Laserfiche WebLink
Geosynte& <br /> consultants <br /> 5. QUALITY CONTROL SAMPLES <br /> QC samples will be employed and monitored during implementation of the Work Plan. <br /> Laboratory QC samples are initiated and monitored by the laboratory as part of the testing <br /> procedures. Field QC samples will be collected in the field and used to evaluate the <br /> quality of the field sampling activities. Not all field and laboratory QC sample types <br /> apply to all proposed laboratory analytical methods. <br /> 5.1 Trip Blanks <br /> Trip blanks are used to detect VOC contamination during sample shipping and handling. <br /> Trip blanks will consist of 40-milliliter(mL)volatile organic analysis(VOA)vials of de- <br /> ionized water that are prepared by the laboratory. Trip blanks will be transported to the <br /> sampling site, accompany the respective sampling containers during field activities, and <br /> be returned to the laboratory with the respective samples. Trip blanks will be submitted <br /> and analyzed at the frequency of one per sample cooler containing samples for analysis <br /> of VOCs. The trip blanks will be analyzed for VOCs only. <br /> 5.2 Field Duplicate Samples <br /> Field duplicate samples will be collected to assess the precision and overall quality of the <br /> sampling and analytical procedures. Field duplicate samples are collected at the same <br /> time and from the same source as the primary sample. Field duplicate samples will be <br /> collected, numbered, packaged, and sealed in the same manner as other samples, and <br /> submitted blind to the laboratory for identical analyses as the primary sample. The <br /> frequency for field duplicate sample collection and analysis for the project is 1 per 10 <br /> primary groundwater samples. The relative percent differences (RPDs) between the <br /> results of the field duplicate and the primary groundwater sample should be less than or <br /> equal to 30%. <br /> 5.3 Field Equipment Rinsate Blanks <br /> Field equipment rinsate blanks (equipment blanks) are used to evaluate decontamination <br /> procedures of sampling equipment. The samples consist of contaminant-free water that is <br /> poured over decontaminated, non-dedicated sampling equipment and collected into <br /> required sampling containers. Non-dedicated sampling equipment may include the <br /> drilling shoe (for grab groundwater sampling) or sample pumps. One field equipment <br /> rinsate blanks will be collected per day for each analysis sampled for on that day, when <br /> non-dedicated sampling equipment is used.These samples are submitted to the laboratory <br /> for identical analyses as the other samples. <br /> Quality Assurance Project Plan 8 30 April 2025 <br />