Table 1.Comments on Forward Landfill •'�IaRC1 ❑I S <br /> Review of Draft[Tentative]WDR and MRP <br /> Forward Landfill <br /> Item WDR SectionrTopic Comment <br /> Residential Domestic Wells listed under Correction Action Program in the <br /> Tentative WDR.These wells are currently sampled under directive in CAO and <br /> the data indicate that they have not been affected by a release from the <br /> Findings Table 3 16 26 Monitoring Network landfill and should not be included in the more frequent and rigorous reporting <br /> program proposed in the Tentative WDR.Footnote 6 addresses the corrective <br /> action wells.Can language be added to remove these wells from the WDRs if <br /> 1 they are removed from the corrective action program? <br /> Can a sentence be added to note that this entire area will eventually be <br /> Findings 85 24 34 LAA converted to a borrow area and once this occurs,the WDR and MRP <br /> 2 requirements for cannery waste will no longer apply? <br /> Can a sentence be added noting that any new sampling requirements for the <br /> 4 Findings 105 31 41 LAA LAA area are effective starting January 1,2024? <br /> See comment under Item 4.Also,can a statement be added regarding what <br /> happens if there is a conflict between WDRs and Salt and Nitrate Control <br /> Program and if both WDRs and Salt and Nitrate Program need to be followed <br /> 5 Findings 114 33-35 1 43-45 Salt and Nitrate Control Program following Forward's enrollment in the Salt and Nitrate Control Program? <br /> 6 Specifications Table 16 44 54 Inert Wastes Please allow inert wastes to be disposed in surface impoundments <br /> Clarify that this applies to extracted leachate being surface applied or <br /> reinjected into existing Class III WMUs and does not apply to leachate formed <br /> within the WMU.Also,27CCR 20340 states leachate shall be returned to unit <br /> Discharge from which it came.Can leachate from Class III units be discharged to Class II <br /> 7 Specifications Table 16 45 55 Leachate units? <br /> Please clarify if a WMU refers to a single cell,like WMU FU-19,or is it the <br /> Discharge broader sense of the word,such as a contiguous Class II landfill cell or an area <br /> 8 Specifications B.6 46 56 Landfill Gas Condensate that drains to a particular leachate impoundment. <br /> Discharge Please allow cannery muds to be discharged to dry in bermed areas within <br /> 9 Specifications B.7 46 56 Cannery Mud WMUs and then disposed within the WMU,as described in the Findings <br /> 10 Time Schedule Table 17,Item 5 55 65 Updated Multi-Phase Closure Dates Please allow due date to be modified to March 30,2024 <br /> 11 Time Schedule Table 17,Item 6 55 65 Sensitive Receptor Survey Please allow due date to be modified to March 30,2024 <br /> 12 Attachment E Item 2 61 71 Primary Composite Liner The primary liner is not a composite liner <br /> 13 Attachment E Item 2 61 71 LCRS The LCRS also serves as a leak detection layer <br />