My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 8:39:33 PM
Creation date
1/22/2025 1:36:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0521537
PE
2371 - UST FACILITY - 1702 COMPLIANT
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2615 W GRANT LINE RD TRACY 95304
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Secondary Containment Testing Report Form <br /> 8. SUMP/UDC TEST (continued) <br /> Test Method Developed by ❑ Manufacturer ® Industry Standard ❑ Professional Engineer <br /> Test Type ❑ Pressure ❑ Vacuum ® Hydrostatic <br /> Test Equipment Used: Caldwell Level Change Indicator <br /> Sump/UDC ID UDC 9-10 UDC 11-12 <br /> Sump Manufacturer Unknown Unknown <br /> Sump Depth (inches) 30 30 <br /> Sump Bottom to Top of 9 9 <br /> Highest Pipe Penetration <br /> (inches) <br /> Test Start Time 9:55 AM 10:00 AM <br /> Initial Reading 0 0 <br /> Test End Time 10:25 AM 10:30 AM <br /> Final Reading 4.75" 4.75" <br /> Change in Reading 4.75" 4.75" <br /> Pass/Fail Criteria 0 0 <br /> Tightness Test Results ❑ Pass ® Fail ❑ Pass ® Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Sump/UDC ID 87 FILL 91 FILL DIESEL FILL <br /> Sump Manufacturer Unknown Unknown Unknown <br /> Sump Depth (inches) 60 60 60 <br /> Sump Bottom to Top of 0 0 0 <br /> Highest Pipe Penetration <br /> (inches) <br /> Test Start Time 12:30 PM 12:40 PM 12:50 PM <br /> Initial Reading 0 0 0 <br /> Test End Time 1:00 PM 1:10 PM 1:20 PM <br /> Final Reading 0 0 0 <br /> Change in Reading 0 0 0 <br /> Pass/Fail Criteria 0 0 0 <br /> Tightness Test Results ® Pass ❑ Fail ® Pass ❑ Fail ® Pass ❑ Fail ❑ Pass ❑ Fail <br /> Additional copies of this page may be attached. <br /> All tests marked "Fail'and any repairs made before or during the tightness test must be described in <br /> the COMMENTS section. <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.