Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> CQUNT AMENDED <br /> 1/9/2025 <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TULARE FARMS LLLP 2771 E FRENCH CAMP RD MANTECA January 06 2025 <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 7 CA Code of Regulations 2715(a)(1)(B), 2715(a)(3)2010003-Owner/Operator submitted DO form and/or informed the <br /> CUPA of any change(s)within 30 days(TCR 10). <br /> OBSERVATION:A new designated operator, Saifiullah Saighani, began conducting inspections on April 30 2024 and <br /> notification was not provided to the EHD within 30 days of the change. <br /> REGULATION GUIDANCE:The owner or operator shall submit a"Designated Underground Storage Tank Operator <br /> Identification Form" no later than 30 days after any change in the designated UST operator(s). <br /> CORRECTIVE ACTION: This was corrected after the inspection before the final inspection was written. The updated <br /> D.O form was uploaded into CERS January 8, 2025. <br /> This is(Minor)Violation. <br /> 10 CA Code of Regulations 2638(c), 2638(d)2030074-Annual Monitoring System Certification Form to the CUPA within <br /> 30 days of completion of the test. <br /> OBSERVATION:Annual monitoring system certification and leak detector testing was performed on January 19, 2024 <br /> and a test report was submitted on February 23, 2024, 5 days late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed <br /> in a timely manner. <br /> This is a repeat violation (Class 2) Violation. <br /> 12 CA Code of Regulations 2637(e), 2637(f)2010009- Secondary containment test results submitted to the CUPA within <br /> 30 days after the test.. <br /> OBSERVATION: Secondary containment testing was performed on December 15, 2023 and a test report was <br /> submitted on January 23, 2024, 9 days late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed <br /> in a timely manner. <br /> This is a repeat violation (Class 2) Violation. <br /> 13 CA Code of Regulations 2637.1(d), 2637.1(e)2010017- Spill bucket testing results submitted to the UPA within 30 <br /> days of testing. <br /> OBSERVATION:Annual spill container testing was performed on January 19, 2024 and a test report was submitted on <br /> FA0003508 PR0234251 SCO01 01/06/2025 <br /> EHD Rev.12/06/2021 Page 5 of 7 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />