COMPLIANCE INFO_2026
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2026 7:53:58 PM
Creation date
4/29/2026 4:16:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231161
PE
2361 - UST FACILITY
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
07917039
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
8660 LOWER SACRAMENTO RD STOCKTON 95210
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of Underground Storage Tank Program violations that <br />have not been addressed for fast and easy mart #103 as of August 13, 2026. <br />Open violations from June 09, 2026 inspection <br />OBSERVATION: Owner/Operator failed to have a properly qualified service technician test leak detection equipment <br />every 12 months. <br /> <br />- The Diesel Line Leak Detector has not been tested every 12 months, it was last tested on 5/22/2025 and is now 1 <br />month late. <br />REGULATION GUIDANCE: The line leak detector test is required once every 12 months. <br />CORRECTIVE ACTION: Immediately schedule the required testing and provide 72 hours notification to the EHD. <br /> <br />Describe actions taken or will be taken to correct violation: <br />¨ This violation will be corrected by (date): ¨ This violation was corrected <br />¨ Supporting documents included <br />Open violations from May 06, 2026 inspection <br />OBSERVATION: Owner/Operator failed to properly install, calibrate, operate and/or maintain leak detection equipment <br />in accordance with manufacturer's specifications. <br />- The Diesel LLD was unable to be tested due to electrical issues according to service technician Zane Nimmo. <br />REGULATION GUIDANCE: "Failure of the release detection equipment to be installed, calibrated, operated, or <br />maintained in accordance with manufacturer's specifications. <br />CORRECTIVE ACTION: Properly install, calibrate, operate and/or maintain leak detection equipment in accordance <br />with manufacturer's specifications. Submit verification of compliance. <br /> <br />Describe actions taken or will be taken to correct violation: <br />¨ This violation will be corrected by (date): ¨ This violation was corrected <br />¨ Supporting documents included <br />Page 1 of 2
The URL can be used to link to this page
Your browser does not support the video tag.