My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BRANDT
>
12505
>
2800 - Aboveground Petroleum Storage Program
>
PR0526901
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:07:49 PM
Creation date
9/10/2025 2:06:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0526901
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0018219
FACILITY_NAME
FORD CONSTRUCTION COMPANY - BRANDT YARD
STREET_NUMBER
12505
Direction
E
STREET_NAME
BRANDT
STREET_TYPE
RD
City
LOCKEFORD
Zip
95237
APN
05132010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
12505 E BRANDT RD LOCKEFORD 95237
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />6/2/2025 <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />May 19, 2025 <br /> Facility Address: <br /> 12505 E BRANDT RD, LOCKEFORD <br /> Facility Name: <br /> FORD CONSTRUCTION COMPANY - BRANDT <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.7(a)(3)(i) 4010041 - SPCC Plan addresses the type of oil and storage capacity for all <br />fixed and portable containers. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to address the type of oil and <br />storage capacity for each of the following containers: <br />- a 10,000-gallon red diesel portable aboveground storage tank (AST), located adjacent to the water tanks. <br />- a 12,000-gallon red diesel portable AST located off -site at the time of inspection, according to Dave Coveney, on-site <br />manager. <br />REGULATION GUIDANCE: The SPCC plan shall include: (i) The type of oil in each fixed container and its storage <br />capacity. For mobile or portable containers, either provide the type of oil and storage capacity for each container or <br />provide an estimate of the potential number of mobile or portable containers, the types of oil, and anticipated storage <br />capacities. <br />CORRECTIVE ACTION: The SPCC Plan shall properly address the type and storage capacity of all fixed and portable <br />and/or mobile containers, as required. Submit proof of correction to the EHD. <br />This is (Minor) Violation. <br /> 15 <br />Code of Fed Regulations 112.7(a)(3), 25270.4.5(a) 4010015 - SPCC contains an adequate facility diagram. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to include an adequate facility <br />diagram. The facility diagram was missing the location and contents of the following ASTs : <br />- 480-gallon 15W/40 oil tank <br />- 240-gallon hydraulic fluid tank <br />- 240-gallon transmission fluid tank <br />- 360-gallon waste oil tank <br />REGULATION GUIDANCE: (3) Describe in your Plan the physical layout of the facility and include a facility diagram, <br />which must mark the location and contents of each fixed oil storage container and the storage area where mobile or <br />portable containers are located. The facility diagram must identify the location of and mark as “exempt” underground <br />tanks that are otherwise exempted from the requirements of this part under § 112.1(d)(4). The facility diagram must <br />also include all transfer stations and connecting pipes, including intra-facility gathering lines that are otherwise <br />exempted from the requirements of this part under § 112.1(d)(11). <br />CORRECTIVE ACTION: Ensure that the SPCC plan includes a complete facility diagram, including the location and <br />contents of the above-mentioned tanks. Provide proof of correction to the EHD. <br />This is (Minor) Violation. <br /> 16 <br />Code of Fed Regulations 112.7(e), 112.8(c)(6) 4010021 - Written Inspection/testing procedures kept, inspection/testing <br />records signed, kept for 3 years. <br />OBSERVATION: The SPCC plan states the facility performs monthly inspections based upon the STI SP001. <br />However, the facility failed to provide monthly inspection records upon request. <br /> 57 <br />FA0018219 PR0526901 SC001 05/19/2025 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 8 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD