Laserfiche WebLink
Sampling and Analysis Plan for Phase II Environmental Site Assessment <br /> 125 North Stockton Street, Lodi,CA 95240 <br /> One laboratory-supplied blank Laboratory prepared organic-free VOCs-3 samples (assuming 3 <br /> Trip Blanks per cooler containing samples for blank to assess potential days spent on-site collecting soil <br /> VOC analyses. contamination during sample samples) <br /> container shipment and storage. <br /> 3.2.5 Background Samples <br /> Background soil and soil vapor samples are not proposed.The Property is located in an area with <br /> a history of residential, commercial, and institutional uses which are associated with similar <br /> potential contaminants of concern for soil (petroleum hydrocarbons, lead, and PAHS). Therefore, <br /> identifying a reliable location for a background sample is not considered feasible. In addition, <br /> VOCs in soil vapor beneath the Property will be considered a concern regardless of whether the <br /> source is one or more on-Site releases, or one or more off-site or background sources for <br /> contamination. <br /> 3.2.6 Decontamination Procedures and Waste Management <br /> Reusable sampling equipment will be decontaminated prior to use and between locations using <br /> non-phosphate detergent and a triple-rinse method. Equipment rinsate and soil cuttings will be <br /> stored in 55-gallon steel drums pending profiling and disposal. Stantec will collect representative <br /> waste samples and coordinate for removal and disposal of investigation-derived waste. <br /> 3.3 Inadvertent Discovery Planning <br /> The minimally intrusive nature of the proposed subsurface soil assessment makes discovery of <br /> cultural artifacts or human remains highly unlikely. However, In the unlikely event that cultural <br /> artifacts or human remains are discovered during completion of the work, Stantec will follow <br /> relevant protocols as described in the Inadvertent Discovery Plan included as Appendix A. <br /> 3.4 Reporting <br /> Following receipt of final laboratory analytical results, Stantec will validate and verify chemical <br /> data as described in the Master QAPP and prepare a summary report for submittal to the City of <br /> Lodi.The report will include the following elements. <br /> • A description of field sampling activities; <br /> • A scaled site plan illustrating borehole and sampling locations; <br /> • Tabulated summaries of analytical data screened against appropriate risk-based criteria; <br /> • Analysis of chemical testing results as they relate to 1) evidence of a release, and 2) risk to <br /> human health or the environment; <br /> • Recommendations, as appropriate; and, <br /> • Discussion of any deviations from the procedures described in this SAP. <br /> 5 Stantec 13 <br />