My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601127
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LUCERNE
>
6185
>
2600 - Land Use Program
>
SU-2601127
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2026 4:50:36 PM
Creation date
3/3/2026 12:43:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU-2601127
PE
2664 - VARIANCE - FLOOD (VR)
STREET_NUMBER
6185
Direction
W
STREET_NAME
LUCERNE
STREET_TYPE
AVE
City
TRACY
Zip
95304
APN
21309030
CURRENT_STATUS
Closed - Issued
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
6185 W LUCERNE AVE TRACY 95304
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SCOPE OF WORK STRUCTURAL DESIGN NOTES DESIGN NOTES METAL BUILDING <br /> 1. TO PROVIDE STRUCTURAL DESIGN FOR THE MEMBER PROPERTIES MANUFACTURER <br /> PRE-FAB METAL BUILDING PER THE SPECIFIED 1. ALL CONSTRUCTION SHALL BE PROVIDED IN ACCORDANCE 1. THE INTENTION OF ELEVATIONS PROVIDED ON THIS SHEET IS TO INDICATE LOCATION PROPERTY <br /> WITH CBC 2022, IBC 2021, ASCE7-22, OSHA, AISC 360, AISI 100, STRUCTURAL COMPONENTS, DIMENSIONS, AND BUILDING ORIENTATION <br /> DESIGN LOADS, AND APPLICABLE BUILDING MAIN BUILDING <br /> CODES. ANY DISCREPANCIES IN DESIGN LOADS AWS D1.3 CODES AND ALL APPLICABLE LOCAL ONLY. <br /> COLUMN POST (2) TS 2 2" SQ X 14GA <br /> SHALL BE BROUGHT TO THE ATTN. OF THE REQUIREMENTS. 2. ARCHITECTURAL DESIGN REQUIREMENTS ARE NOT COVERED IN THIS PLAN TUBES - STITCH WELDED <br /> ENGINEER OF RECORD. 2. BASE CONNECTIONS SHALL BE PROVIDED AS SHOWN ON SET. THESE DESIGN REQUIREMENTS SHALL BE ADDRESSED IN A SEPARATE END WALL POST TS 2 2" SQ X 14GA TUBE <br /> 2. DOES NOT PROVIDE ANY ARCHITECTURAL, SITE, FOUNDATIONS DETAILS SHEET. ARCHITECTURAL SET BY RESPONSIBLE LICENSED PROFESSIONALS IN lrr� <br /> ZONING, HVAC, ELEC, MECH DESIGN OR 3. ALL MATERIALS IDENTIFIED BY A MANUFACTURER NAME MAY CHARGE, AS NEEDED. ROOF MEMBER TS 2 2" SQ X 14GA TUBE <br /> FOR QUESTIONS, MODIFICATIONS, <br /> REQUIREMENTS. THESE ITEMS MUST BE BE SUBSTITUTED WITH MATERIAL EQUAL OR EXCEEDING 3. ALL EXT WALL SHEATHING SHALL BE: CLASS A RATED 29GA. 3/4" RIB HT - 1 „ REVISIONS OR CORRECTIONS NEEDED <br /> PEAK BRACE TS 2 SQ X 14GA TUBE TO PLANS, PLEASE CONTACT THE <br /> ADDRESSED BY THEIR RESPECTIVE ORIGINAL. GALV OR PAINTED STEEL (FY=80 KSI) OR EQ. METAL BUILDINGS MANUFACTURER <br /> PROFESSIONALS IN CHARGE. 4. ALL SHOP CONNECTIONS SHALL BE WELDED CONNECTIONS. 4. ALL EXT ROOF SHEATHING SHALL BE: CLASS A RATED 29GA. 3/4" RIB HT - LEAN TO LISTED ON PLANS. ENGINEER OF <br /> NO FIELD WELDING IS REQUIRED. 1 �� RECORD REQUIRES AUTHORIZATION <br /> STRUCTURAL DESIGN CRITERIA Q GALV OR PAINTED STEEL (FY=80 KSI) OR EQ. COLUMN POST TS 2 / SQ X 14GA TUBE FROM THE METAL BUILDINGS <br /> PREVAILING CODE: CBC 2022 (IBC 2021) 5. ALL STRUCTURAL FIELD CONNECTIONS SHALL BE #12-14 x 1" 5. LOC OF WALK-IN DOORS OR WINDOWS CAN BE DETERMINED ON SITE AS MANUFACTURER TO MAKE ANY <br /> END WALL POST TS 2 2" SQ X 14GA TUBE CHANGES TO PLANS. <br /> USE GROUP: U SIDS (ESR-2196) OR APPROVED EQUAL. LONG AS THEY FALL BETWEEN BAYS (BETWEEN FULL FRAMES). <br /> CONSTRUCTION TYPE: II - B 6. STEEL SHEATHING SHALL BE 29GA. CORRUGATED GALV. OR 6. PER IBC 1507.4.2 PROVIDE LAP SEALANTS PER MANUFACURER'S ROOF MEMBER (2) TS 2 2" SQ X 14GA SEAL BELOW <br /> RISK CATEGORY: <br /> PAINTED STEEL - MAIN RIB HT. 3/4" (FY=80 KSI) OR EQ. INSTRUCTION AT ROOF SHEATHING LAPS. TUBES - STITCH WELDED <br /> BUILDING FOOTAGE: 2400 SQ-FT 7. SHEATHING CONNECTIONS SHALL BE #12-14 x 3/4" SIDS. ALL STRUCTURES QRoFEss/6�v <br /> NEOPRENE WASHERS ARE REQUIRED. SHEATHING FASTENER SCHEDULE 1 ��° �o�EP ,�� q��, <br /> BASE RAIL TS 2 „ SQ X 14GA TUBE � �� <br /> LOCATION CORNER PANEL SIDE LAPS EDGE LAPS ELSEWHERE <br /> 8. ALL STRUCTURAL LIGHT GAUGE TUBING AND CHANNELS <br /> DEAD LOAD (D) KNEE BRACE TS 2 2" SQ X 14GA TUBE C84908 m <br /> COLLATERAL LOAD 2.00 PSF SHALL BE ASTM A653 (HSLA) GRADE 50 STEEL (Fy = 50 KSI, Fu SPACING 9' C/C MIN. 1 4 2" C/C 9"C/C EXp. 03-31-2026 <br /> = 65 KSI) OR EQUAL. FASTENER TYPE: #12-14 X 1" SELF-DRILL SCREWS (ESR-2196) W/ CONNECTOR SLEEVE TS 2 4" SQ X 12GA TUBE <br /> ROOF LIVE LOAD Lr = 20.00 PSF 9. STRUCTURAL TUBE TS 2 112" x 2 112" x 14GA (0.083") IS NEOPRENE/STEEL WASHER PURLINS 4" X 1" X 14GA HAT �� �fi L, o� <br /> EQUIVALENT TO TS 2 1/4" x 2 1/4" x 12GA (0.109") AND EITHER SPECIAL INSPECTIONS: CHANNEL CA <br /> SNOW LOAD (S) ONE MAY BE USED IN LIEU OF THE OTHER. THE ENGINEERING SEAL COVERS <br /> TS <br /> GROUND SNOW LOAD Pg = 1.00 PSF 10. 12GA IS DEFINED AS 0.109" THICKNESS. 14GA IS DEFINED AS 1. PERIODIC INSPECTION OF POST INSTALLED STRNTEDINTHIUCTURAL SSETOFIGN PLANS. <br /> PRESENTED IN THIS SET OF PLANS. IT <br /> IMPORTANCE FACTOR Is - 1.0 0.083" THICKNESS. 26GA IS DEFINED AS 0.019" THICKNESS. CONCRETE ANCHORS PER ICC-ESR OR BUILDING DOES NOT PROVIDE ANY <br /> 29GA IS DEFINED AS 0.015" THICKNESS. OFFICIAL REQUIREMENTS ARCHITECTURAL, SITE, ZONING, HVAC, <br /> THERMAL FACTOR Ct = 1.2 ELEC, MECH DESIGN OR <br /> 11. GYPSUM BOARD OR DRYWALL FINISH OR ANY BRITTLE BASE REQUIREMENTS. THESE ITEMS MUST <br /> EXPOSURE FACTOR Ce = 1.0 NO ADDITIONAL SPECIAL INSPECTIONS ARE REQUIRED BE ADDRESSED BY THEIR RESPECTIVE <br /> MATERIAL IS NOT CONSIDERED OR ACCOUNTED FOR ON THE PROFFSSIONALSINCHARGE. <br /> ROOF SLOPE FACTOR Cs = 1.0 FOR THIS STRUCTURE UNLESS EXPLICITLY REQUIRED <br /> FLAT ROOF SNOW LOAD Pf = 0.84 PSF DESIGN CRITERIA OF THIS STRUCTURE, U.N.O. BY THE BUILDING OFFICIAL. <br /> LEGEND PROJECT TITLE PROJECT <br /> SLOPED ROOF SNOW LOAD Ps = 0.84 PSF 1 2 3 4 LOCATION <br /> WALK-IN DOORS (REF. DOOR MFG) <br /> WIND LOAD (W) Vult = 95 MPH I 12 <br /> DESIGN WIND SPEED WN WINDOWS I 31 <br /> EXPOSURE C _ <br /> SEISMIC LOAD (E) H HEADER 1 <br /> SS 1.130 12 12 1.33� �1.33 I �J <br /> S1 0.340 NOTE: ANY DOOR OR WINDOW W CD <br /> > O <br /> SDs 0.970 DESIGN INFORMATION IS NOT =N Q Q m <br /> SD1 0.600 COVERED IN THIS PLAN SET AND <br /> W <br /> DESIGN CATEGORY D 6, _ Z <br /> SHALL BE ADDRESSED -1 <br /> SITE CLASS D (DEFAULT) (Do Q <br /> IMPORTANCE FACTOR le = 1.0 BY OTHERS. � o Z W U <br /> END LAP ASD LOAD COMBINATIONS: <br /> MAX. 4 1/2C/C �'� Q <br /> PQ Strength (ASCE 2.4): L <br /> SIDE LAP STITCH 1 00 <br /> GRADE <br /> SCREW . QP 2. D + 0.6W <br /> MIN. (1) #12 SDS <br /> 3. D + 0.75 (Lr or 0.7S) + 0.75 (0.6W) 3'-0" e 12'-0" 3'-0" e 5'-0" 14'-0" 5'-0" 3'-0" 12'-0" 3'-0" <br /> .� <br /> 46 PATTERN 4. .6D 0+ .6W <br /> ( ± 9" C/C) 5. 0 0 + 0.7 + 0.7EH FRONT END WALL ELEVATION <br /> 46 PATTERN PURLIN <br /> ( ± 9 C/C) 6. D + 0.525Ev + 0.525EH + 0.1S SCALE: 3/16" : 1' <br /> @ CORNER / EDGE 7. 0.61D - 0.7Ev + 0.7EH 4 3 2 1 <br /> SHEATHING FASTENER PATTERN Service: <br /> SCALE: 1/4" : 1' D + 0.5 (Lr or S) + Wa I 31 LH <br /> REVISIONS <br /> I # DATE DRAWN CHECKED <br /> 36" I I BY BY <br /> 9" STRUCTURAL DRAWING INDEX 12 12 <br /> 1 04�16�2025 NG JH <br /> CODE CONTENT 1.33� �1.33 <br /> END WALLS ELEVATIONS <br /> 3% (4 �, ff C/C) PATTERN s-1 & SPECIFICATIONS =N <br /> SIDE WALLS ELEVATIONS & FRAME CN <br /> �� S-2 LAYOUT PLAN o <br /> 29GA. - 3/4 RIB PROFILE QO CD <br /> S-3 FOUNDATION PLAN & DETAILS 1--1 = <br /> SCALE : 1 " 1 ' <br /> S-4 FRAME ELEVATIONS & DETAILS WIN WN WIN TITLE SHEET <br /> FRAME WALLS ELEVATIONS & END WALLS <br /> S-5 DETAILS ELEVATIONS <br /> S-6 LEAN TO FRAME WALLS GRADE & SPECIFICATIONS <br /> ELEVATIONS & DETAILS <br /> 00 <br /> 12'_0" 3'-0" 3'-7Y" 2'-0 12'-92" 2'-0 3'-72" 7'-11" 2'-0 8'-12„ NUMBER SHEET <br /> REAR END WALL ELEVATION S - 1 <br /> SCALE: 3/16" : 1' <br /> c� <br />
The URL can be used to link to this page
Your browser does not support the video tag.