My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
701
>
2300 - Underground Storage Tank Program
>
PR0231059
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/29/2026 8:14:41 PM
Creation date
4/3/2026 11:12:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231059
PE
2361 - UST FACILITY
FACILITY_ID
FA0002512
FACILITY_NAME
EXPRESS FUEL & MART
STREET_NUMBER
701
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734311
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
701 E DR MARTIN LUTHER KING JR BLVD STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN AMENDED Environmental Health Department <br /> COUNTY— 6/10/2026 <br /> CP26 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> EXPRESS FUEL & MART 1701 E DR MARTIN LUTHER KING JR BLVD, STO June 10, 2026 <br /> 38 23 CCR 16 2613(c)(10) and (13) 2011003- Records of release detection monitoring and maintenance properly <br /> maintained for 36 months (TCR 9d) <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br /> -The 6/20/24 repair Monitoring System Certification test results <br /> -The 11/30/23 repair Monitoring System Certification test results <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; <br /> (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings <br /> of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings <br /> and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the last <br /> three years on site. <br /> This is a Repeat(Class 2)Violation. <br /> 40 23 CCR 16 2613(e) 2011002 - Installation, repair, lining, integrity, calibration, and release records maintained for life of <br /> UST <br /> OBSERVATION: Records of installation, repairs, linings, integrity certification, tank calibration charts, and/or <br /> unauthorized release reports were not kept onsite, or offsite if approved by the UPA, for the life of the UST. <br /> -The following were not available for review at the time of inspection: installation test results, manufacturer checklists <br /> and manuals, tank calibration charts (overfill charts), and as-built drawings. <br /> REGULATION GUIDANCE: 2613(e)The following records must be maintained by the owner or operator on site, or off <br /> site at a readily accessible location if approved by the Unified Program Agency, for the life of the underground storage <br /> tank system: (1) Installation records including, but not limited to: (A) Installation test results; (B) Manufacturer checklists <br /> and manuals; and (C)As-built drawings. (2) Records of repairs, including inspection reports and structural integrity <br /> certifications associated with interior lining; (3)Tank calibration charts; and (4) Unauthorized release reports. <br /> CORRECTIVE ACTION: Immediately locate and maintain these records onsite and submit copies to the UPA within 30 <br /> days. <br /> This is a (Minor)Violation. <br /> 44 23 CCR 16 2643(c) and (d); HSC 6.7 25288 2031031 - Facility has corrected all previously cited violations <br /> OBSERVATION: Owner/Operator did not correct violations cited in the inspection report within 30 days of receiving an <br /> inspection report from either the UPA or special inspector. <br /> -An inspection was last done on 6/11/25 and an inspection report was issued identifying information to be submitted to <br /> bring this site into compliance. This information was required to be submitted by 7/11/25. This information has not been <br /> fully received resulting in a non-compliant status for this facility. <br /> REGULATION GUIDANCE: (c) For each minor violation issued by the Unified Program Agency or the Board, the owner <br /> or operator must correct the violation in accordance with section 25404.1.2 of the Health and Safety Code. (d) For all <br /> other violations issued or recommendations contained in an inspection report by the Unified Program Agency, the Board, <br /> or a special inspector, the owner or operator must correct the violation, implement the recommendation, or demonstrate <br /> why the recommendation should not be implemented in accordance with section 25288 of the Health and Safety Code. <br /> CORRECTIVE ACTION: Correct all violations cited on the inspection report provided by the UPA or special inspector <br /> within 30 days (for minor violations) or 60 (for all other violations)of receiving an inspection report. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 6 of 7 FA0002512 PR0231059 4659133 6/10/2026 <br /> CP26-UST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page