Fee Permit <br /> Leak detector copper vent tube replacement (6) No permit needed <br /> Cold start of monitoring panel (5) UST Retrofit - No Fee Permit <br /> Monitoring panel software upgrade with no cold start needed (6) No permit needed <br /> Monitoring panel module replacement —when connected to leak detection sensors (5) UST Retrofit - No Fee Permit <br /> Monitoring panel replacement - "like for like" with existing sensors (5) UST Retrofit - No Fee Permit <br /> Monitoring panel replacement - not "like for like" with existing sensors (4) UST Retrofit - Minor Plan Check <br /> Monitoring panel replacement - not "like for like" with new sensors (3) UST Retrofit - Full Permit <br /> Monitoring panel light bulb or keypad replacement (6) No permit needed <br /> Hangar/sleeve installation for positioning of a sensor- not attached to sump wall, (6) No permit needed <br /> opening for liquid entry at the bottom <br /> Hangar/sleeve installation for positioning of a sensor— glued to sump wall (4) UST Retrofit - Minor Plan Check <br /> Hangar/sleeve installation for positioning of a sensor - with holes drilled in sump wall (3) UST Retrofit - Full Permit <br /> Vacuum or brine sensor communication repair, when no secondary containment (4) UST Retrofit - Minor Plan Check <br /> modification or repair is needed <br /> Epoxy pack replacement for existing wire connections (6) No permit needed <br /> Electrical junction box replacement, repair, or installation (6) No permit needed <br /> Emergency Stop (E-stop) replacement— contact the local fire agency (6) No permit needed <br /> 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.