My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 9:28:53 PM
Creation date
1/14/2025 9:59:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231656
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
85 E LOUISE AVE LATHROP 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO 06080 185 E LOUISE AVE LATHROP December 16 2025 <br /> 104 CCR 23 CCR 16 2637(e), 2010009-Secondary containment test results submitted to the CUPA within 30 days ❑OUT ❑ R ❑ COS <br /> (f) after the test. <br /> 105 CCR 23 CCR 16 2637.1 2010017-Spill bucket testing results submitted to the UPA within 30 days of testing ❑ OUT ❑ R ❑ COS <br /> (d), 2637.1(e) <br /> 106 CCR 23 CCR 16 2637.2 2010018-Overfill prevention equipment inspection report form submitted to the ❑ OUT ❑ R ❑ COS <br /> (d), 2637.2(e), 2665(a), UPA within 30 days <br /> 2665(b) <br /> 107 CCR 23 CCR 16 2636(f) 2030042-Line integrity test completed on DW press piping every 12 mths if no fail ❑ OUT ❑ R ❑ COS <br /> (3), 2643(c)(3), 2661(f); safe/+shutdown(TCR 9d) <br /> HSC 6.7 25291(f), <br /> 25290.2(g), 25292(e) <br /> 108 CCR 23 CCR 16 2643(d), 2030050-0.1 gph piping test conducted on SW suction systems every 36 mths and ❑ OUT ❑ R ❑COS <br /> 2661(f) after piping repair(TCR 9d) <br /> 109 CCR 23 CCR 16 2643(e), 2030051-0.1 gph piping test conducted on SW gravity systems every 24 mths and ❑ OUT ❑ R ❑COS <br /> 2661(f) after piping repair(TCR 9d) <br /> 110 CCR 23 CCR 16 2663, 2030029-Tank lining inspected Min 10 years of lining, every 5 years after, cert ❑ OUT ❑ R ❑COS <br /> 2712(b)(6) submitted to CUPA(TCR 9c) <br /> 111 CCR 23 CCR 16 2644.1 2010005-ELD testing results sent to the board and the CUPA within 60 days of ❑ OUT ❑ R ❑COS <br /> (a)(5) completion of the test <br /> 112 CCR 23 CCR 16 2646.1 2030056-SIR Report submitted to the CUPA every 12 months ❑ OUT ❑ R ❑ COS <br /> G) <br /> 113 CCR 23 CCR 16 2637(g), 2030064-CUPA was notified within 48 hours prior to testing ❑ OUT ❑ R ❑COS <br /> 2637.1(f), 2637.2(f), 2638 <br /> (e), 2643(g), 2644.1(a)(4) <br /> 114 CCR 23 CCR 16 2640(e), 2030068-Initial or triennial ELD testing conducted on UST system 1000?of public ❑ OUT ❑ R ❑ COS <br /> 2644.1; HSC 6.7 25292.4 well <br /> (a), 25292.5(a) <br /> 115 CCR 23 CCR 16 2635(e) 2060001-As-built plans for new installations and/or with the permit application have ❑ OUT ❑ R ❑COS <br /> (8) been submitted <br /> 116 CCR 23 CCR 16 2632(c) 2030003-Leak detection system maintains continuous monitoring that activates an ❑ OUT ❑ R ❑ COS <br /> (2)(B), 2634(d)(1)(A), audible and visual alarm <br /> 2636(f)(1) <br /> 117 CCR 23 CCR 16 2631(g), 2030016-Annular space of USTs are continuously monitored with an audible and ❑ OUT ❑ R ❑COS <br /> 2632(c)(2)(A)&(B) visual alarm system (TCR 9d) <br /> 118 CCR 23 CCR 16 2636(f) 2030017-Piping out of UDC is fail-safe/shut down, UDC leak shuts off pump/flow, ❑ OUT ❑ R ❑COS <br /> (4) or tightness test(TCR 9d) <br /> 119 CCR 23 CCR 16 2636(f) 2030018-DW press piping is monitored with an audible/visual alarm or stops flow at ❑OUT ❑ R ❑COS <br /> (1), 2666(b)(2) UDC(TCR 9d) <br /> 120 CCR 23 CCR 16 2638(a), 2030043-Leak detection equipment properly installed,calibrated, operated, and ❑OUT ❑ R ❑COS <br /> 26410) maintained (TCR 9d) <br /> 121 CCR 23 CCR 16 2631; 2060005-UST system constructed with a mon system capable of detecting entry ❑ OUT ❑ R ❑ COS <br /> HSC 6.7 25291(b) into secondary containment <br /> 122 CCR 23 CCR 16 2630(d), 2060015-Leak detection equipment located so leak is detected at the earliest ❑ OUT ❑ R ❑ COS <br /> 2641(a) possible opportunity(TCR 9d) <br /> 123 HSC 6.7 25299(a)(9) 2030062-Leak detection equipment has not been tampered with or disabled (TCR ❑ OUT ❑ R ❑ COS <br /> 9d) <br /> 124 CCR 23 CCR 16 2636(f), 2030075-E tank system LLD detects 3 gph leak&restricts/shuts off flow or ❑ OUT ❑ R ❑ COS <br /> 2666(c), 2666(f) activates and/vis alarm (TCR 9d) <br /> 125 HSC 6.7 25290.2(d) 2060022-System has a mon system capable of detecting entry of haz sub or water ❑ OUT ❑ R ❑COS <br /> into secondary containment <br /> 126 CCR 23 CCR 16 2638(f), 2030034-Tag/sticker on affixed monitoring equipment being certified, repaired,or ❑ OUT ❑ R ❑ COS <br /> 2641 Q) replaced <br /> 127 HSC 6.7 25290.1(e) 2030065-Interstitial space of the UST is under constant VPH monitoring (TCR 9d) ❑ OUT ❑ R ❑ COS <br /> 128 HSC 6.7 25290.1(d) 2060023-System has a mon system that can detect entry of haz sub liquid/vapor, ❑ OUT ❑ R ❑ COS <br /> or water into sec contain <br /> EHD-CUPA Inspection Report IS03 Page 5 of 9 FA0003635 PR0231656 4589472 12/16/2025 <br /> CP22-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.