Laserfiche WebLink
SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO 06080 185 E LOUISE AVE LATHROP December 16 2025 <br /> 76 CCR 2630, 2632, 2643, 2030015-Facility demonstrated that methods used to monitor the UST system ❑ OUT ❑ R ❑ COS <br /> 2644.1 complies with standards (TCR 9d) <br /> 77 CCR 2712(f) 2030073-Facility has corrected cited violations within 30 days of receiving report ❑ OUT ❑ R ❑ COS <br /> 78 CCR 2650(e), 2652 2030077-Owner/Operator notified/prepared report upon discovery of unauthorized ❑ OUT ❑ R ❑ COS <br /> release (TCR 9d) <br /> 79 CCR 2717.1(g) 2030045-Red Tag information is legible and has not been removed or tampered ❑ OUT ❑ R ❑COS <br /> with <br /> 80 CCR 2717.1(f); HSC 2030044-Facility did not deposit/allow deposit of petroleum or a hazardous ❑OUT ❑ R ❑COS <br /> 25292.3(c) substance into a red tagged UST <br /> 81 HSC 25292.3(c)(1)(C) 2030079-Facility did not dispense petroleum or a hazardous substance from a ❑OUT ❑ R ❑ COS <br /> UST that has been red tagged <br /> 82 CCR 2670(b)(e)(f), 2671 2030063-Facility is in compliance with temporary closure requirements ❑ OUT ❑ R ❑COS <br /> 83 HSC 25298(c); CCR 2030038-UST system properly closed and complies with permanent closure ❑ OUT ❑ R ❑COS <br /> 2670,2672 requirements <br /> 84 HSC 25392.4(d), 25292.5 2030066-Repaired/retested any leaks found when ELD testing a UST within 1,000 ❑ OUT ❑ R ❑ COS <br /> (c) feet of a public water well <br /> 85 CCR 2631(a); HSC 2060027-Tank system primary containment is constructed, operated, and ❑ OUT ■ R ■ COS <br /> 25290.1(c) maintained product-tight. <br /> 86 CCR 2631.1, 2660(m) 2060024-UST system is made of or lined with materials that are compatible with ❑ OUT ❑ R ❑ COS <br /> the substance stored. <br /> 87 CCR 2631(c), 2662(d) 2060021 -Striker plate installed and positioned correctly. ❑ OUT ❑ R ❑ COS <br /> 88 CCR 2631(b&d), 2666 2060007-Primary and secondary containment designed and constructed to an ❑ OUT ❑ R ❑ COS <br /> (b&e) engineering specification. <br /> 89 HSC 25290.1 Q) 2060008-Enhanced leak detection testing performed before the tank is placed in ❑ OUT ❑ R ❑ COS <br /> use <br /> 90 CCR 2666(b)(2) 2060029-SW piping has been upgraded to continuously monitored DW piping ❑ OUT ❑ R ❑COS <br /> when replacement or repair needed <br /> 91 HSC 25291(e) 2010-Administration/Documentation-General ❑ OUT ❑ R ❑ COS <br /> 92 - 2015-Administrative/Documentation-General Local Ordinance ❑ OUT ❑ R ❑ COS <br /> 93 CCR 23 CCR 16 2711(d); 2030021-Facility has a valid Permit to Operate from the CUPA ❑ OUT ❑ R ❑ COS <br /> HSC 6.7 25284 <br /> 94 CCR 23 CCR 16 2711; 2010010-Complete and accurate UST Operating Permit Application has been ❑ OUT ❑ R ❑ COS <br /> HSC 6.7 25284, 25286 submitted. <br /> 95 CCR 23 CCR 16 2632(d) 2010013-Facility has submitted a complete and accurate UST Monitoring Plan. ❑ OUT ❑ R ❑ COS <br /> (1), 2634(d), 2641(h) <br /> 96 CCR 23 CCR 16 2632(d) 2010014-Facility has submitted a complete and accurate UST Response Plan. ❑ OUT ❑ R ❑ COS <br /> (2), 2634(e), 2641(h) <br /> 97 CCR 23 CCR 16 2632(d) 2030041-A current facility plot plan is maintained and has been submitted ❑OUT ❑ R ❑COS <br /> (1)(C), 2641(h) <br /> 98 HSC 6.7 25299(a)(8) 2010006-Owner/Operator has not made false statements, certifications, or ❑ OUT ❑ R ❑ COS <br /> and/or 25299(b)(7) representations on documents <br /> 99 CCR 23 CCR 16 2715(a) 2010003-Owner/Operator submitted DO form and/or informed the CUPA of any ❑ OUT ❑ R ❑ COS <br /> (1)(B), 2715(a)(3) change(s)within 30 days(TCR 10) <br /> 100 CCR 23 CCR 16 2715(a) 2010016-?Underground Storage Tank Statement of Understanding and ❑ OUT ❑ R ❑ COS <br /> (1)(A), 2715(a)(2) Compliance Form?submitted (TCR 10) <br /> 101 CCR 23 CCR 16 2638(a) 2030002-Leak detection equipment tested by qualified service technician every 12 ❑ OUT ❑ R ❑ COS <br /> &(b), 26410), 2715(f) months (TCR 9d) <br /> 102 CCR 23 CCR 16 2638(c), 2030074-Annual Monitoring System Certification Form to the CUPA within 30 days ❑ OUT ❑ R ❑COS <br /> 2638(d) of completion of the test <br /> 103 CCR 23 CCR 16 2637(a), 2030048-Sec containment testing conducted per requirements&records kept for ❑ OUT ❑ R ❑COS <br /> 2637(b), 2637(c), 2637 36 mths(TCR 9d) <br /> (d), 2712(b)(1)(F) <br /> EHD-CUPA Inspection Report IS03 Page 4 of 9 FA0003635 PR0231656 4589472 12/16/2025 <br /> CP22-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />