Laserfiche WebLink
IA <br />INTERIOR <br />ARCHITECTS <br />Al 41 - Roof Details <br />Enlarged fixed ladder plan is revised. <br />Roof ladder section is revised. <br />Al 40-Roof Plan <br />Location of roof hatch is revised. <br />Rooftop walking pads are added. <br />Interior Architect#, Inc., a California corporation in AK, AL, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, MT, NE, NH, OK, SC, SD, TN, TX, UT, VA, VT, WA, Wl, WV, WY / Interior Architects, P.C., a New York professional services corporation in AL, AR, DC, <br />GA, ID, IA, ME, MD, MS, NM, NV, NY, NC, ND, OH, OR, PA / Interior Architects, P.C. dba Interior Architects, professional corporation in R| / Interior Architects New Jersey PC, a New Jersey profess onal corporation in NJ and CT / Intenor Architects. PC. <br />dba IA Interior Architects in II / Interior Architects, PC., license *AA26001062 in Fl / Interior Architects, P.C. dba Interior Architects, a professional corporation in IA / Interior Architects, Inc., a Colorado corporation in CO, Ml / IA Interior Architects Inc., <br />"Holder of Certificate of Practice, Architectura' Institute of British Columbia, Alberta Association of Architects and Ontario Association of Architects" in British Columbia, Alberta, and Ontario, Canada / Interior Architects Inc. - UK Branch (t/a IA UK) / Ono IA <br />Design UK Limited / One IA Design limited <br />A203 - Reflected Ceiling & Unistrut Plan <br />Diffusers are moved at POS. <br />Track light at Beverage is moved closer to the counter. <br />Hood is revised. <br />A202 - Reflected Ceiling Plan - Dimensioned <br />BDP/UPS equipment is revised. <br />Diffusers are moved at POS. <br />Roof hatch location is moved. <br />X6.1 exterior light is added at the rear door. <br />Light fixture schedule is revised, Bl, B2 E2 and X6.1 quantities <br />are changed. <br />Mopus ceiling is revised. <br />Track light at Beverage is moved closer to the counter. <br />Al 32 - Equipment Schedule <br />CO2 alarm and strobe description is revised. <br />Mopus shelf tag and length are revised. <br />Backflow preventer is removed from the schedule. <br />A201 - Reflected Ceiling Plan <br />Bypass distribution panel note is added at Office. <br />BDP/UPS equipment is revised. <br />Diffusers are moved at POS. <br />Roof hatch location is moved. <br />X6.1 exterior light is added at the rear door. <br />Light fixture schedule is revised, Bl, B2 E2 and X6.1 quantities <br />are changed. <br />Mopus ceiling is revised. <br />Track light at Beverage is moved closer to the counter.