SAN JOAQUIN <br />COUNTY <br />- <br />SCOPE OF WORK <br />Environmental Health Department <br />REQUIRED PERMIT TYPE <br />DISPENSERS <br />Installation of additional dispensers or relocation of existing dispensers <br />(3) UST Retrofit - Full Permit <br />Dispenser replacement with conversion frame <br />(4) UST Retrofit - Minor Plan Check <br />Dispenser replacement due to structural damage (e.g. vehicular incident) <br />(4) UST Retrofit - Minor Plan Check <br />Dispenser replacement with no vehicular damage and no conversion <br />frames <br />(5) UST Retrofit - No Fee Permit <br />Conversion frame installation or replacement <br />(4) UST Retrofit - Minor Plan Check <br />Deflector plate installation or replacement <br />(5) UST Retrofit - No Fee Permit <br />Dispenser repair or reprogramming <br />(6) No UST Retrofit Permit Needed <br />Filter replacement <br />(6) No UST Retrofit Permit Needed <br />FLOATS AND CHAINS *effective 1/1/26 repair or replacement of floats and chains will no longer be allowed* <br />Float -and -chain repair or replacement - "like for like" <br />(5) UST Retrofit - No Fee Permit <br />Shear valve repair or replacement when connected to a float -and -chain <br />device <br />(5) UST Retrofit - No Fee Permit <br />Shear valve repair or replacement when NOT connected to a float -and- <br />chain device <br />(6) No UST Retrofit Permit Needed <br />Chain tightening or adjustment <br />(6) No UST Retrofit Permit Needed <br />Removal of floats -and -chains and switching to sensors <br />(3) UST Retrofit - Full Permit <br />Filling float -and -chain cups/holes or removal of barriers when floats were <br />previously removed under permit when not including sensor installation <br />(4) UST Retrofit - Minor Plan Check <br />SPILL CONTAINERS <br />Direct bury spill container replacement <br />(3) UST Retrofit - Full Permit <br />Direct bury double wall spill container "primary bucket" replacement — no <br />breaking of concrete <br />(3) UST Retrofit - Full Permit <br />Spill container in a tank top sump - "like for like" <br />(5) UST Retrofit - No Fee Permit <br />Spill container in a tank top sump - not "like for like" <br />(4) UST Retrofit - Minor Plan Check <br />Spill container drain valve replacement <br />(6) No UST Retrofit Permit Needed <br />Vapor bucket replacement <br />(6) No UST Retrofit Permit Needed <br />Equipment replacement or modification inside a spill container that <br />reduces capacity <br />(5) UST Retrofit - No Fee Permit <br />Riser piping repair or replacement in a sump on tanks installed prior to <br />7/1/03 <br />(6) No UST Retrofit Permit Needed <br />OTHER <br />Breaking concrete over tank systems, including over piping <br />(5) UST Retrofit - No Fee Permit <br />Turbine replacement <br />(6) No UST Retrofit Permit Needed <br />*test leak detector for functionality after work is done <br />Air pollution control equipment installation, repair, or replacement - <br />contact the San Joaquin Valley Air Pollution Control District <br />(6) No UST Retrofit Permit Needed <br />4 of 4 REVISED 7/24/2025 <br />