Laserfiche WebLink
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />October 21, 2024 <br /> Facility Address: <br /> 1002 FRONTAGE RD, RIPON <br /> Facility Name: <br /> GAS & SHOP <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />records signed, kept for 3 years. <br />OBSERVATION: The facility failed to keep written procedures and records of inspections and tests, including integrity <br />tests, for at least three years. Copies of inspection and testing records for 2021-2024 per inspection schedule <br />described on page 33-34 of the SPCC Plan were not found on site. <br />REGULATION GUIDANCE: 112.7(e), Conduct inspections and tests required by this part in accordance with written <br />procedures that you or the certifying engineer develop for the facility. You must keep these written procedures and a <br />record of the inspections and tests, signed by the appropriate supervisor or inspector, with the SPCC Plan for a period <br />of three years. Records of inspections and tests kept under usual and customary business practices will suffice for <br />purposes of this paragraph. 112.8(c)(6) Test or inspect each aboveground container for integrity on a regular schedule <br />and whenever you make material repairs. <br />CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures <br />developed in the Spill Prevention, Control, and Countermeasure (SPCC) Plan. Records of these inspections and tests <br />must be signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three years. <br />Immediately locate a copy of all inspection and testing records for the last three years, maintain them on-site, and <br />submit copies to the EHD. <br />This is a repeat violation (Class 2) Violation. <br />Code of Fed Regulations 112.7(a)(1), 112.8(c)(8) 4010056 - SPCC adequately describes overfill prevention methods, <br />and devices/systems used for each container. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to adequately describe the <br />overfill prevention methods, including a description of the devices or systems in place for each container to prevent <br />overfills and failed to include an adequate discussion of facility's conformance with the requirements listed in §112.7. <br />REGULATION GUIDANCE: 112.7 (a)(1) Include a discussion of your facility's conformance with the requirements listed <br />in this part [§112.7]. 112.8 (c)(8) Engineer or update each container installation in accordance with good engineering <br />practice to avoid discharges. <br />You must provide at least one of the following devices : <br />(i) High liquid level alarms with an audible or visual signal at a constantly attended operation or surveillance station. In <br />smaller facilities an audible air vent may suffice . <br />(ii) High liquid level pump cutoff devices set to stop flow at a predetermined container content level . <br />(iii) Direct audible or code signal communication between the container gauger and the pumping station. <br />(iv) A fast response system for determining the liquid level of each bulk storage container such as digital computers , <br />telepulse, or direct vision gauges. If you use this alternative, a person must be present to monitor gauges and the <br />overall filling of bulk storage containers. <br />(v) You must regularly test liquid level sensing devices to ensure proper operation . <br />CORRECTIVE ACTION: The SPCC plan shall adequately address overfill prevention methods, including a description <br />of the devices or systems in place for each container to prevent overfills. Provide proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 59 <br />Code of Fed Regulations 112.8(c)(8), 25270.4.5(a) 4030019 - Each container installation has a liquid level sensing <br />device.. <br /> 60 <br />FA0000650 PR0516198 SC001 10/21/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 12 of 16 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD