Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - HW LQG Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Transit America Services Inc 1020 E Alpine AVE, Stockton June 05 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> This is (Class 2)Violation. <br /> 28 CA Code of Regulations 66262.34(f)3030007-Labeled all containers or portable tanks containing hazardous waste. <br /> OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. The containers were: <br /> -55-gallon drum containing paper filters in the Hazardous Waste collection area with a hazardous waste label missing <br /> the hazardous properties and physical state <br /> -55-gallon drum containing metal filters in the Hazardous Waste collection area with a hazardous waste label missing <br /> the accumulation start date. <br /> REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the words <br /> "Hazardous Waste", name and address of generator, hazardous properties, physical state, composition (contents), <br /> accumulation start date <br /> CORRECTIVE ACTION: Immediately label the containers as required for hazardous waste. Provide a corrective <br /> action statement and supporting documentation to the San Joaquin County Environmental Health Department(EHD) <br /> within 30 days. <br /> This is a repeat violation (Class 2) Violation. <br /> 40 CA Code of Regulations 66265.192(k)3010026-Written hazardous waste tank system assessment meets all <br /> requirements. <br /> OBSERVATION: This facility has hazardous waste tanks with incomplete tank assessments. <br /> -Results of a leak test, internal inspection, or other tank system integrity examination including the type of integrity <br /> examination performed (i.e. ultrasonic, internal examination, volumetric tank test, pipeline pressure test)were not <br /> included for the 2,000-gallon capacity waste antifreeze tank and the 2,000-gallon capacity used oil tank. <br /> -The"preset volume"or"preset level"at which the audible/visual alarms are triggered for overfill prevention were not <br /> evaluated for the 2,000-gallon capacity waste antifreeze tank and the 2,000-gallon capacity used oil tank. <br /> REGULATION GUIDANCE:Title 22 California Code of Regulations section 66265.191 Assessment of Existing Tank <br /> System's Integrity. The Tank Assessment shall address, at a minimum, the items outlined in Title 22 California Code <br /> of Regulations section 66265.191(b)(5)(B). The full list of requirements for the Tank Assessment are included in <br /> 66265.191(g). <br /> CORRECTIVE ACTION: Have a qualified Professional Engineer update the tank assessment and add the missing <br /> sections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. Provide a copy of the updated assessment,when available. <br /> This is(Class 2)Violation. <br /> 43 CA Code of Regulations 66265.195 3030029-Conducts/documents daily inspections of hazardous waste tank <br /> system. <br /> OBSERVATION: The facility has a hazardous waste tank and multiple daily tank inspection record checklists were <br /> observed to be incomplete. <br /> -Both question 6(compatibility of tank and hazardous contents)and question 7(accumulation start date is less than <br /> 90 days from the current date)were left blank on the 1/6/25, 1/21/25 and the 4/10/25 daily inspection checklists. <br /> -Questions 2 through 7 were left blank on the 2/24/23 daily inspection checklist. <br /> FA0022230 PR0538718 SCO01 06/05/2025 <br /> EHD Rev.12/06/2021 Page 5 of 7 CP22-HW LOG OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />