INSTALLATION INSTRUCTIONS <br /> FREEDOM & ❑ETAILS <br /> FLOOD V F ICI T MODEL FFV-1608 <br /> FLOOD VENT <br /> Freedom Flood Vent .-4-19 <br /> 800—5 07— 152 7 <br /> www.freedomfloodvent.com <br /> 16 114" FZD �2', <br /> INSTALLATION INSTRUCTIONS <br /> SCALE BAR <br /> 0 1" <br /> 1 . PREPARE A CLEAN 16.25" WIDE BY 8.25" HIGH ROUGH OPENING i ------ --------r -- ��--��- �r i 01 =25mm <br /> (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. i IF THIS BAR IS NOT <br /> AS , ADJUST <br /> ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE THAN 12" ABOVE THE FINISHED GRADE. ti SCALESO CWN CORDINGLY <br /> 2. APPLY A BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK 2025 COPYRIGHT BY <br /> OF THE FLANGE ON THE VENT FRAME. (FIG. 2) 8114 Ro JTOSTE ENGINEERING <br /> i THIS DRAWING AND/OR <br /> 3. POSITION THE FRAME INTO THE OPENING AND PUSH THE VENT COMPLETELY IN UNTIL. THE FRAME ; DOCUMENT SHALE NOT BE <br /> IS FLUSH WITH THE WALL. j j ALTERED, REPRODUCED, <br /> CHANGED, TRANSFERRED, <br /> 4. RE—CHECK THAT FRAME IS SQUARE. ; ; OR COPIED WITHOUT <br /> 5. VENT DOOR COMES WITH COVER INSTALLED. a a d a a a a a o a JTO TEN CONSENT FROM <br /> a p JTOSTE ENGINEERING. <br /> IF NATURAL AIR VENTILATION IS DESIRED, REMOVE THE COVER BY PUSHING THE RIVETS __— UNAUTHORIZED USE of <br /> THIS DRAWING AND/OR <br /> FROM BEHIND AND PLACE IN STORAGE. FOR USE IN COLDER TEMPERATURES LEAVE COVER ATTACHED. DOCUMENT BY A THIRD <br /> PARTY WILL HOLD JTOSTE <br /> ENGINEERING HARMLESS. <br /> FRONT VIEW WITH COVER INSTALLED <br /> 0 <br /> Know whays below. <br /> �¢¢ Call before you dig. <br /> DETAILED SPECIFICATIONS: ���° _---___�..�__________�.��____ _ ...�.. cn <br /> Uj <br /> MATERIAL: POLYCARBONATE PLASTIC p� o OPERATION FLOOD: AUTOMATIC NON—POWERED ACTIVATION AND OPERATION ; °o p �o Q <br /> VENT REMAINS CLOSED AND LOCKED UNTIL ACTIVATED <br /> INCLUDED REMOVABLE WINTER COVER REQUIRED FOR COLDER CLIMATES <br /> LU LO <br /> °o o° j ~ z a- vn 00 o <br /> LiJQxzQ � Q <br /> INSTALLATION: r_ 0 cr o w I- � U" <br /> SECURED W,/ HURRIBOND ADHESIVE a a v v o a a a a ° a o o m a- W 0 � cr o <br /> HYDROSTATIC RELIEF: 250 SQ. FT PER VENT a- a J o o <br /> VENTILATION. 31 SQ. IN. PER VENT NOTE. VAPOR BARRIER ALLOWS FOR REDUCED VENTILATION a � Of 0 <br /> REQUIREMENTS FLOOD: MINIMUM OF 2 VENTS PER ENCLOSED AREA 0 ao 1-- <br /> MOU NTE❑ ON AT LEAST TWO DIFFERENT WALLS to <br /> COLORS: REAR VIEW SHOWING HOLES IN DOOR (FIG. 2) <br /> BLACK OR WHITE L9 N <br /> Z po °0° <br /> MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY: — a, I <br /> Uj <br /> FEMA, NFIP, ICC, & ASCE Q PO <br /> LO <br /> SUPPORTIVE DOCUMENTS, TB 1 -08, 44CFR 60,3(C)(5), ASCE 24- 14 W v <br /> ICC EVALUATION # ESR-4332 vF CD O <br /> W cv <br /> 1 FLOOD VENTS Z L <br /> N.T.S. <br /> w O <br /> 01F00 <br /> 19 O C3 <br /> Z � Z <br /> W <br /> � W <br /> W � <br /> O � <br /> W <br /> oil � <br /> . � <br /> z <br /> Ma <br /> �o00 E SSloAl <br /> �P�,BERTOT Fyn, <br /> W o oJ' <br /> No. 77,3 <br /> j r <br /> i <br /> CIVIL <br /> OF CA��F��� <br /> SIGNED: 6-29-2025 <br /> SHEET <br /> 5 <br /> 5 OF 11 <br />