Laserfiche WebLink
SAN JOAQUIN Environmental Health Department <br /> —COUNTY <br /> C:eatness grows here. <br /> CP26 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#039 12285 E FREMONT ST, STOCKTON Auqust 4, 2026 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 2 23 CCR 16 2613(a)(1)-(4) and (6), and (b); HSC 6.7 25286 2011009 - Complete and accurate application for a permit to <br /> operate a UST has been submitted and maintained <br /> OBSERVATION: The most current copy of the UST response plan was not on site. The UST response plan on site did <br /> not have contact information for the responsible person(s) <br /> REGULATION GUIDANCE: §2690. (a)An application for an operating permit must be submitted to the Unified Program <br /> Agency by the owner or operator. The application must include the following information, to the extent such information is <br /> known to the applicant: (8) Monitoring program in accordance with section 2650 including the facility: (A) Monitoring plan; <br /> (B) Monitoring site plan, and; (C) Response plan. <br /> § 2691. (d)A paper or electronic copy of the permit and all conditions and attachments, including the monitoring <br /> program, must be readily accessible at the facility. <br /> CORRECTIVE ACTION: Immediately obtain the most current copies of the UST response plan retain it on site. <br /> This is a Repeat(Class 2)Violation. <br /> 3 23 CCR 16 2613(a)(3) and (b), 2650(a), (b), and (e) 2011011 - Facility has submitted and maintains a complete and <br /> accurate UST Monitoring Plan <br /> OBSERVATION: Owner/Operator failed to submit and/or maintain a complete and accurate UST Monitoring Plan. <br /> 1)The monitoring plan lists that the UDC Panel Manufacturer is Veeder-Root and the UDC Panel Model # is TLS-350. <br /> But the UDC sensors are Veeder Root standalone sensors which are not connected to Veeder Root Panels. The <br /> monitoring panel section for the UDCs should be blank. <br /> 2)The 87 Pipe Monitoring Leak Sensor Manufacturer and Sensor Model is listed as Veeder Root 0794380-208. On site <br /> was observed as a PMP 63228. <br /> REGULATION GUIDANCE: § 2650(b) Owners or operators must submit a monitoring plan for approval by the Unified <br /> Program Agency which establishes: (2)The release detection methods and release detection equipment, identified by <br /> name and model, to be used for performing the monitoring <br /> CORRECTIVE ACTION: <br /> 1) Submit a complete and accurate UST Monitoring Plan and maintain copy onsite for review. <br /> 2) The sensor was replaced during the inspection from a PMP 63228 to a Veeder Root 208. This now matches the <br /> monitoring plan in CERS. <br /> This is a Repeat(Class 2)Violation. <br /> 4 23 CCR 16 2613(a)(4) and (b), 2650(a), (c), and (e) 2011012 - Facility has submitted and maintains a monitoring site <br /> plan <br /> OBSERVATION: Owner/Operator failed to submit and maintain a monitoring site plan for approval by the UPA. The <br /> monitoring site plan used two maps to meet requirements. Per State Water Board only one map should be uploaded to <br /> meet requirements of§ 2650(c). <br /> REGULATION GUDIANCE: § 2650(c) Monitoring Site Plan —Owners or operators must submit a monitoring site plan for <br /> approval by the Unified Program Agency. The monitoring site plan must include, but is not limited to, the following: (1)A <br /> scaled diagram indicating the layout of the tank(s)and piping to the extent known, including containment sumps; (2) <br /> Locations of all release detection equipment; and (3) If applicable, each vacuum, pressure, or hydrostatic interstitial <br /> monitoring zone. <br /> CORRECTIVE ACTION: Submit and maintain a monitoring site plan and ensure a copy is maintained on site. <br /> This is a (Minor)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 4 of 6 FA0001659 PR0231111 4682260 8/4/2026 <br /> CP26-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />